| Manufacturer part number (MPN) | 6EP3332-7SB00-0AX0 EAN / GTIN: 4025515155140 Sales unit: pcs Type of the power supply network: 1-phase AC or DC Supply voltage at AC — minimum rated value: 120 V Supply voltage at AC — maximum rated value: 240 V Supply voltage at AC — initial value: 85 V Supply voltage at AC — full-scale value: 264 V Supply voltage at DC: 120 ... 240 V Input voltage at DC: 110 ... 275 V Overvoltage overload capability: 300 V AC for 30 s Buffering time for rated value of the output current in the event of power failure minimum: 150 ms Operating condition of the mains buffering: at Vin = 240 V Line frequency: 50/60 Hz Input current — at rated input voltage 120 V: 1.1 A Input current — at rated input voltage 240 V: 0.6 A Current limitation of inrush current at 25 °C maximum: 32 A Fuse protection type: 3.15 A Fuse protection type in the feeder: Circuit breaker from 4 A characteristic C/6 A characteristic B to 16 A characteristic C or circuit breaker 3RV2011-1EA10 (setting 4 A) or 3RV2711-1ED10 (UL 489) Number of outputs: 1 Output voltage at DC rated value: 24 V Output voltage — at output 1 at DC rated value: 24 V Adjustable output voltage: 22.2 ... 26.4 V; max. 60 W Relative overall tolerance of the voltage: 3 % Relative control precision of the output voltage — on slow fluctuation of input voltage: 0.1 % Relative control precision of the output voltage — on slow fluctuation of ohm loading: 0.1 % Residual ripple — maximum: 30 mV Voltage peak — maximum: 30 mV Voltage peak — typical: 20 mV Display version for normal operation: Green LED for 24 V OK Behavior of the output voltage when switching on: Overshoot of Vout approx. 3 % Response delay maximum: 1 s Voltage increase time of the output voltage — typical: 100 ms Output current — rated value: 2.5 A Output current — rated range: 0 ... 2.5 A; +60 ... +70 °C: Derating 2.5%/K Supplied active power typical: 60 W Short-term overload current — on short-circuiting during the start-up typical: 2.5 A Short-term overload current — at short-circuit during operation typical: 2.5 A Efficiency in percent: 89 % Power loss [W] — at rated output voltage for rated value of the output current typical: 7 W Power loss [W] — during no-load operation maximum: 0.8 W Relative control precision of the output voltage at load step of resistive load 10/90/10 % typical: 3 % Setting time — load step 10 to 90% typical: 1 ms Setting time — load step 90 to 10% typical: 1 ms Setting time — maximum: 2 ms Design of the overvoltage protection: < 32 V Design of short-circuit protection — typical: 3.1 A Galvanic isolation: Output voltage: SELV, ES1 (IEC 62368-1), DVC As (IEC 61204-7) Leakage current — maximum: 3.5 mA Protection class IP: IP20 Ambient temperature — during operation: -25 ... +70 °C; with natural convection Ambient temperature — during transport: -40 ... +85 °C Ambient temperature — during storage: -40 ... +85 °C Type of electrical connection — at input: L1/+ |