Schneider Electric standard digital output kit STB - 115 V AC - 2 O STBDAO5260K

Schneider Electric · Control & Automation · I/O Modules · France · se.com
Part Number
STBDAO5260K  ·  HS 8538.90
Schneider Electric standard digital output kit STB - 115 V AC - 2 O STBDAO5260K

Schneider Electric STBDAO5260K STB kit 2 out, 115VAC, insulated.

Technical Specifications

Manufacturer part number (MPN)STBDAO5260K EAN / GTIN: 3595863949001 Sales unit: pcs Voltage: 115 V AC Range of product: Modicon STB distributed I/O solution Product or component type: Standard digital output kit Kit composition: STBXBA2000 base; STBDAO5260 module; STBXTS1100, 5-terminal screw type connector; STBXTS2110, 5-terminal spring clamp connector Product compatibility: Power distribution module STBPDT2100/2105; I/O base STBXBA2000 Range compatibility: Logic/motion controller - Modicon M262; Modicon M580; Third party Device application: Industrial application Discrete output number: 2 Discrete output logic: Positive logic (source)/negative logic (sink) Discrete output voltage: 115 V AC for triac Output voltage: 19.2...30 V DC Absolute maximum voltage: 132 V Discrete output current: 1000 mA at 60 °C; 2000 mA at 30 °C Response time on output: 10 ms off to on; 10 ms on to off Maximum leakage current: 2 mA AC at state 0 Output protection type: Output surge protection external fuse 5 A Power supply type: Power distribution module Typical current consumption: 70 mA at 5 V DC Electrical connection: Screw terminal Isolation between channels: 1780 Vrms for 1 minute Isolation between channels and bus: 1780 Vrms for 1 minute Fallback status: State 0 basic NIMs; User configurable standard NIMs Surge current: 20 A 40 ms; 30 A 20 ms minimum load: 1 mA Reset: Manual or automatic reset COM fault Overvoltage category: II Local signalling: 1 LED (green) for module status (RDY); 1 LED per channel (green) for channel status (OUT1 to OUT2); 1 LED (red) for module error (ERR) Height: 18.4 mm Width: 128.3 mm Depth: 70 mm Product weight: 0.067 kg IP degree of protection: IP20 Marking: CE Product certifications: CSA; UL; FM Class 1 Division 2 Standards: IEC 61131-2 Ambient air temperature for operation: 0…60 °C (without derating) Ambient air temperature for storage: -40…85 °C without derating Relative humidity: 95 % at 60 °C without condensation Operating altitude: <= 2000 m Pollution degree: 2 Vibration resistance: 3 gn (f = 58…150 Hz) on 35 x 7.5 mm symmetrical DIN rail; 5 gn (f = 58…150 Hz) on 35 x 15 mm symmetrical DIN rail; +/-0.35 mm (f = 10…58 Hz) Shock resistance: 30 gn for 11 ms conforming to IEC 88 reference 2-27 Number of Units in Package 1: 1 Number of Units in Package 2: 28 Warranty (in months): 18 Certified for UL hazardous location division 1: No Certified for UL hazardous location division 2: No Certified for UL hazardous location group A (acetylene): No Certified for UL hazardous location group B (hydrogen): No Certified for UL hazardous location group C (ethylene): No Certified for UL hazardous location group D (propane): No Certified for UL hazardous location group E (metal dusts): No Certified for UL hazardous location class I: No Certified for UL hazardous location class II: No Certified for UL hazardous location class III: No Supporting protocol for EtherCAT: No Supply voltage AC 50 Hz: 115 V Supply voltage AC 60 Hz: 115 V Voltage type (supply voltage): AC/DC Number of digital outputs: 2 digital inputs configurable: No digital outputs configurable: No Input current at signal 1: 2.5 mA Permitted voltage at input: -3–30 V Type of voltage (input voltage): AC/DC Type of digital output: None Output current: 2 A Permitted voltage at output: 74–132 V Type of output voltage: AC/DC Short-circuit protection, outputs available: No With optical interface: No Supporting protocol for TCP/IP: Yes Supporting protocol for PROFIBUS: Yes Supporting protocol for CAN: Yes Supporting protocol for INTERBUS: Yes Supporting protocol for ASI: No Supporting protocol for KNX: No Supporting protocol for Modbus: Yes Supporting protocol for Data-Highway: No Supporting protocol for DeviceNet: Yes Supporting protocol for SUCONET: No Supporting protocol for LON: No Supporting protocol for PROFINET IO: No Supporting protocol for PROFINET CBA: No Supporting protocol for SERCOS: No Supporting protocol for Foundation Fieldbus: No Supporting protocol for EtherNet/IP: Yes Supporting protocol for AS-Interface Safety at Work: No Supporting protocol for DeviceNet Safety: No Supporting protocol for INTERBUS-Safety: No Supporting protocol for PROFIsafe: No Supporting protocol for SafetyBUS p: No Supporting protocol for other bus systems: No Radio standard Bluetooth: No Radio standard WLAN 802.11: No Radio standard GPRS: No Radio standard GSM: No Mobile communications standard 3G (UMTS): No IO link master: No System accessory: Yes Degree of protection (IP): IP20 Type of electric connection: Screw connection Time delay at signal change: 0.925–1.35 ms Fieldbus connection over separate bus coupler possible: Yes Suitable for rail mounting: No Wall mounting/direct mounting: No Front built-in possible: No Rack-assembly possible: No Suitable for safety functions: No SIL according to IEC 61508: None Performance level according to EN ISO 13849-1: None Appendant operation agent (Ex ia): No Explosion safety category for gas: None Explosion safety category for dust: None Country of origin: Indonesia

Properties

MOQ1

Cross-References

Attached Documents