| Manufacturer part number (MPN) | TM3XFHSC202G |
| EAN / GTIN | 3606489604288 |
| Sales unit | pcs |
| Package quantity | 18 pcs |
| Range of product | Modicon TM3 |
| Product or component type | Module hight speed counting |
| [Us] rated supply voltage | 24 V DC by external supply (- 15...20 %) |
| Number of input channels | 10 |
| Number of output channels | 8 |
| Discrete I/O number | 18 |
| Range compatibility | Modicon M262 |
| Current consumption | 100 mA at 5 V DC; 50 mA at 24 V DC |
| Counting frequency | 200 kHz |
| Discrete input voltage | 24 V DC |
| Electrical circuit type | Standard input; Latch input |
| Discrete input logic | Sink or source |
| Output voltage | 24 V DC for transistor output |
| Output voltage limits | 30 V DC |
| Discrete output current | 300 mA for fast output (Q0...Q7) |
| Discrete output logic | Source |
| Output protection type | Against overload and short-circuits |
| Reset | Automatic reset |
| Local signalling | 1 LED for I/O; 1 LED for RUN; 1 LED for ERR |
| Mounting support | Top hat type TH35-15 rail conforming to IEC 60715; Top hat type TH35-7.5 rail conforming to IEC 60715; plate or panel with fixing kit |
| Services | HSC simple - functions available: One shot/Modulo; HSC main single phase - functions available: One shot/Modulo/Event counting; HSC main dual phase - functions available: Modulo/Free-large; Period meter - functions available: Edge to Edge, Edge to Opposite |
| Counting mode | 2 main expert function (main counting function, frequency meter, period meter); Max 8 simple counting function |
| Event management | 8 maximum per PLC <= 100 µs; Thresholds < 10 µs |
| Height | 90 mm |
| Depth | 85 mm |
| Width | 39 mm |
| Product weight | 150 g |
| DC supply voltage | 24 V |
| Product certifications | CSA; cULus; IACS E10; RCM; CE; UKCA; EAC |
| Standards | CSA C22.2 No 142; ANSI/ISA 12-12-01; UL 1604; CSA C22.2 No 213; EN/IEC 61131-2:2007; UL 508 |
| Resistance to electrostatic discharge | 8 kV in air conforming to EN/IEC 61000-4-2; 4 kV on contact conforming to EN/IEC 61000-4-2 |
| Resistance to electromagnetic fields | 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3; 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3; 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3 |
| Resistance to fast transients | 2 kV for alimentation cable conforming to EN/IEC 61000-4-4; 1 kV for Ethernet line conforming to EN/IEC 61000-4-4; 1 kV for serial link conforming to EN/IEC 61000-4-4; 1 kV for input conforming to EN/IEC 61000-4-4; 1 kV for transistor output conforming to EN/IEC 61000-4-4 |
| Resistance to conducted disturbances | 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-4 |
| Electromagnetic emission | Conducted emissions - test level: 120...69 dBµV/m QP at 10…150 kHz conforming to EN/IEC 55011; Conducted emissions - test level: 63 dBμV/m QP at 1.5…30 MHz conforming to EN/IEC 55011; Radiated emissions - test level: 40 dBµV/m class A at 30…230 MHz conforming to EN/IEC 55011; Conducted emissions - test level: 79...63 dBμV/m QP at 150…1500 kHz conforming to EN/IEC 55011; Radiated emissions - test level: 47 dBµV/m class A at 230…1000 MHz conforming to EN/IEC 55011 |
| Ambient air temperature for operation | -20…60 °C horizontal installation; -20…50 °C vertical installation |
| Ambient air temperature for storage | -40…85 °C |
| Relative humidity | 10…95 %, without condensation (in operation); 10…95 %, without condensation (in storage) |
| IP degree of protection | IP20 with protective cover in place |
| Pollution degree | 2 |
| Operating altitude | 0...2000 m |
| Storage altitude | 0…3000 m |
| Vibration resistance | 3.5 mm at 2…8.4 Hz on DIN rail; 1 gn at 8.4…200 Hz on DIN rail; 3.5 mm at 2…8.4 Hz on panel; 1 gn at 8.4…200 Hz on panel |
| Shock resistance | 15 gn for 11 ms |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.200 cm |
| Package 1 Width | 10.400 cm |
| Package 1 Length | 12.400 cm |
| Package 1 Weight | 209.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 18 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 4.658 kg |
| Country of origin | ID |
| Warranty (in months) | 18 |
| Certified for UL hazardous location division 1 | No |
| Certified for UL hazardous location division 2 | No |
| Certified for UL hazardous location group A (acetylene) | No |
| Certified for UL hazardous location group B (hydrogen) | No |
| Certified for UL hazardous location group C (ethylene) | No |
| Certified for UL hazardous location group D (propane) | No |
| Certified for UL hazardous location group E (metal dusts) | No |
| Certified for UL hazardous location class I | No |
| Certified for UL hazardous location class II | No |
| Certified for UL hazardous location class III | No |
| Supporting protocol for EtherCAT | No |
| Supply voltage DC | 24 V |
| Voltage type (supply voltage) | DC |
| Number of functions | 2 |
| With optical interface | No |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for ASI | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | No |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for LON | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for other bus systems | No |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Mobile communications standard 3G (UMTS) | No |
| IO link master | No |
| System accessory | No |
| Suitable for counting | Yes |
| Suitable for weighing | No |
| Suitable for temperature control | No |
| Suitable for welding control | No |
| Suitable for pressure control | No |
| Suitable for NC | No |
| Suitable for electronic positioning | Yes |
| Suitable for CNC | No |
| Suitable for SSI | No |
| Suitable for incremental data detection | No |
| Suitable for detection absolute value | No |
| Suitable for flux controller | No |
| Suitable for flux measurement | No |
| Suitable for path controller | No |
| Suitable for cam controller | No |
| Suitable for multi-axis control | No |
| Suitable for single-axis controller | No |
| Suitable for multi-axis positioning | No |
| Suitable for single-axis positioning | No |
| Function block restart blockage | No |
| Function block automatic reset | No |
| Contactor control function block | No |
| Function block emergency stop | No |
| Function block contactless working protection installation | No |
| Function block affirm push button | No |
| Function block 2-hand switching | No |
| Function block operating mode selection | No |
| Function block access control | No |
| Degree of protection (IP) | IP20 |
| Fieldbus connection over separate bus coupler possible | No |
| Frequency measurement | Yes |
| Suitable for rail mounting | Yes |
| Wall mounting/direct mounting | No |
| Front built-in possible | No |
| Rack-assembly possible | No |
| Suitable for safety functions | No |
| SIL according to IEC 61508 | None |
| Performance level according to EN ISO 13849-1 | None |
| Appendant operation agent (Ex ia) | No |
| Explosion safety category for gas | None |
| Explosion safety category for dust | None |