| Manufacturer part number (MPN) | 3RA2425-8XF32-2AL2 |
| EAN / GTIN | 4011209838673 |
| Sales unit | pcs |
| Product type designation | 3RA24 |
| Manufacturer's article number — 1 of the supplied contactor | 3RT2026-2AL20 |
| Manufacturer's article number — 2 of the supplied contactor | 3RT2026-2AL20 |
| Manufacturer's article number — 3 of the supplied contactor | 3RT2024-2AL20 |
| Manufacturer's article number — of the supplied RS assembly kit | 3RA2923-2BB2 |
| Manufacturer's article number — of the supplied function module for wye-delta circuits | 3RA2816-0EW20 |
| Size of contactor | S0 |
| Shock resistance at rectangular impulse — at AC | 7,5 g / 5 ms, 4,7 g / 10 ms |
| Shock resistance at rectangular impulse — at DC | 10g / 5 ms, 7,5g / 10 ms |
| Shock resistance with its pulse — at AC | 11,8 g / 5 ms, 7,4 g / 10 ms |
| Shock resistance with its pulse — at DC | 15 g / 5 ms, 10 g / 10 ms |
| Mechanical service life (operating cycles) — of contactor typical | 10 000 000 |
| Mechanical service life (operating cycles) — of the contactor with added auxiliary switch block typical | 10 000 000 |
| Installation altitude at height above sea level maximum | 2 000 m |
| Ambient temperature — during operation | -25 ... +60 °C |
| Ambient temperature — during storage | -55 ... +80 °C |
| Number of poles for main current circuit | 3 |
| Number of NO contacts for main contacts | 3 |
| Number of NC contacts for main contacts | 0 |
| Operating voltage — at AC-3 rated value maximum | 690 V |
| At AC-3 — at 400 V rated value | 40 A |
| At AC-3 — at 500 V rated value | 19 kW |
| At AC-3 — at 690 V rated value | 19 kW |
| Operating frequency — at AC-3 maximum | 1 000 1/h |
| Control supply voltage 1 at AC — at 50 Hz rated value | 230 V |
| Control supply voltage 1 at AC — at 60 Hz rated value | 230 V |
| Operating range factor control supply voltage rated value of magnet coil at AC — at 50 Hz | 0.8 ... 1.1 |
| Operating range factor control supply voltage rated value of magnet coil at AC — at 60 Hz | 0.8 ... 1.1 |
| Apparent pick-up power of magnet coil at AC — at 50 Hz | 164 VA |
| Apparent pick-up power of magnet coil at AC — at 60 Hz | 160 VA |
| Inductive power factor with closing power of the coil — at 50 Hz | 0.72 |
| Inductive power factor with closing power of the coil — at 60 Hz | 0.74 |
| Apparent holding power of magnet coil at AC — at 50 Hz | 23 VA |
| Apparent holding power of magnet coil at AC — at 60 Hz | 19 VA |
| Inductive power factor with the holding power of the coil — at 50 Hz | 0.25 |
| Inductive power factor with the holding power of the coil — at 60 Hz | 0.28 |
| Number of NC contacts for auxiliary contacts — instantaneous contact | 3 |
| Number of NO contacts for auxiliary contacts — instantaneous contact | 3 |
| Contact reliability of auxiliary contacts | < 1 error per 100 million operating cycles |
| Contact rating of auxiliary contacts according to UL | A600 / Q600 |
| For short-circuit protection of the main circuit — with type of coordination 1 required | gG NH 3NA, DIAZED 5SB |
| NEOZED 5SE | 100 A |
| For short-circuit protection of the main circuit — with type of coordination 2 required | gG NH 3NA, DIAZED 5SB |
| NEOZED 5SE | 35 A |
| For short-circuit protection of the main circuit — for short-circuit protection of the auxiliary switch required | fuse gG: 10 A |
| Mounting position | +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface |
| Fastening method | screw and snap-on mounting onto 35 mm DIN rail |
| Installation/ mounting/ dimensions — height | 114 mm |
| Installation/ mounting/ dimensions — width | 135 mm |
| Installation/ mounting/ dimensions — depth | 171 mm |
| With side-by-side mounting — forwards | 6 mm |
| With side-by-side mounting — upwards | 6 mm |
| With side-by-side mounting — downwards | 6 mm |
| With side-by-side mounting — at the side | 6 mm |
| For grounded parts — forwards | 6 mm |
| For grounded parts — upwards | 6 mm |
| For grounded parts — at the side | 6 mm |
| For grounded parts — downwards | 6 mm |
| For live parts — forwards | 6 mm |
| For live parts — upwards | 6 mm |
| For live parts — downwards | 6 mm |
| For live parts — at the side | 6 mm |
| Type of connectable conductor cross-sections for main contacts — solid | 2x (1 ... 10 mm²) |
| Type of connectable conductor cross-sections for main contacts — solid or stranded | 2x (1 ... 10 mm²) |
| Type of connectable conductor cross-sections for main contacts — finely stranded with core end processing | 2x (1 ... 6 mm²) |
| Type of connectable conductor cross-sections for main contacts — finely stranded without core end processing | 2x (1 ... 6 mm²) |
| For auxiliary contacts — solid or stranded | 2x (0.5 ... 2.5 mm²) |
| For auxiliary contacts — finely stranded with core end processing | 2x (0.5 ... 1.5 mm²) |
| For auxiliary contacts — finely stranded without core end processing | 2x (0.5 ... 1.5 mm²) |
| For auxiliary contacts — for AWG cables for auxiliary contacts | 2x (20 ... 14) |
| Protection class IP on the front according to IEC 60529 | IP20 |
| Width | 135 mm |
| Function | Star-delta contactor |
| Height | 114 mm |
| Depth | 171 mm |
| Rated operation power at AC-3, 400 V | 18.5 kW |
| Number of normally open contacts as main contact | 3 |
| Rated operation current Ie at AC-3, 400 V | 40 A |
| Degree of protection (IP) | IP20 |
| Type of electrical connection of main circuit | Spring clamp connection |
| Voltage type for actuating | AC |
| Country of origin | Germany |