cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Siemens SIRIUS Load feeder fuseless, Direct-on-line starting 400 V AC, Size S00 4.50...6.30 A 230 V AC Spring-type terminal for installation on standard mounting rail Type of coordination 1, Iq = 150 kA 1 NO (contactor) (3RA2110-1GE15-1AP0)

Siemens · Drives & Controllers · Motor Starters · Germany · siemens.com
Part Number
3RA2110-1GE15-1AP0  ·  HS 8536.49
Siemens SIRIUS Load feeder fuseless, Direct-on-line starting 400 V AC, Size S00 4.50...6.30 A 230 V AC Spring-type terminal for installation on standard mounting rail Type of coordination 1, Iq = 150 kA 1 NO (contactor) (3RA2110-1GE15-1AP0)

Siemens 3RA2110-1GE15-1AP0 Direct-on-line start 4.5-6.3A,Ac 230V Spring terminals.

Technical Specifications

Manufacturer part number (MPN)3RA2110-1GE15-1AP0
EAN / GTIN4011209795372
Sales unitpcs
Product brand nameSIRIUS
Product designationDirect (on-line) starter
Design of the productfor DIN-rail or screw mounting
Product type designation3RA21
Manufacturer's article number — of the supplied contactor3RT2015-2AP01
Manufacturer's article number — of the supplied circuit-breakers3RV2011-1GA20
Manufacturer's article number — of the supplied link module3RA2911-2AA00
Size of the circuit-breakerS00
Size of load feederS00
Power loss [W] for rated value of the current — at AC in hot operating state per pole2.6 W
Power loss [W] for rated value of the current — without load current share typical4.2 W
Type of calculation of power loss current-dependentquadratic
Insulation voltage with degree of pollution 3 at AC rated value690 V
Surge voltage resistance rated value6 kV
Degree of protection NEMA ratingother
Shock resistance according to IEC 60068-2-276 g / 11 ms
Mechanical service life (operating cycles) of contactor typical30 000 000
Type of coordination1
Reference code according to IEC 81346-22019: Q
Ambient temperature — during operation-20 ... +60 °C
Ambient temperature — during storage-50 ... +80 °C
Ambient temperature — during transport-50 ... +80 °C
Temperature compensation-20 ... +60 °C
Relative humidity during operation10 ... 95 %
Number of poles for main current circuit3
Design of the switching contactelectromechanical
Adjustable current response value current of the current-dependent overload release4.5 ... 6.3 A
Operating voltage — rated value690 V
Operating voltage — at AC-3 rated value maximum690 V
Operating voltage — at AC-3e rated value maximum690 V
Operating frequency rated value50 ... 60 Hz
Operational current — at AC-3 at 400 V rated value6.3 A
Operational current — at AC-3e at 400 V rated value6.3 A
At AC-3 — at 400 V rated value2 200 W
At AC-3e — at 400 V rated value2 200 W
Type of voltage of the control supply voltageAC
Control supply voltage at AC — at 50 Hz rated value230 V
Control supply voltage at AC — at 60 Hz rated value230 V
Apparent holding power of magnet coil at AC4.2 VA
Apparent holding power of magnet coil at AC — at 50 Hz4.2 VA
Apparent holding power of magnet coil at AC — at 60 Hz3.3 VA
Inductive power factor with the holding power of the coil0.25
Inductive power factor with the holding power of the coil — at 50 Hz0.25
Inductive power factor with the holding power of the coil — at 60 Hz0.25
Product extension auxiliary switchYes
Trip classCLASS 10
Design of the overload releasethermal (bimetallic)
Response value current of instantaneous short-circuit trip unit82 A
Full-load current (FLA) for 3-phase AC motor — at 480 V rated value4.8 A
Full-load current (FLA) for 3-phase AC motor — at 600 V rated value6.1 A
For single-phase AC motor — at 110/120 V rated value0.25 hp
For single-phase AC motor — at 230 V rated value0.75 hp
For 3-phase AC motor — at 200/208 V rated value1.5 hp
For 3-phase AC motor — at 220/230 V rated value2 hp
For 3-phase AC motor — at 460/480 V rated value3 hp
For 3-phase AC motor — at 575/600 V rated value5 hp
Product function short circuit protectionYes
Design of the short-circuit tripmagnetic
Conditional short-circuit current (Iq) — at 400 V according to IEC 60947-4-1 rated value150 000 A
Mounting positionvertical
Fastening methodscrew and snap-on mounting onto 35 mm DIN rail
Installation/ mounting/ dimensions — height198 mm
Installation/ mounting/ dimensions — width45 mm
Installation/ mounting/ dimensions — depth97 mm
For grounded parts — forwards20 mm
For grounded parts — backwards0 mm
For grounded parts — upwards50 mm
For grounded parts — at the side20 mm
For grounded parts — downwards10 mm
For live parts — forwards20 mm
For live parts — backwards0 mm
For live parts — upwards50 mm
For live parts — downwards10 mm
For live parts — at the side20 mm
Type of electrical connection — for main current circuitspring-loaded terminals
Type of electrical connection — for auxiliary and control circuitspring-loaded terminals
Product function suitable for safety functionYes
Touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Protocol is supported — PROFINET IO protocolNo
Protocol is supported — PROFIsafe protocolNo
Protocol is supported AS-Interface protocolNo
Width45 mm
Height198 mm
Depth97 mm
Rated operation power at AC-3, 400 V2.2 kW
Number of command positions1
Suitable for emergency stopYes
Rated operation current Ie4.9 A
Supporting protocol for LONNo
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
External reset possibleNo
Suitable for rail mountingYes
Rated control supply voltage AC 50 Hz230 V
Rated control supply voltage AC 60 Hz230 V
Degree of protection (IP)IP20
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Release classCLASS 10
Type of electrical connection of main circuitSpring clamp connection
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Voltage type for actuatingAC
Rated operation current at AC-3, 400 V4.9 A
Ambient temperature, upper operating limit60 °C
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 1, 480 Y/277 V65000 A
Rated conditional short-circuit current, type 1, 600 Y/347 V30000 A
Coordination class according to IEC 60947-4-3Class 1
Country of originGermany

Properties

MOQ1

Cross-References

Attached Documents