| Manufacturer part number (MPN) | 6EP3346-7SB00-3AX0 EAN / GTIN: 4025515155225 Sales unit: pcs Type of the power supply network: 1-phase AC or DC Supply voltage at AC — minimum rated value: 120 V Supply voltage at AC — maximum rated value: 240 V Supply voltage at AC — initial value: 85 V Supply voltage at AC — full-scale value: 264 V Supply voltage at DC: 110 ... 240 V Input voltage at DC: 85 ... 275 V Overvoltage overload capability: 300 V AC for 30 s Buffering time for rated value of the output current in the event of power failure minimum: 25 ms Operating condition of the mains buffering: at Vin = 240 V Line frequency: 50/60 Hz Input current — at rated input voltage 120 V: 4.3 A Input current — at rated input voltage 240 V: 2.3 A Current limitation of inrush current at 25 °C maximum: 11 A Fuse protection type: 10 A Fuse protection type in the feeder: Circuit breaker from 6 A characteristic B to 16 A characteristic C or circuit breaker 3RV2011-1HA10 (setting 8A) or 3RV2711-1HD10 (UL 489) Number of outputs: 1 Output voltage at DC rated value: 48 V Output voltage — at output 1 at DC rated value: 48 V Adjustable output voltage: 48 ... 56 V; max. 480 W (576 W up to 45°C) Relative overall tolerance of the voltage: 3 % Relative control precision of the output voltage — on slow fluctuation of input voltage: 0.3 % Relative control precision of the output voltage — on slow fluctuation of ohm loading: 0.2 % Voltage peak — maximum: 40 mV Voltage peak — typical: 20 mV Display version for normal operation: Green LED for 48 V OK Type of signal at output: Electronic contact (NO contact, contact rating 30 V DC/0.1 A) for DC O.K. or diagnostic interface Behavior of the output voltage when switching on: Overshoot of Vout < 2 % Response delay maximum: 0.5 s Voltage increase time of the output voltage — typical: 200 ms Output current — rated value: 10 A Output current — rated range: 0 ... 10 A; 12 A up to +45°C; +60 ... +70 °C: Derating 3%/K Supplied active power typical: 480 W Short-term overload current — on short-circuiting during the start-up typical: 15 A Short-term overload current — at short-circuit during operation typical: 15 A Number of parallel-switched equipment resources for increasing the power: 2 Efficiency in percent: 95.8 % Power loss [W] — at rated output voltage for rated value of the output current typical: 21 W Power loss [W] — during no-load operation maximum: 2.5 W Relative control precision of the output voltage at load step of resistive load 10/90/10 % typical: 3 % Setting time — load step 10 to 90% typical: 5 ms Setting time — load step 90 to 10% typical: 5 ms Setting time — maximum: 5 ms Design of the overvoltage protection: < 60 V Design of short-circuit protection — typical: 15 A Overcurrent overload capability — in normal operation: overload capability 150 % Iout rated up to 5 s/min Galvanic isolation: Output voltage: SELV, ES1 (IEC 62368-1), DVC As (IEC 61204-7) Leakage current — maximum: 3.5 mA Protection class IP: IP20 Ambient temperature — during operation: -30 ... +70 °C; with natural convection a monotonically increasing start-up from -25 °C, safe start-up from -40 °C Ambient temperature — during transport: -40 ... +85 °C Ambient temperature — during storage: -40 ... +85 °C Type of electrical connection — at input: L1/+ |