LC1DT40FD  ·  HS 8536.49
Schneider LC1D Contactor - TeSys D, 40A, 4P 3389110247879

Schneider LC1D Contactor. Contactors and thermal relays (Electrical Engineering / Components for panels and boxes). Principal data: series TeSys D, current 40 A, number of poles 4P. Supplied under manufacturer part number LC1DT40FD, EAN 3389110247879, HS code 8536.49, country of origin Indonesia.

Technical Specifications

Product typeContactors and thermal relays Product group: Components for panels and boxes Series: TeSys D Current: 40 A Number of poles: 4P REACH SVHC substance above 0.1%: Lead Carbon footprint (EPD): 2.8312 kg CO2e per pcs Country of origin: Indonesia Customs tariff code (EU CN): 85364900 HS code: 8536.49 Manufacturer part number: LC1DT40FD Range: TeSys; TeSys Deca Range of product: TeSys Deca Product or component type: Contactor Device short name: LC1D Contactor application: Resistive load Utilisation category: AC-1 Poles description: 4P [Ue] rated operational voltage: Power circuit: <= 690 V AC 25...400 Hz; Power circuit: <= 300 V DC [Ie] rated operational current: 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit [Uc] control circuit voltage: 110 V DC Compatibility code: LC1D Pole contact composition: 4 NO Protective cover: With [Ith] conventional free air thermal current: 10 A (at 60 °C) for signalling circuit; 40 A (at 60 °C) for power circuit Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 450 A at 440 V for power circuit conforming to IEC 60947 Rated breaking capacity: 450 A at 440 V for power circuit conforming to IEC 60947 [Icw] rated short-time withstand current: 50 A 40 °C - 10 min for power circuit; 120 A 40 °C - 1 min for power circuit; 240 A 40 °C - 10 s for power circuit; 380 A 40 °C - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit Associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1; 63 A gG at <= 690 V coordination type 1 for power circuit; 40 A gG at <= 690 V coordination type 2 for power circuit Average impedance: 2 mOhm - Ith 40 A 50 Hz for power circuit Power dissipation per pole: 3.2 W AC-1 [Ui] rated insulation voltage: Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified; Power circuit: 690 V conforming to IEC 60947-4-1 Overvoltage category: III Pollution degree: 3 [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947 Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 Mechanical durability: 30 Mcycles Electrical durability: 1.4 Mcycles 40 A AC-1 at Ue <= 440 V Control circuit type: DC standard Coil technology: Built-in bidirectional peak limiting diode suppressor Control circuit voltage limits: 0.1...0.25 Uc (-40…70 °C):drop-out DC; 0.7...1.25 Uc (-40…60 °C):operational DC; 1...1.25 Uc (60…70 °C):operational DC Inrush power in W: 5.4 W (at 20 °C) Hold-in power consumption in W: 5.4 W at 20 °C Operating time: 20 ±20 % ms opening; 63 ±15 % ms closing Time constant: 28 ms Maximum operating rate: 3600 cyc/h at 60 °C Connections - terminals: Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 1 2.5…16 mm² - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: solid without cable end Tightening torque: Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2; Power circuit: 1.8 N.m - on screw clamps terminals - with screwdriver flat Ø 6 mm; Power circuit: 1.8 N.m - on screw clamps terminals - with screwdriver Philips No 2; Power circuit: 1.8 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 Auxiliary contact composition: 1 NO + 1 NC Auxiliary contacts type: type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 Signalling circuit frequency: 25...400 Hz minimum switching voltage: 17 V for signalling circuit minimum switching current: 5 mA for signalling circuit Insulation resistance: > 10 MOhm for signalling circuit Non-overlap time: 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact Mounting support: Plate; Rail Standards: CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1; IEC 60335-1 Product certifications: DNV; GL; CCC; LROS (Lloyds register of shipping); RINA; BV; GOST; UL; CSA; CB IP degree of protection: IP20 front face conforming to IEC 60529 Protective treatment: TH conforming to IEC 60068-2-30 Climatic withstand: conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat Permissible ambient air temperature around the device: -40…60 °C; 60…70 °C with derating Operating altitude: 0...3000 m Fire resistance: 850 °C conforming to IEC 60695-2-1 Flame retardance: V1 conforming to UL 94 Mechanical robustness: Vibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (8 Gn for 11 ms) Height: 91 mm Width: 45 mm Depth: 107 mm Product weight: 0.425 kg Warranty (in months): 18 EAN: 3389110247879

Properties

MOQ1

Cross-References

Attached Documents