| Product type | Rotary switches and key switches |
| Product group | Push buttons and signal units |
| Series | Harmony XB5 |
| Number of posts | 3 pcs |
| REACH SVHC substance above 0.1% | Lead |
| Carbon footprint (EPD) | 0.5158 kg CO2e per pcs |
| Country of origin | France |
| Customs tariff code (EU CN) | 85389099 |
| HS code | 8538.90 |
| Manufacturer part number | ZB5AG03D |
| Range of product | Harmony XB5 |
| Product or component type | Head for key selector switch |
| Device short name | ZB5 |
| Bezel material | Dark grey plastic |
| Mounting diameter | 22 mm |
| Head type | Standard |
| Sale per indivisible quantity | 1 |
| Shape of signaling unit head | Round |
| Type of operator | stay put |
| Operator profile | Black key switch |
| Operator position information | 3 positions +/- 45° |
| Type of keylock | Dom 8D1 |
| Key withdrawal position | Left and center |
| CAD overall width | 29 mm |
| CAD overall height | 29 mm |
| CAD overall depth | 72 mm |
| Product weight | 0.057 kg |
| Mechanical durability | 1000000 cycles |
| Station name | XALD 1...5 cut-outs; XALK 2...5 cut-outs |
| Electrical composition code | C4 for <6 contacts using single and double blocks in front mounting; C5 for <5 contacts using single blocks in front mounting; C6 for <5 contacts using single and double blocks in front mounting; C7 for <4 contacts using single blocks in front mounting; C8 for <4 contacts using single and double blocks in front mounting; C11 for <3 contacts using single blocks in front mounting; C3 for <6 contacts using single blocks in front mounting; SF1 for <3 contacts using single blocks in front mounting; SR1 for <3 contacts using single blocks in rear mounting |
| Device presentation | Basic element |
| Protective treatment | TH |
| Ambient air temperature for storage | -40…70 °C |
| Ambient air temperature for operation | -40…70 °C |
| Overvoltage category | Class II conforming to IEC 60536 |
| IP degree of protection | IP66 conforming to IEC 60529; IP67; IP69; IP69K |
| Enclosure Type | UL type 4X/13 |
| Resistance to high pressure washer | 7000000 Pa at 55 °C, distance : 0.1 m |
| IK degree of protection | IK06 conforming to IEC 50102 |
| Standards | IEC 60947-1; IEC 60947-5-1; UL 508; CSA C22.2 No 14; JIS C8201-5-1; IEC 60947-5-4; JIS C8201-1 |
| Product certifications | DNV; CSA; BV; LROS (Lloyds register of shipping); UL listed |
| Vibration resistance | 5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 30 gn (duration = 18 ms) for half its wave acceleration conforming to IEC 60068-2-27; 50 gn (duration = 11 ms) for half its wave acceleration conforming to IEC 60068-2-27 |
| Warranty (in months) | 18 |
| EAN | 3389110136609 |