| Manufacturer part number (MPN) | 3RB3016-1NB0 |
| EAN / GTIN | 4011209748545 |
| Sales unit | pcs |
| power loss [W] for rated value of the current at AC in hot operating state | 0.1 W |
| insulation voltage with degree of pollution 3 at AC rated value | 690 V |
| surge voltage resistance rated value | 6 kV |
| maximum permissible voltage for protective separation – in networks with ungrounded star point between auxiliary and auxiliary circuit | 300 V |
| maximum permissible voltage for protective separation – in networks with grounded star point between auxiliary and auxiliary circuit | 300 V |
| maximum permissible voltage for protective separation – in networks with ungrounded star point between main and auxiliary circuit | 600 V |
| maximum permissible voltage for protective separation – in networks with grounded star point between main and auxiliary circuit | 690 V |
| thermal current | 1.25 A |
| recovery time after overload trip – with automatic reset typical | 3 min |
| Net Weight | 0.2 kg |
| installation altitude at height above sea level maximum | 2 000 m |
| ambient temperature – during operation | -25 ... +60 °C |
| ambient temperature – during storage | -40 ... +80 °C |
| ambient temperature – during transport | -40 ... +80 °C |
| temperature compensation | -25 ... +60 °C |
| relative humidity during operation | 10 ... 95 % |
| adjustable current response value current of the current-dependent overload release | 0.3 ... 1.25 A |
| operating voltage – rated value | 690 V |
| operating frequency rated value | 50 ... 60 Hz |
| operational current rated value | 1.25 A |
| operational current at AC-3e at 400 V rated value | 1.25 A |
| operating power – for 3-phase motors at 400 V at 50 Hz | 0.12 ... 0.37 kW |
| operating power – for AC motors at 500 V at 50 Hz | 0.12 ... 0.55 kW |
| operating power – for AC motors at 690 V at 50 Hz | 0.18 ... 0.75 kW |
| operational current of auxiliary contacts at AC-15 – at 24 V | 4 A |
| operational current of auxiliary contacts at AC-15 – at 230 V | 3 A |
| operational current of auxiliary contacts at DC-13 – at 24 V | 2 A |
| operational current of auxiliary contacts at DC-13 – at 110 V | 0.3 A |
| operational current of auxiliary contacts at DC-13 – at 220 V | 0.11 A |
| full-load current (FLA) for 3-phase AC motor – at 480 V rated value | 1.25 A |
| full-load current (FLA) for 3-phase AC motor – at 600 V rated value | 1.25 A |
| Installation/ mounting/ dimensions – height | 79 mm |
| Installation/ mounting/ dimensions – width | 45 mm |
| Installation/ mounting/ dimensions – depth | 73 mm |
| type of connectable conductor cross-sections for main contacts – solid | 1x (0.5 ... 4 mm²), 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 4 mm²) |
| Mounting method | Direct attachment |
| Width | 45 mm |
| Height | 79 mm |
| Depth | 73 mm |
| Number of auxiliary contacts as normally open contact | 1 |
| Number of auxiliary contacts as normally closed contact | 1 |
| Release class | CLASS 10 |
| Type of electrical connection of main circuit | Screw connection |
| Adjustable current range | 0.32–1.25 A |
| Reset function input | No |
| Reset function automatic | Yes |
| Country of origin | Czechia |