Schneider Electric Module hight speed counting, Modicon TM3, 2 channels HSC Event management, 10 inputs, 8 outputs (screw) TM3XFHSC202

Schneider Electric · Control & Automation · PLCs & Industrial Networking · France · se.com
Part Number
TM3XFHSC202  ·  HS 9029.10
Schneider Electric Module hight speed counting, Modicon TM3, 2 channels HSC Event management, 10 inputs, 8 outputs (screw) TM3XFHSC202

Schneider Electric TM3XFHSC202 Modicon extension module TM3 Expert 2 HSC + event screw terminal, bare for M262 PLS.

Technical Specifications

Manufacturer part number (MPN)TM3XFHSC202
EAN / GTIN3606489604264
Sales unitpcs
Package quantity18 pcs
Range of productModicon TM3
Product or component typeModule hight speed counting
[Us] rated supply voltage24 V DC by external supply (- 15...20 %)
Number of input channels10
Number of output channels8
Discrete I/O number18
Range compatibilityModicon M262
Current consumption100 mA at 5 V DC; 50 mA at 24 V DC
Counting frequency200 kHz
Discrete input voltage24 V DC
Electrical circuit typeStandard input; Latch input
Discrete input logicSink or source
Output voltage24 V DC for transistor output
Output voltage limits30 V DC
Discrete output current300 mA for fast output (Q0...Q7)
Discrete output logicSource
Output protection typeAgainst overload and short-circuits
ResetAutomatic reset
Local signalling1 LED for I/O; 1 LED for RUN; 1 LED for ERR
Mounting supportTop hat type TH35-15 rail conforming to IEC 60715; Top hat type TH35-7.5 rail conforming to IEC 60715; plate or panel with fixing kit
ServicesHSC simple - functions available: One shot/Modulo; HSC main single phase - functions available: One shot/Modulo/Event counting; HSC main dual phase - functions available: Modulo/Free-large; Period meter - functions available: Edge to Edge, Edge to Opposite
Counting mode2 main expert function (main counting function, frequency meter, period meter); Max 8 simple counting function
Event management8 maximum per PLC <= 100 µs; Thresholds < 10 µs
Height90 mm
Depth85 mm
Width39 mm
Product weight150 g
DC supply voltage24 V
Product certificationsCSA; cULus; IACS E10; RCM; CE; UKCA; EAC
StandardsCSA C22.2 No 142; ANSI/ISA 12-12-01; UL 1604; CSA C22.2 No 213; EN/IEC 61131-2:2007; UL 508
Resistance to electrostatic discharge8 kV in air conforming to EN/IEC 61000-4-2; 4 kV on contact conforming to EN/IEC 61000-4-2
Resistance to electromagnetic fields10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3; 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3; 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3
Resistance to fast transients2 kV for alimentation cable conforming to EN/IEC 61000-4-4; 1 kV for Ethernet line conforming to EN/IEC 61000-4-4; 1 kV for serial link conforming to EN/IEC 61000-4-4; 1 kV for input conforming to EN/IEC 61000-4-4; 1 kV for transistor output conforming to EN/IEC 61000-4-4
Resistance to conducted disturbances10 V 0.15...80 MHz conforming to EN/IEC 61000-4-4
Electromagnetic emissionConducted emissions - test level: 120...69 dBµV/m QP at 10…150 kHz conforming to EN/IEC 55011; Conducted emissions - test level: 63 dBμV/m QP at 1.5…30 MHz conforming to EN/IEC 55011; Radiated emissions - test level: 40 dBµV/m class A at 30…230 MHz conforming to EN/IEC 55011; Conducted emissions - test level: 79...63 dBμV/m QP at 150…1500 kHz conforming to EN/IEC 55011; Radiated emissions - test level: 47 dBµV/m class A at 230…1000 MHz conforming to EN/IEC 55011
Ambient air temperature for operation-20…60 °C horizontal installation; -20…50 °C vertical installation
Ambient air temperature for storage-40…85 °C
Relative humidity10…95 %, without condensation (in operation); 10…95 %, without condensation (in storage)
IP degree of protectionIP20 with protective cover in place
Pollution degree2
Operating altitude0...2000 m
Storage altitude0…3000 m
Vibration resistance3.5 mm at 2…8.4 Hz on DIN rail; 1 gn at 8.4…200 Hz on DIN rail; 3.5 mm at 2…8.4 Hz on panel; 1 gn at 8.4…200 Hz on panel
Shock resistance15 gn for 11 ms
Number of Units in Package 11
Number of Units in Package 218
Country of originID
Warranty (in months)18
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Supporting protocol for EtherCATNo
Supply voltage DC24 V
Voltage type (supply voltage)DC
Number of functions2
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Radio standard GPRSNo
Radio standard GSMNo
Mobile communications standard 3G (UMTS)No
IO link masterNo
System accessoryNo
Suitable for countingYes
Suitable for weighingNo
Suitable for temperature controlNo
Suitable for welding controlNo
Suitable for pressure controlNo
Suitable for NCNo
Suitable for electronic positioningYes
Suitable for CNCNo
Suitable for SSINo
Suitable for incremental data detectionNo
Suitable for detection absolute valueNo
Suitable for flux controllerNo
Suitable for flux measurementNo
Suitable for path controllerNo
Suitable for cam controllerNo
Suitable for multi-axis controlNo
Suitable for single-axis controllerNo
Suitable for multi-axis positioningNo
Suitable for single-axis positioningNo
Function block restart blockageNo
Function block automatic resetNo
Contactor control function blockNo
Function block emergency stopNo
Function block contactless working protection installationNo
Function block affirm push buttonNo
Function block 2-hand switchingNo
Function block operating mode selectionNo
Function block access controlNo
Degree of protection (IP)IP20
Fieldbus connection over separate bus coupler possibleNo
Frequency measurementYes
Suitable for rail mountingYes
Wall mounting/direct mountingNo
Front built-in possibleNo
Rack-assembly possibleNo
Suitable for safety functionsNo
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Explosion safety category for gasNone
Explosion safety category for dustNone

Properties