Schneider LC1D Contactor - TeSys D, 40A, 3P

Schneider Electric · Electrical Components · Contactors · France · se.com
Part Number
LC1D40A6BD  ·  HS 8536.41
Schneider LC1D Contactor - TeSys D, 40A, 3P

Schneider LC1D Contactor. Contactors and thermal relays (Electrical Engineering / Components for panels and boxes). Principal data: series TeSys D, current 40 A, number of poles 3P. Supplied under manufacturer part number LC1D40A6BD, EAN 3389119408615, HS code 8536.41, country of origin France.

Technical Specifications

Product typeContactors and thermal relays Product group: Components for panels and boxes Series: TeSys D Current: 40 A Number of poles: 3P Carbon footprint (EPD): 3.9724 kg CO2e per pcs Country of origin: France Customs tariff code (EU CN): 85364190 HS code: 8536.41 Manufacturer part number: LC1D40A6BD Range: TeSys; TeSys Deca Range of product: TeSys Deca Product or component type: Contactor Device short name: LC1D Contactor application: Resistive load; Motor control Utilisation category: AC-3; AC-3e; AC-1; AC-4 Poles description: 3P [Ue] rated operational voltage: Power circuit: <= 690 V AC 25...400 Hz; Power circuit: <= 300 V DC [Ie] rated operational current: 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit; 40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 40 A (at <60 °C) at <= 440 V AC AC-3e for power circuit [Uc] control circuit voltage: 24 V DC Motor power kW: 11 kW at 220/230 V AC 50/60 Hz (AC-3); 18.5 kW at 380/400 V AC 50/60 Hz (AC-3); 22 kW at 415/440 V AC 50/60 Hz (AC-3); 22 kW at 500 V AC 50/60 Hz (AC-3); 30 kW at 660/690 V AC 50/60 Hz (AC-3); 11 kW at 220/230 V AC 50/60 Hz (AC-3e); 18.5 kW at 380/400 V AC 50/60 Hz (AC-3e); 22 kW at 415/440 V AC 50/60 Hz (AC-3e); 22 kW at 500 V AC 50/60 Hz (AC-3e); 30 kW at 660/690 V AC 50/60 Hz (AC-3e); 9 kW at 400 V AC 50/60 Hz (AC-4) Motor power hp: 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors; 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 3 hp at 115 V AC 50/60 Hz for 1 phase motors; 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors Compatibility code: LC1D Pole contact composition: 3 NO Protective cover: With [Ith] conventional free air thermal current: 10 A (at 60 °C) for signalling circuit; 60 A (at 60 °C) for power circuit Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 800 A at 440 V for power circuit conforming to IEC 60947 Rated breaking capacity: 800 A at 440 V for power circuit conforming to IEC 60947 [Icw] rated short-time withstand current: 320 A 40 °C - 10 s for power circuit; 720 A 40 °C - 1 s for power circuit; 72 A 40 °C - 10 min for power circuit; 165 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit Associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1; 80 A gG at <= 690 V coordination type 1 for power circuit; 80 A gG at <= 690 V coordination type 2 for power circuit Average impedance: 1.5 mOhm - Ith 60 A 50 Hz for power circuit Power dissipation per pole: 2.4 W AC-3; 5.4 W AC-1; 2.4 W AC-3e [Ui] rated insulation voltage: Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified; Power circuit: 690 V conforming to IEC 60947-4-1 Overvoltage category: III Pollution degree: 3 [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947 Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 Mechanical durability: 10 Mcycles Electrical durability: 0.7 Mcycles 60 A AC-1 at Ue <= 440 V; 1.5 Mcycles 40 A AC-3 at Ue <= 440 V; 1.5 Mcycles 40 A AC-3e at Ue <= 440 V Control circuit type: DC standard Coil technology: Built-in bidirectional peak limiting diode suppressor Control circuit voltage limits: 0.1...0.3 Uc (-40…70 °C):drop-out DC; 0.75...1.25 Uc (-40…60 °C):operational DC; 1...1.25 Uc (60…70 °C):operational DC Inrush power in W: 19 W (at 20 °C) Hold-in power consumption in W: 7.4 W at 20 °C Operating time: 50 ±15 % ms closing; 20 ±20 % ms opening Time constant: 34 ms Maximum operating rate: 3600 cyc/h at 60 °C Connections - terminals: Control circuit: lugs-ring terminals - external diameter: 8 mm; Power circuit: lugs-ring terminals - external diameter: 16.5 mm Tightening torque: Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5; Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5; Power circuit: 6 N.m - on lugs-ring terminals hexagonal screw head 10 mm M6; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2; Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 Auxiliary contact composition: 1 NO + 1 NC Auxiliary contacts type: type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 Signalling circuit frequency: 25...400 Hz minimum switching voltage: 17 V for signalling circuit minimum switching current: 5 mA for signalling circuit Insulation resistance: > 10 MOhm for signalling circuit Non-overlap time: 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact Mounting support: Rail; Plate Standards: EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; CSA C22.2 No 14; UL 60947-4-1; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; IEC 60335-1:Clause 30.2 Product certifications: CCC; UL; CB Scheme; CSA; CE; UKCA; Marine; EAC IP degree of protection: IP20 front face conforming to IEC 60529 Protective treatment: TH conforming to IEC 60068-2-30 Climatic withstand: conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat Permissible ambient air temperature around the device: -40…60 °C; 60…70 °C with derating Operating altitude: 0...3000 m Fire resistance: 850 °C conforming to IEC 60695-2-1 Mechanical robustness: Vibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (10 Gn for 11 ms) Height: 122 mm Width: 55 mm Depth: 120 mm Product weight: 0.925 kg Warranty (in months): 18 EAN: 3389119408615

Properties

MOQ1

Cross-References

Attached Documents