| Manufacturer part number (MPN) | 6EP3434-3SB00-0AX0 EAN / GTIN: 4025515156253 Sales unit: pcs Type of the power supply network: 3-phase AC Supply voltage at AC — minimum rated value: 400 V Supply voltage at AC — maximum rated value: 500 V Supply voltage at AC — initial value: 320 V Supply voltage at AC — full-scale value: 550 V Buffering time for rated value of the output current in the event of power failure minimum: 5 ms Operating condition of the mains buffering: at Vin = 400/500 V Line frequency: 50/60 Hz Input current — at rated input voltage 400 V: 0.7 A Input current — at rated input voltage 500 V: 0.6 A Current limitation of inrush current at 25 °C maximum: 50 A Duration of inrush current limiting at 25 °C — typical: 20 ms I2t value maximum: 0.9 A²·s Fuse protection type in the feeder: three-poled coupled circuit breaker from 3 A characteristic C to 16 A characteristic C or circuit breaker 3RV2011-1EA10 (setting 3 A) or 3RV2711-1ED10 (UL 489) Output voltage at DC rated value: 24 V Output voltage — at output 1 at DC rated value: 24 V Adjustable output voltage: 24 ... 28 V Relative overall tolerance of the voltage: 3 % Relative control precision of the output voltage — on slow fluctuation of input voltage: 0.2 % Relative control precision of the output voltage — on slow fluctuation of ohm loading: 0.3 % Residual ripple — maximum: 150 mV Voltage peak — maximum: 240 mV Voltage peak — typical: 30 mV Display version for normal operation: Green LED for 24 V OK Type of signal at output: Signal contact (signal load capacity: 5 mA) for DC OK Response delay maximum: 1.5 s Voltage increase time of the output voltage — typical: 210 ms Voltage increase time of the output voltage — maximum: 500 ms Output current — rated value: 10 A Output current — rated range: 0 ... 10 A; +60 ... +70 °C: Derating 3%/K Supplied active power typical: 240 W Number of parallel-switched equipment resources for increasing the power: 2 Efficiency in percent: 90 % Power loss [W] — at rated output voltage for rated value of the output current typical: 27 W Power loss [W] — during no-load operation maximum: 3 W Relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical: 0.2 % Relative control precision of the output voltage load step of resistive load 50/100/50 % typical: 0.5 % Relative control precision of the output voltage at load step of resistive load 10/90/10 % typical: 1.5 % Setting time — load step 10 to 90% typical: 1 ms Setting time — load step 90 to 10% typical: 1 ms Design of the overvoltage protection: < 32 V General information — typical: 12.2 A Enduring short circuit current RMS value — typical: 12.5 A Galvanic isolation: Output voltage: SELV, ES1 (IEC 62368-1), DVC As (IEC 61204-7) Leakage current — maximum: 0.8 mA Leakage current — typical: 0.4 mA Protection class IP: IP20 Ambient temperature — during operation: -25 ... +70 °C; with natural convection Ambient temperature — during transport: -40 ... +85 °C Ambient temperature — during storage: -40 ... +85 °C General information — at input: L1, L2 |