cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Schneider Electric TM3AM6G Modicon TM3 4 Analog Inputs 2 Analog Outputs Spring 24VDC

Schneider Electric · Control & Automation · PLCs & Industrial Networking · France · se.com
Part Number
TM3AM6G  ·  HS 8536.90
Schneider Electric TM3AM6G Modicon TM3 4 Analog Inputs 2 Analog Outputs Spring 24VDC

Schneider Electric TM3AM6G accessories Modicon PLC - I/O expansion - 4 analog outputs, analog inputs, spring terminal.

Technical Specifications

Manufacturer part number (MPN)TM3AM6G
EAN / GTIN3606480648953
Sales unitpcs
Package quantity9 pcs
Range of productModicon TM3
Product or component typeInput/output analog module
Range compatibilityModicon M221; Modicon M241; Modicon M251; Modicon M262
Analogue input number4
Analogue output number2
Analogue input typeCurrent 4...20 mA; Current 0...20 mA; Voltage 0...10 V; Voltage - 10...10 V
Analogue input resolution12 bits; 11 bits + sign
Permissible continuous overload13 V, analogue input type: voltage; 40 mA, analogue input type: current
Stabilisation time1 ms
Input impedance= 1 MOhm
Sampling duration1 ms
Analogue output typeCurrent: 4...20 mA; Current: 0...20 mA; Voltage: 0...10 V; Voltage: - 10...10 V
Conversion time1 ms + 1 ms per channel + 1 controller cycle time
Absolute accuracy error+/- 1 % of full scale; +/- 0.2 % of full scale at 25 °C
Repeat accuracy+/-0.5 %FS for input
Output ripple20 mV
Cross talk<= 1 LSB
Type of cableTwisted shielded pairs cable <30 m for input/output circuit
Electrical connection10 x 1.5 mm² removable spring terminal block with pitch 3.81 mm adjustment for inputs; 10 x 1.5 mm² removable spring terminal block with pitch 3.81 mm adjustment for inputs, outputs and supply
LSB value2.44 mV, 0...10 V; 4.88 mV, - 10...10 V; 4.88 µA, 0...20 mA; 3.91 µA, 4...20 mA
InsulationBetween input and supply at 1500 V AC; Between input and internal logic at 500 V AC; Between output and supply at 1500 V AC; Between output and internal logic at 500 V AC
Immunity to microbreaks10 ms
Load impedance ohmic1 kOhm voltage; 300 Ohm current
load typeResistive
Temperature drift+/- 0.01 %FS/°C
Non-linearity+/- 0.2 %FS
Typical current consumption45 mA at 5 V DC no load; 55 mA at 5 V DC full load; 55 mA at 24 V DC no load; 100 mA at 24 V DC full load
Local signalling1 LED green for PWR
Mounting supportTop hat type TH35-15 rail conforming to IEC 60715; Top hat type TH35-7.5 rail conforming to IEC 60715; plate or panel with fixing kit
Height90 mm
Width23.6 mm
Depth70 mm
Product weight0.1 kg
IP degree of protectionIP20
MarkingCE
Product certificationsCE; UKCA; RCM; EAC; CULus; CULus HazLoc
StandardsIEC 61131-2
Electromagnetic emissionRadiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011; Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 230…1000 MHz conforming to IEC 55011
Ambient air temperature for operation-10…55 °C (horizontal installation); -10…35 °C (vertical installation)
Ambient air temperature for storage-25…70 °C
Relative humidity10…95 % without condensation
Operating altitude0...2000 m
Pollution degree2
Vibration resistance3.5 mm (f = 5…8.4 Hz) on DIN rail; 3 gn (f = 8.4…150 Hz) on DIN rail
Shock resistance15 gn for 11 ms
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.5 cm
Package 1 Width12.5 cm
Package 1 Length10.5 cm
Package 1 Weight195.0 g
Unit Type of Package 2S02
Number of Units in Package 29
Package 2 Height15 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight2.294 kg
Unit Type of Package 3P12
Number of Units in Package 3144
Package 3 Height75 cm
Package 3 Width120 cm
Package 3 Length80 cm
Package 3 Weight46 kg
Country of originJP
Warranty (in months)18
Power consumption1.1 W
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Supporting protocol for EtherCATNo
Supply voltage DC24 V
Voltage type (supply voltage)DC
Input, currentYes
Input, voltageYes
Input, resistorNo
Input, resistance thermometerNo
Input, thermocoupleNo
Input signal, configurableNo
Resolution of the analogue inputs12 Bit
Output, currentYes
Output, voltageYes
Output signal configurableNo
Resolution of the analogue outputs12 Bit
Number of analogue inputs2
Number of analogue outputs4
Analogue inputs configurableNo
Analogue outputs configurableNo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Radio standard GPRSNo
Radio standard GSMNo
Mobile communications standard 3G (UMTS)No
IO link masterNo
System accessoryNo
Degree of protection (IP)IP20
Type of electric connectionSpring clamp connection
Fieldbus connection over separate bus coupler possibleNo
Suitable for rail mountingYes
Wall mounting/direct mountingNo
Front built-in possibleNo
Rack-assembly possibleNo
Suitable for safety functionsNo
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Explosion safety category for gasNone
Explosion safety category for dustNone

Properties

MOQ1

Cross-References

Attached Documents