Schneider Electric standard analog input kit - Modicon STB - +/- 10 V - 2 I -11 bits + sign STBAVI1270K

Schneider Electric · Control & Automation · PLCs & Industrial Networking · France · se.com
Part Number
STBAVI1270K  ·  HS 8538.90
Schneider Electric standard analog input kit - Modicon STB - +/- 10 V - 2 I -11 bits + sign STBAVI1270K

Schneider Electric STBAVI1270K STB kit 2 in analog, +/-10V, 12bit.

Technical Specifications

Manufacturer part number (MPN)STBAVI1270K
EAN / GTIN3595863988918
Sales unitpcs
Range of productModicon STB distributed I/O solution
Product or component typeStandard analog input kit
Kit compositionSTBXBA1000 base; STBXTS1100, 6-terminal screw type connector; STBAVI1270 module; STBXTS2100, 6-terminal spring clamp connector
Product compatibilityMounting base STBXBA1000; Power distribution module STBPDT3100/3105
Analogue input number2
Type of filterSingle low pass input filter 25 Hz
Analogue output number0
Absolute maximum input50 V
Cold swappingYes
Fallback statusState 0 basic NIMs; User configurable standard NIMs
Data formatIEC 61131-2; EN 61131-2
Update time10 ms
Integral linearity+/- 0.2 %FS
Differential linearityMonotonic
Maximum supply current for sensors100 mA per input channels
Absolute accuracy error+/- 0.5 % of full scale 25 °C
Addressing requirement4 input words
SupplyPower distribution module
Analogue input typeVoltage +/- 10 V
Analogue input resolution11 bits + sign
Input impedance400 kOhm
Input protection typeProtected against short-circuit
Temperature drift+/-0.01 %/°C
Typical current consumption30 mA at 5 V DC for logic bus
Isolation between channels and bus1500 V for 1 minute
Hot swapping fallbackYes for standard NIMs
Local signalling1 LED green for module status (RDY); 1 LED red for module error (ERR)
Height18.4 mm
Width128.3 mm
Depth70 mm
Product weight0.115 kg
Overvoltage categoryII
IP degree of protectionIP20
MarkingCE
Product certificationsCSA; C-Tick; UL; ATEX Cat 3G; FM Class 1 Division 2
Ambient air temperature for operation-25…70 °C (without derating)
Ambient air temperature for storage-40…85 °C without derating
Relative humidity95 % at 60 °C without condensation
Operating altitude2000 m
Pollution degree2
Vibration resistance+/-0.35 mm (f = 10…58 Hz); 3 gn (f = 58…150 Hz) on 35 mm DIN rail; 5 gn (f = 58…150 Hz) on 35 mm DIN rail
Shock resistance30 gn for 11 ms conforming to IEC 88 reference 2-27
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2.500 cm
Package 1 Width8.000 cm
Package 1 Length13.000 cm
Package 1 Weight138.000 g
Unit Type of Package 2S02
Number of Units in Package 228
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight4.326 kg
Country of originID
Warranty (in months)18
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Supporting protocol for EtherCATNo
Voltage type (supply voltage)AC/DC
Input, currentYes
Input, voltageNo
Input, resistorNo
Input, resistance thermometerNo
Input, thermocoupleNo
Input signal, configurableYes
Resolution of the analogue inputs11 Bit
Output, currentNo
Output, voltageNo
Output signal configurableNo
Resolution of the analogue outputs11 Bit
Number of analogue inputs2
Analogue inputs configurableYes
Analogue outputs configurableNo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Radio standard GPRSNo
Radio standard GSMNo
Mobile communications standard 3G (UMTS)No
IO link masterNo
System accessoryYes
Degree of protection (IP)IP20
Type of electric connectionScrew connection
Fieldbus connection over separate bus coupler possibleYes
Suitable for rail mountingYes
Wall mounting/direct mountingNo
Front built-in possibleNo
Rack-assembly possibleYes
Suitable for safety functionsNo
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Explosion safety category for gasATEX gas-ex-protection, Cat. 3G

Properties

MOQ1

Cross-References