| Manufacturer part number (MPN) | XB4BG41GEX |
| EAN / GTIN | 3606489485771 |
| Sales unit | pcs |
| Range of product | Harmony XB4 |
| Product or component type | Complete selector switch |
| Device short name | XB4 |
| Bezel material | Chromium plated metal |
| Fixing collar material | Zamak |
| Mounting diameter | 22 mm |
| Sale per indivisible quantity | 1 |
| Dust zone | Zone 21 - 22 |
| Gas zone | Zone 1 - 2 |
| Type of operator | stay put |
| Operator profile | key switch |
| Key number | 455 |
| Contacts type and composition | 1 NO |
| Width | 46.2 mm |
| Height | 30 mm |
| Depth | 110 mm |
| Product weight | 0.158 kg |
| Device mounting | Fixing hole - diameter: 22.5 mm +/- 0.2 mm conforming to IEC 60947-1 |
| Fixing center | >= 30 x 40 mm (support panel) - thickness: 1…6 mm |
| Embedding depth | 58 mm |
| Marking | Ex tb IIIC Db; Ex db eb IIC Gb; II 2 GD |
| Shape of signaling unit head | Round |
| Operator position information | 2 positions 90° |
| Key withdrawal position | In any position |
| Contact operation | Slow-break |
| Contacts usage | Standard contacts |
| Positive opening | Without |
| Mechanical durability | 5000000 cycles |
| Connections - terminals | Screw clamp terminals, 2 x 1.5 mm² with cable end conforming to IEC 60947-1; Screw clamp terminals, 1 x 2.5 mm² without cable end conforming to IEC 60947-1 |
| Tightening torque | 0.8…1.2 N.m conforming to IEC 60947-1 |
| [Ith] conventional free air thermal current | 10 A conforming to IEC 60947-5-1 |
| [Ui] rated insulation voltage | 415 V |
| [Ie] rated operational current | 1.9 A at 380 V, AC, A600 conforming to IEC 60947-5-1; 3 A at 240 V, AC, A600 conforming to IEC 60947-5-1; 6 A at 120 V, AC, A600 conforming to IEC 60947-5-1; 0.27 A at 250 V, DC, Q300 conforming to IEC 60947-5-1; 0.55 A at 125 V, DC, Q300 conforming to IEC 60947-5-1; 2.87 A at 24 V, DC, Q300 conforming to IEC 60947-5-1 |
| Protective treatment | TH |
| Ambient air temperature for storage | -40…70 °C |
| Ambient air temperature for operation | -20…75 °C |
| IP degree of protection | IP66 conforming to IEC 60529 |
| Standards | IEC 60079-0:2009; EN/IEC 60079-1:2009; IEC 60079-7:2009; IEC 60079-31:2009; UL 60079-0; UL 60079-1; UL 60079-31; ANSI/ISA 12.12.01; CSA C22.2 No 213 |
| Product certifications | INERIS 04ATEX9004U |
| Number of Units in Package 1 | 1 |
| Number of Units in Package 2 | 40 |
| Warranty (in months) | 18 |
| Hole diameter | 22.5 mm |
| Colour button | Black |
| Number of switch positions | 2 |
| Suitable for lighting | No |
| Spring-return | No |
| Colour front ring | Black |
| Type of electric connection | Spring clamp connection |
| Degree of protection (IP) | IP66 |
| With light source | No |
| Material front ring | Metal |
| With front ring | Yes |
| Type of control element | Key |
| Switching function latching | Yes |
| Number of contacts as normally open contact | 1 |
| Country of origin | France |