Schneider Electric METSEPM5310 PM5310 Meter, modbus, up to 31ST H, 256K 2DI/2DO 35 alarms

Schneider Electric · Electrical Components · Energy Meters · France · se.com
Part Number
METSEPM5310  ·  HS 9028.30
Schneider Electric METSEPM5310 PM5310 Meter, modbus, up to 31ST H, 256K 2DI/2DO 35 alarms

Schneider Electric METSEPM5310 — PM5310 Meter, modbus, up to 31st H, 256K 2DI/2DO 35 alarms.

Technical Specifications

Manufacturer part number (MPN)METSEPM5310
EAN / GTIN3606480614002
Sales unitpcs
Package quantity12 pcs
RangePowerLogic
Product namePowerLogic PM5000
Product or component typePower meter
Device short namePM5310
Power quality analysisup to the 31st harmonic
Device applicationMulti-tariff; Power monitoring
Type of measurementCurrent; Voltage; Frequency; Power factor; Energy; Active and reactive power
[Us] rated supply voltage90...450 V AC 45...65 Hz; 100...300 V DC
Network frequency50 Hz; 60 Hz
[In] rated current1 A; 5 A
type of network1P + N; 3P; 3P + N
Maximum power consumption in VA11 VA at 415 V
Ride-through time80 ms 120 V AC typical; 100 ms 230 V AC typical; 100 ms 415 V AC typical; 50 ms 125 V DC typical
Display typeMonochrome graphic LCD
Display resolution128 x 128 pixels
Sampling rate64 samples/cycle
Measurement current5…8500 mA
Analogue input typeVoltage (impedance 5 MOhm); Current (impedance <= 0.3 mOhm)
Measurement voltage35…760 V AC 45...65 Hz between phases; 20…440 V AC 45...65 Hz between phase and neutral
Frequency measurement range45…65 Hz
Number of inputs2 digital
Measurement accuracyActive energy +/- 0.5 %; Reactive energy +/- 2 %; Active power +/- 0.5 %; Apparent power +/- 0.5 %; Frequency +/- 0.05 %; Power factor +/- 0.5; Current +/- 0.5 %; Voltage +/- 0.5 %; Apparent energy +/- 0.5 %; Reactive power +/- 2 %
Accuracy classClass 0.5S active energy conforming to IEC 62053-22
Number of outputs2 digital
Information displayedTariff (4)
Communication port protocolModbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V; JBUS
Communication port supportRS485
Data recordingEvent logs; Min/max of instantaneous values; Alarm logs; Data logs; Time stamping; Maintenance logs
Memory capacity256 kB
Connections - terminalsVoltage circuit: screw terminal block4; Control circuit: screw terminal block2; Current transformer: screw terminal block6; Input/output circuit: screw terminal block6; Relay output: screw terminal block4; Ethernet network: RJ45 connector
mounting modeFlush-mounted
Mounting supportFramework
StandardsEN 50470-3; IEC 62053-24; IEC 60529; EN 50470-1; UL 61010-1; IEC 62053-22:2020; IEC 61557-12:2015; IEC 62053-23:2020; IEC 62052-11:2020; IEC 62052-31:2015
Product certificationsCE conforming to IEC 61010-1; CULus conforming to UL 61010-1
Width96 mm
Depth72 mm
Height96 mm
Product weight430 g
Electromagnetic compatibilityConducted and radiated emissions class A conforming to EN 55011; Limits for harmonic current emissions class A conforming to IEC 61000-3-2; Immunity to conducted disturbances - test level: 150 kHz...80 MHz level 3 conforming to IEC 61000-4-6; Voltage dips and interruptions immunity test level 4 conforming to IEC 61000-4-11; Conducted RF disturbances level 3 conforming to IEC 61000-4-6; Magnetic field at power frequency level 4 conforming to IEC 61000-4-8; Conducted and radiated emissions class B conforming to EN 55022; Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3; Electrostatic discharge - test level: 8 kV level 4 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; Surge immunity test level 4 conforming to IEC 61000-4-5; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
IP degree of protectionIP54 display: conforming to IEC 60529; IP30 rear: conforming to IEC 60529
Relative humidity5…95 % at 50 °C non-condensing
Pollution degree2
Ambient air temperature for operation-25…70 °C meter; -20…70 °C display; -25…-20 °C (with reduced performance) display
Ambient air temperature for storage-40…85 °C
Operating altitude2000 m CAT III; 3000 m CAT II
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.000 cm
Package 1 Width12.600 cm
Package 1 Length12.600 cm
Package 1 Weight473.000 g
Unit Type of Package 2S03
Number of Units in Package 212
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.333 kg
Unit Type of Package 3P06
Number of Units in Package 396
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight62.012 kg
Country of originIN
Warranty (in months)18
Measured value memoryYes
Power factorYes
Suitable for RJ plugNo
Step angle (cos phi)Yes
Harmonics measurementYes
Pulse outputOptical
CalibratedNo
Max. current (Imax)20 A
Measurement type load profileYes
With communication interface KNXNo
With communication interface M-BusNo
With communication interface RS-485Yes
ModelMeasurement transformer
Mounting methodFront mounting
Nominal current (In)5 A
Pole typeThree conductor/four conductor
Apparent powerYes
Connectable conductor cross section solid-core0.82–3.31 mm²
Ampere meterYes
Reactive power meterYes
With rotational speed meterNo
Frequency meterYes
Pulse counterNo
VoltmeterYes
Effective power measurement deviceYes
Accuracy class active energy according to IEC 62053-220.5S
Sampling frequency6400 Hz
Number of voltage measurement inputs4
Number of current measurement inputs6
Voltage type (supply voltage)AC/DC
Supply voltage AC 50 Hz100–415 V
Supply voltage AC 60 Hz100–415 V
Supply voltage DC125–250 V
Measuring range for frequency47–63 Hz
DisplayLCD
Remote displayNo
Number of digital inputs2
Number of digital outputs2
Supporting protocol for IEC 61850 EthernetNo
Supporting protocol for OPC UA PubSubNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusYes
Supporting protocol for PROFINET IONo
Supporting protocol for other bus systemsYes
With audit logging (audit log)No
With firmware signatureNo
With logging of security events (security event log)Yes
With Role Based Access Control (RBAC)No
Web server with HTTPS transfer protocolNo