cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Schneider Electric PM5330 Meter, modbus, up to 31ST H, 256K 2DI/2DO 35 alarms METSEPM5330

Schneider Electric · Electrical Components · Energy Meters · France · se.com
Part Number
METSEPM5330  ·  HS 9028.30
Schneider Electric PM5330 Meter, modbus, up to 31ST H, 256K 2DI/2DO 35 alarms METSEPM5330

Schneider Electric METSEPM5330 Power analyser PM5330. 690V, Modbus and 2 releutg.

Technical Specifications

Manufacturer part number (MPN)METSEPM5330
EAN / GTIN3606480614026
Sales unitpcs
Package quantity12 pcs
RangePowerLogic
Product namePowerLogic PM5000
Product or component typePower meter
Device short namePM5330
Power quality analysisup to the 31st harmonic
Device applicationPower monitoring; Multi-tariff
Type of measurementCurrent; Voltage; Frequency; Power factor; Energy; Active and reactive power
[Us] rated supply voltage90...450 V AC 45...65 Hz; 100...300 V DC
Network frequency50 Hz; 60 Hz
[In] rated current1 A; 5 A
type of network3P + N; 3P; 1P + N
Maximum power consumption in VA11 VA at 415 V
Ride-through time80 ms 120 V AC typical; 100 ms 230 V AC typical; 100 ms 415 V AC typical; 50 ms 125 V DC typical
Display typeMonochrome graphic LCD
Display resolution128 x 128 pixels
Sampling rate64 samples/cycle
Measurement current5…8500 mA
Analogue input typeVoltage (impedance 5 MOhm); Current (impedance <= 0.3 mOhm)
Measurement voltage35…760 V AC 45...65 Hz between phases; 20…400 V AC 45...65 Hz between phase and neutral
Frequency measurement range45…65 Hz
Number of inputs2 digital
Measurement accuracyActive energy +/- 0.5 %; Reactive energy +/- 2 %; Active power +/- 0.5 %; Apparent power +/- 0.5 %; Frequency +/- 0.05 %; Power factor +/- 0.5; Current +/- 0.5 %; Voltage +/- 0.5 %; Apparent energy +/- 0.5 %; Reactive power +/- 2 %
Accuracy classClass 0.5S active energy conforming to IEC 62053-22
Number of outputs2 relay; 2 digital
Information displayedTariff (4)
Communication port protocolModbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V; JBUS
Communication port supportRS485
Data recordingMaintenance logs; Time stamping; Alarm logs; Data logs; Min/max of instantaneous values; Event logs
Memory capacity256 kB
Connections - terminalsVoltage circuit: screw terminal block4; Control circuit: screw terminal block2; Current transformer: screw terminal block6; Input/output circuit: screw terminal block6; Relay output: screw terminal block4; Ethernet network: RJ45 connector
mounting modeFlush-mounted
Mounting supportFramework
StandardsUL 61010-1; IEC 62053-22:2020; IEC 61557-12:2015; EN 50470-3; IEC 60529; IEC 62053-24; EN 50470-1; IEC 62053-23:2020; IEC 62052-11:2020; IEC 62052-31:2015
Product certificationsCE conforming to IEC 61010-1; CULus conforming to UL 61010-1
Width96 mm
Depth72 mm
Height96 mm
Product weight430 g
Electromagnetic compatibilityConducted and radiated emissions class B conforming to EN 55022; Immunity to conducted disturbances - test level: 150 kHz...80 MHz level 4 conforming to IEC 61000-4-6; Electrical fast transient/burst immunity test level 3 conforming to IEC 61000-4-4; Radiated radio-frequency electromagnetic field immunity test level 4 conforming to IEC 61000-4-3; Voltage dips and interruptions immunity test class B conforming to IEC 61000-4-11; Limits for harmonic current emissions class A conforming to IEC 61000-3-2; Electrostatic discharge level 4 conforming to IEC 61000-4-2; Conducted RF disturbances level 3 conforming to IEC 61000-4-6; Magnetic field at power frequency level 4 conforming to IEC 61000-4-8; Immunity to conducted disturbances - test level: 150 kHz...80 MHz conforming to IEC 61000-4-6; Electrical fast transient/burst immunity test conforming to IEC 61000-4-4; Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11; Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3; Electrostatic discharge - test level: 8 kV level 4 conforming to IEC 61000-4-2
IP degree of protectionIP54 display: conforming to IEC 60529; IP30 rear: conforming to IEC 60529
Relative humidity5…95 % at 50 °C non-condensing
Pollution degree2
Ambient air temperature for operation-25…70 °C meter
Ambient air temperature for storage-40…85 °C
Operating altitude2000 m CAT III; 3000 m CAT II
Number of Units in Package 11
Number of Units in Package 212
Number of Units in Package 396
Country of originIN
Warranty (in months)18
Measured value memoryYes
Power factorYes
Suitable for RJ plugNo
Step angle (cos phi)Yes
Harmonics measurementYes
Pulse outputOptical
CalibratedNo
Max. current (Imax)20 A
Measurement type load profileYes
With communication interface KNXNo
With communication interface M-BusNo
With communication interface RS-485Yes
ModelMeasurement transformer
Mounting methodFront mounting
Nominal current (In)5 A
Pole typeThree conductor/four conductor
Apparent powerYes
Ampere meterYes
Reactive power meterYes
With rotational speed meterNo
Frequency meterYes
Pulse counterNo
VoltmeterYes
Effective power measurement deviceYes
Accuracy class active energy according to IEC 62053-220.5S
Sampling frequency6400 Hz
Number of voltage measurement inputs4
Number of current measurement inputs6
Voltage type (supply voltage)AC/DC
DisplayLCD
Remote displayNo
Number of digital inputs2
Number of digital outputs4
Supporting protocol for IEC 61850 EthernetNo
Supporting protocol for OPC UA PubSubNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusYes
Supporting protocol for PROFINET IONo
Supporting protocol for other bus systemsYes
With audit logging (audit log)No
With firmware signatureNo
With logging of security events (security event log)Yes
With Role Based Access Control (RBAC)No
Web server with HTTPS transfer protocolNo

Properties

MOQ1

Cross-References

Attached Documents