| Manufacturer part number (MPN) | 3RB3113-4NE0 |
| EAN / GTIN | 4011209749078 |
| Sales unit | pcs |
| Product type designation | 3RB3 |
| Size of contactor can be combined company-specific | S00 |
| Power loss [W] for rated value of the current at AC in hot operating state | 0.1 W |
| General technical data — per pole | 0.03 W |
| Insulation voltage with degree of pollution 3 at AC rated value | 690 V |
| Surge voltage resistance rated value | 6 kV |
| Shock resistance | 15 g / 11 ms |
| General technical data — according to IEC 60068-2-27 | 15 g / 11 ms; Signaling contact 97 / 98 in position "Tripped": 9g / 11 ms |
| Vibration resistance | 1 … 6 Hz, 15 mm; 6 … 500 Hz, 20 m/s²; 10 cycles |
| Thermal current | 1.25 A |
| Recovery time after overload trip — with automatic reset typical | 3 min |
| Installation altitude at height above sea level maximum | 2 000 m |
| Ambient temperature — during operation | -25 ... +60 °C |
| Ambient temperature — during storage | -40 ... +80 °C |
| Ambient temperature — during transport | -40 ... +80 °C |
| Temperature compensation | -25 ... +60 °C |
| Relative humidity during operation | 10 ... 95 % |
| Number of poles for main current circuit | 3 |
| Adjustable current response value current of the current-dependent overload release | 0.3 ... 1.25 A |
| Operating voltage — rated value | 690 V |
| Operating voltage — for remote-reset function at DC | 24 V |
| Operating voltage — at AC-3e rated value maximum | 690 V |
| Operating frequency rated value | 50 ... 60 Hz |
| Operational current rated value | 1.25 A |
| Operational current at AC-3e at 400 V rated value | 1.25 A |
| Operating power — for 3-phase motors at 400 V at 50 Hz | 0.12 ... 0.37 kW |
| Operating power — for AC motors at 500 V at 50 Hz | 0.12 ... 0.55 kW |
| Operating power — for AC motors at 690 V at 50 Hz | 0.18 ... 0.75 kW |
| Number of NC contacts for auxiliary contacts | 1 |
| Number of NO contacts for auxiliary contacts | 1 |
| Operational current of auxiliary contacts at AC-15 — at 24 V | 4 A |
| Operational current of auxiliary contacts at AC-15 — at 110 V | 4 A |
| Operational current of auxiliary contacts at AC-15 — at 120 V | 4 A |
| Operational current of auxiliary contacts at AC-15 — at 125 V | 4 A |
| Operational current of auxiliary contacts at AC-15 — at 230 V | 3 A |
| Operational current of auxiliary contacts at DC-13 — at 24 V | 2 A |
| Operational current of auxiliary contacts at DC-13 — at 60 V | 0.55 A |
| Operational current of auxiliary contacts at DC-13 — at 110 V | 0.3 A |
| Operational current of auxiliary contacts at DC-13 — at 125 V | 0.3 A |
| Operational current of auxiliary contacts at DC-13 — at 220 V | 0.11 A |
| Response time of the grounding protection in settled state | 1 000 ms |
| Full-load current (FLA) for 3-phase AC motor — at 480 V rated value | 1.25 A |
| Full-load current (FLA) for 3-phase AC motor — at 600 V rated value | 1.25 A |
| For short-circuit protection of the main circuit — with type of coordination 1 required | gG: 35 A |
| RK5 | 6 A |
| For short-circuit protection of the main circuit — with type of coordination 2 required | gG: 6 A |
| For short-circuit protection of the main circuit — for short-circuit protection of the auxiliary switch required | fuse gG: 6 A |
| Installation/ mounting/ dimensions — height | 72 mm |
| Installation/ mounting/ dimensions — width | 45 mm |
| Installation/ mounting/ dimensions — depth | 90 mm |
| Type of connectable conductor cross-sections for main contacts — solid | 1x (0.5 ... 4 mm²) |
| Type of connectable conductor cross-sections for main contacts — solid or stranded | 1x (0,5 ... 4 mm²) |
| Type of connectable conductor cross-sections for main contacts — finely stranded with core end processing | 1x (0.5 ... 2.5 mm²) |
| Type of connectable conductor cross-sections for main contacts — finely stranded without core end processing | 1x (0.5 ... 2.5 mm²) |
| For auxiliary contacts — solid | 2x (0.25 ... 1.5 mm²) |
| For auxiliary contacts — solid or stranded | 2x (0,25 ... 1,5 mm²) |
| For auxiliary contacts — finely stranded with core end processing | 2x (0.25 ... 1.5 mm²) |
| For auxiliary contacts — finely stranded without core end processing | 2x (0.25 ... 1.5 mm²) |
| Conducted interference — due to high-frequency radiation according to IEC 61000-4-6 | 10 V in frequency range 0.15 to 80 MHz, modulation 80 % AM with 1 kHz |
| Mounting method | Direct attachment |
| Width | 45 mm |
| Height | 72 mm |
| Depth | 90 mm |
| Number of auxiliary contacts as normally open contact | 1 |
| Number of auxiliary contacts as normally closed contact | 1 |
| Release class | Adjustable |
| Type of electrical connection of main circuit | Spring clamp connection |
| Reset function input | Yes |
| Reset function automatic | Yes |
| Country of origin | Czechia |
| Product family | SIRIUS 3RB3 solid-state overload relay |
| Setting range | 0.32 – 1.25 A |
| Contactor size | S00 |
| Ground-fault detection | Yes, internal |
| Terminal type | Spring-loaded (spring-clamp) |
| Reset | Manual and automatic |