| Manufacturer part number (MPN) | SR3XT141JD |
| EAN / GTIN | 3389119203951 |
| Sales unit | pcs |
| Package quantity | 30 pcs |
| Voltage | 12 V DC |
| Range of product | Zelio Logic |
| Product or component type | Discrete I/O extension module |
| Number or control scheme lines | 120 with ladder programming |
| Cycle time | 6…90 ms |
| Backup time | 10 years at 25 °C |
| Clock drift | 12 min/year at 0…55 °C |
| Checks | Program memory on each power up |
| [Us] rated supply voltage | 12 V DC |
| Supply voltage limits | 10.4…14.4 V |
| Reverse polarity protection | With |
| Discrete input number | 8 conforming to IEC 61131-2 Type 1 |
| Discrete input type | Resistive |
| Discrete input voltage | 12 V DC |
| Discrete input current | 4 mA |
| Counting frequency | 1 kHz for discrete input |
| Voltage state 1 guaranteed | >= 7 V for IB...IG used as discrete input circuit; >= 5.6 V for I1...IA and IH...IR discrete input circuit |
| Voltage state 0 guaranteed | <= 3 V for IB...IG used as discrete input circuit; <= 2.4 V for I1...IA and IH...IR discrete input circuit |
| Current state 1 guaranteed | >= 2 mA (I1...IA and IH...IR discrete input circuit); >= 0.5 mA (IB...IG used as discrete input circuit) |
| Current state 0 guaranteed | <= 0.2 mA (IB...IG used as discrete input circuit); <= 0.9 mA (I1...IA and IH...IR discrete input circuit) |
| Input compatibility | 3-wire proximity sensors PNP for discrete input |
| Input impedance | 14 kOhm for IB...IG used as discrete input circuit; 2.7 kOhm for I1...IA and IH...IR discrete input circuit |
| Number of outputs | 6 relay |
| Output voltage limits | 24...250 V AC (relay output); 5...30 V DC (relay output) |
| Contacts type and composition | NO for relay output |
| Output thermal current | 5 A for 2 outputs for relay output; 8 A for 4 outputs for relay output |
| Electrical durability | AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to IEC 60947-5-1; AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to IEC 60947-5-1; DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to IEC 60947-5-1; DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to IEC 60947-5-1 |
| Switching capacity in mA | >= 10 mA at 12 V (relay output) |
| Operating rate in Hz | 0.1 Hz (at Ie) for relay output; 10 Hz (no load) for relay output |
| Mechanical durability | 10000000 cycles for relay output |
| [Uimp] rated impulse withstand voltage | 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 |
| Response time | 10 ms (from state 0 to state 1) for relay output; 5 ms (from state 1 to state 0) for relay output |
| Connections - terminals | Screw terminals, 1 x 0.25...1 x 2.5 mm² (24 AWG...14 AWG) flexible with cable end; Screw terminals, 2 x 0.25...2 x 0.75 mm² (24 AWG...18 AWG) flexible with cable end; Screw terminals, 1 x 0.2...1 x 2.5 mm² (25 AWG...14 AWG) semi-solid; Screw terminals, 1 x 0.2...1 x 2.5 mm² (25 AWG...14 AWG) solid; Screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) solid |
| Tightening torque | 0.5 N.m |
| Overvoltage category | III conforming to IEC 60664-1 |
| Product weight | 0.22 kg |
| Product certifications | GL; UL; GOST; C-Tick; CSA |
| Standards | IEC 61000-4-6 level 3; IEC 61000-4-3; IEC 61000-4-2 level 3; IEC 61000-4-4 level 3; IEC 60068-2-27 Ea; IEC 61000-4-12; IEC 60068-2-6 Fc; IEC 61000-4-11; IEC 61000-4-5 |
| IP degree of protection | IP20 (terminal block) conforming to IEC 60529; IP40 (front panel) conforming to IEC 60529 |
| Environmental characteristic | EMC directive conforming to IEC 61000-6-2; EMC directive conforming to IEC 61000-6-3; EMC directive conforming to IEC 61000-6-4; EMC directive conforming to IEC 61131-2 zone B; Low voltage directive conforming to IEC 61131-2 |
| Disturbance radiated/conducted | Class B conforming to EN 55022-11 group 1 |
| Pollution degree | 2 conforming to IEC 61131-2 |
| Ambient air temperature for operation | -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2; -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2 |
| Ambient air temperature for storage | -40…70 °C |
| Operating altitude | 2000 m |
| Maximum altitude transport | 3048 m |
| Relative humidity | 95 % without condensation or dripping water |
| Number of Units in Package 1 | 1 |
| Number of Units in Package 2 | 30 |
| Country of origin | FR |
| Warranty (in months) | 18 |
| Power consumption | 1.1 W |
| Certified for UL hazardous location division 1 | No |
| Certified for UL hazardous location division 2 | No |
| Certified for UL hazardous location group A (acetylene) | No |
| Certified for UL hazardous location group B (hydrogen) | No |
| Certified for UL hazardous location group C (ethylene) | No |
| Certified for UL hazardous location group D (propane) | No |
| Certified for UL hazardous location group E (metal dusts) | No |
| Certified for UL hazardous location class I | No |
| Certified for UL hazardous location class II | No |
| Certified for UL hazardous location class III | No |
| Supporting protocol for EtherCAT | No |
| Supply voltage DC | 12 V |
| Voltage type (supply voltage) | AC/DC |
| Switching current | 8 A |
| Number of digital inputs | 8 |
| Number of digital outputs | 6 |
| With relay output | Yes |
| With optical interface | No |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for ASI | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | No |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for LON | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for other bus systems | No |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Mobile communications standard 3G (UMTS) | No |
| IO link master | No |
| Redundancy | No |
| With display | No |
| Degree of protection (IP) | IP20 |
| Basic device | Yes |
| Expandable | No |
| Expansion device | Yes |
| With time switch clock | No |
| Suitable for rail mounting | Yes |
| Wall mounting/direct mounting | Yes |
| Front built-in possible | Yes |
| Rack-assembly possible | No |
| Suitable for safety functions | No |
| SIL according to IEC 61508 | None |
| Performance level according to EN ISO 13849-1 | None |
| Appendant operation agent (Ex ia) | No |
| Explosion safety category for gas | None |
| Explosion safety category for dust | None |
| Width | 72 mm |
| Height | 90 mm |
| Depth | 59.5 mm |