| Manufacturer part number (MPN) | 6EP3344-7SB00-3AX0 EAN / GTIN: 4025515155201 Sales unit: pcs Type of the power supply network: 1-phase AC or DC Supply voltage at AC — minimum rated value: 120 V Supply voltage at AC — maximum rated value: 240 V Supply voltage at AC — initial value: 85 V Supply voltage at AC — full-scale value: 264 V Supply voltage at DC: 110 ... 240 V Input voltage at DC: 85 ... 275 V Overvoltage overload capability: 300 V AC for 30 s Buffering time for rated value of the output current in the event of power failure minimum: 46 ms Operating condition of the mains buffering: at Vin = 240 V Line frequency: 50/60 Hz Input current — at rated input voltage 120 V: 2.2 A Input current — at rated input voltage 240 V: 1.2 A Current limitation of inrush current at 25 °C maximum: 6 A Fuse protection type: 5 A Fuse protection type in the feeder: Circuit breaker from 4 A characteristic C/6 A characteristic B to 10 A characteristic C or circuit breaker 3RV2011-1EA10 (setting 4 A) or 3RV2711-1ED10 (UL 489) Number of outputs: 1 Output voltage at DC rated value: 48 V Output voltage — at output 1 at DC rated value: 48 V Adjustable output voltage: 48 ... 56 V; max. 240 W (288 W up to 45°C) Relative overall tolerance of the voltage: 3 % Relative control precision of the output voltage — on slow fluctuation of input voltage: 0.1 % Relative control precision of the output voltage — on slow fluctuation of ohm loading: 0.1 % Voltage peak — maximum: 60 mV Voltage peak — typical: 40 mV Display version for normal operation: Green LED for 48 V OK Type of signal at output: Electronic contact (NO contact, contact rating 30 V DC/0.1 A) for DC O.K. or diagnostic interface Behavior of the output voltage when switching on: Overshoot of Vout < 2 % Response delay maximum: 0.5 s Voltage increase time of the output voltage — typical: 250 ms Output current — rated value: 5 A Output current — rated range: 0 ... 5 A; 6 A up to +45°C; +60 ... +70 °C: Derating 3%/K Supplied active power typical: 240 W Short-term overload current — on short-circuiting during the start-up typical: 6 A Short-term overload current — at short-circuit during operation typical: 6 A Number of parallel-switched equipment resources for increasing the power: 2 Efficiency in percent: 93.9 % Power loss [W] — at rated output voltage for rated value of the output current typical: 15 W Power loss [W] — during no-load operation maximum: 2.4 W Relative control precision of the output voltage at load step of resistive load 10/90/10 % typical: 1 % Setting time — load step 10 to 90% typical: 4 ms Setting time — load step 90 to 10% typical: 4 ms Setting time — maximum: 6 ms Design of the overvoltage protection: < 60 V Design of short-circuit protection — typical: 6 A Overcurrent overload capability — in normal operation: overload capability 150 % Iout rated up to 5 s/min Galvanic isolation: Output voltage: SELV, ES1 (IEC 62368-1), DVC As (IEC 61204-7) Leakage current — maximum: 3.5 mA Protection class IP: IP20 Ambient temperature — during operation: -30 ... +70 °C; with natural convection a monotonically increasing start-up from -25 °C, safe start-up from -40 °C Ambient temperature — during transport: -40 ... +85 °C Ambient temperature — during storage: -40 ... +85 °C Type of electrical connection — at input: L1/+ |