cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Schneider Electric energy sensor, PowerTag Rope 600A 3P/3P+N top and bottom position A9MEM1591

Schneider Electric · Sensors & Instrumentation · Energy Meters · France · se.com
Part Number
A9MEM1591  ·  HS 9030.33
Schneider Electric energy sensor, PowerTag Rope 600A 3P/3P+N top and bottom position A9MEM1591

Schneider Electric A9MEM1591 PowerTag - 3P - Flexible - Divisible - Max.. 600 A - Wireless - Energisensor.

Technical Specifications

Manufacturer part number (MPN)A9MEM1591
EAN / GTIN3606481595294
Sales unitpcs
Package quantity7 pcs
Number of poles3P
Range of productPowerLogic
Product namePowerTag R600
Product or component typeEnergy sensor
Poles3P; 3P + N
Maximum current [Imax]600 A
[Ib] Basic current100 A
Starting current400 mA
Saturation current1200 A
Product specific applicationEnergy management; Overload alarm; Power factor; Load monitoring; Circuit monitoring
Concentrator compatibilityEcoStruxure Panel Server Entry; EcoStruxure Panel Server Universal; EcoStruxure Panel Server Advanced; PowerLogic T300; Harmony Hub; Acti9 PowerTag Link; Acti9 PowerTag Link HD
Range compatibilityMasterpact MasterPact MTZ for switch disconnector; Masterpact MasterPact NW; Masterpact MasterPact NT; Compact NS Compact NS100; Compact NS Compact NS250; Compact NS Compact NS400; Acti9; TeSys
Type of measurementActive and reactive energy; Apparent energy; Active and reactive power; Apparent power; Current; Voltage; Power factor; Internal temperature; Frequency
Accuracy classClass 1 active energy conforming to IEC 61557-12; Class 2 reactive energy conforming to IEC 61557-12; Class 2 apparent energy conforming to IEC 61557-12; Class 1 active power conforming to IEC 61557-12; Class 2 reactive power conforming to IEC 61557-12; Class 2 apparent power conforming to IEC 61557-12; Class 1 current conforming to IEC 61557-12; Class 0.5 voltage conforming to IEC 61557-12; Class 1 power factor conforming to IEC 61557-12; Class 0.5 frequency conforming to IEC 61557-12
Metering typeActive energy E -a- IN/OUT 0...281 x 10exp(9) kWh at total per phase; Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at partial per phase; Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at 3-phase total; Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at 3-phase partial; Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at total per phase; Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at partial per phase; Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at 3-phase total; Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at 3-phase partial; Apparent energy E -apA- 0...281 x 10exp(9) kVAh at total per phase; Apparent energy E -apA- 0...281 x 10exp(9) kVAh at partial per phase; Apparent energy E -apA- 0...281 x 10exp(9) kVAh at 3-phase total; Apparent energy E -apA- 0...281 x 10exp(9) kVAh at 3-phase partial; Active power P, P1, P2, P3; Reactive power Q, Q1, Q2, Q3; Apparent power S, S1, S2, S3; Current I1, I2, I3; Calculated neutral current; Voltage U12, U23, U31; Voltage V1N, V2N, V3N; Frequency 45...65 Hz; Power factor at per phase; Power factor at total
Mounting locationTop or bottom
Mounting supportBusbar; Cables
Product destinationSwitchboard
Event managementVoltage loss with measured current at voltage loss
Transmission support mediumRadio frequency 2.4…2.4835 GHz conforming to IEEE 802.15.4
Emission power10 mW
Form factorRope
Mounting modeClip-on (DIN rail)
Electrical connection (voltage sensing & power supply)Removable spring terminal block
Cable cross section1 rigid cable 0.2…1.5 mm² without cable end; 1 stranded cable 0.2…2.5 mm² without cable end; 1 stranded cable 0.25…1.5 mm² with cable end
Wire stripping length11 mm
Cable length1 m for sensor
current sensor diameterClosed: 100 mm
supply voltage100...277 V AC, +/- 20 %, phase to neutral; 173...480 V AC, +/- 20 %, phase to phase
Network frequency50 Hz; 60 Hz
Maximum power consumption3 VA
StandardsIEC 61557-12; IEC 61010-1; ETSI EN 301 489-1; IEC 61010-2-030; IEC 61326-1; ETSI EN 300 328
Product certificationsUL listed; IEC; DNV Marine
Number of 9mm pitches on Din rail2
HeightBase unit: 105 mm
WidthBase unit: 18 mm
DepthBase unit: 67.5 mm
ColourWhite (RAL 9003)
Maximum conductor temperature105 °C
Quality labelsCE
Directives2014/53/EU - radio equipment directive
Operating altitude0...2000 m
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…85 °C
Overvoltage categoryIV conforming to IEC 61010-1
Measurement categoryCategory IV conforming to IEC 61010-2-030
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK05
Pollution degree3
Relative humidity0…95 % at 55 °C conforming to IEC 60721-3-3
Vibration resistance3M4 conforming to IEC 60721-3-3
Electromagnetic compatibilityIndustrial electromagnetic environment conforming to IEC 61326-1; Radiated EMC conforming to ETSI EN 301 489-17; Electromagnetic emission conforming to IEC 62311
environmental characteristicsIndoor use
Number of Units in Package 11
Number of Units in Package 27
Warranty (in months)18
Mounting methodPlug-in technique
ModelMeasurement transformer
Suitable forPurchase
Type of indicationNone
Power consumption3 W
Max. current (Imax)600 A
Width in number of modular spacings1
Type of meterElectronic
Degree of protection (IP)IP20
Energy typeEffective power and reactive power
Tariff typeOne-tariff
Escapement mechanismNo
CalibratedYes
ApprovalDomestic
Pulse outputNone
Pole typeFour conductor
Measurement type load profileNo
EEC40 signatureNo
With lock codeNo
Nominal current (In)600 A
Country of originLatvia

Properties

MOQ1

Cross-References