Schneider Electric Circuit breaker, ComPacT NSX1200N DC, 50KA/600VDC, 2 poles, TM-DC trip unit 1200A, without bare cable connector C1BN2TM12HD

Schneider Electric · Electrical Components · Moulded Case Circuit Breakers · France · se.com
Part Number
C1BN2TM12HD  ·  HS 8536.90
Schneider Electric Circuit breaker, ComPacT NSX1200N DC, 50KA/600VDC, 2 poles, TM-DC trip unit 1200A, without bare cable connector C1BN2TM12HD

Schneider Electric C1BN2TM12HD Circuit breaker ComPacT NSX1200N-DC 2P with thermomagnetic protection-1200A TMD 50kA/600VDC.

Technical Specifications

Manufacturer part number (MPN)C1BN2TM12HD
EAN / GTIN3606482005655
HS code8536.90
Sales unitpcs
Number of poles2P
Breaking capacity50 kA
RangeComPacT
Product nameComPacT NSX DC
Device short nameNSX1200 DC
Product or component typeCircuit breaker
Device applicationDistribution
Poles description2P
Protected poles description2D
[In] rated current1200 A at 40 °C
[Ue] rated operational voltage600 V DC
Network typeDC
Suitability for isolationYes conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Breaking capacity codeN 50 kA 600 V DC
Trip unit nameTM-DC
Trip unit technologyThermal-magnetic
Trip unit protection functionsLI
Control typeToggle
Circuit breaker mounting modeFixed
[Ui] rated insulation voltage750 V DC conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947-2
[Ics] rated service breaking capacity12.5 kA at 24...300 V DC conforming to IEC 60947-2; 12.5 kA at 300...600 V DC conforming to IEC 60947-2
Mechanical durability5000 cycles
Electrical durability2000 cycles at 600 V In/2; 1000 cycles at 600 V In
Mounting supportBackplate
Mounting positionHorizontal and vertical; Flat on the back
Upside connectionFront
Downside connectionFront
Connection pitch45 mm
Protection typeL : for overload protection (thermal); I : for short-circuit protection (magnetic)
Trip unit rating1200 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Long-time protection delay adjustment type trFixed
Instantaneous protection pick-up adjustment type IiAdjustable
[Ii] instantaneous protection pick-up adjustment range2.5...5 x In
Earth-leakage protectionWithout
Number of slots6 slot(s)
Width (W)185 mm
Height (H)485 mm
Depth (D)110 mm
Product weight9.4 kg
StandardsEN/IEC 60947-2
Overvoltage categoryIII
Electrical shock protection classClass II on front face
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude0...2000 m without derating; 2000 m...5000 m with derating
Warranty (in months)18