Schneider Electric Trip unit MicroLogic Vigi 4.3AL, ComPacT NSX630, 4 poles, electronic basic protections, earth leakage alarm, 570A C6344A570

Schneider Electric · Electrical Components · Circuit Breaker Accessories · France · se.com
Part Number
C6344A570  ·  HS 8536.90
Schneider Electric Trip unit MicroLogic Vigi 4.3AL, ComPacT NSX630, 4 poles, electronic basic protections, earth leakage alarm, 570A C6344A570

Schneider Electric C6344A570 Protection for Circuit breaker ComPacT NSX630-electronic protection-Micrologic 4.3AL 570A 4p with Earth-fault alarm.

Technical Specifications

Manufacturer part number (MPN)C6344A570
EAN / GTIN3606481994301
HS code8536.90
Sales unitpcs
Package quantity2 pcs
Rated current570 A
Trip unitMicrologic 4.3
RangeComPacT
Range of productComPacT NSX400...630
Product or component typeTrip unit
Trip unit nameMicroLogic 4.3 ALUMINIUM
Trip unit technologyElectronic
Range compatibilityComPacT NSX630
Device applicationDistribution
Poles description4P
Protected poles description3D + N/2; 4D; 3D
Neutral positionLeft
Trip unit protection functionsLSoI
Protection typeL : for overload protection (long time); So : for short time short-circuit protection with fixed delay; I : for instantaneous short-circuit protection
Trip unit rating570 A at 40 °C
[Ue] rated operational voltage440 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Circuit breaker mounting modeFixed
Long-time pick-up adjustment type Ir (thermal protection)Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range250...570 A
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range11 s at 7.2 x Ir; 16 s at 6 x Ir; 400 s at 1.5 x Ir
Neutral protection settings0.5 x Ir (3D + N/2); 1 x Ir (4D); No protection (3D)
Thermal memory20 minutes before and after tripping
Short-time protection pick-up adjustment type IsdAdjustable
[Isd] Short-time protection pick-up adjustment range1.5...10 x Ir
Short-time protection delay adjustment type tsdFixed
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range6900 A
Earth-leakage protectionIntegrated
Earth-leakage protection classClass A
Earth-leakage protection sensitity adjustment type IΔnAdjustable
[IΔn] earth-leakage protection sensitivity adjustment range0.3 A; 0.5 A; 1 A; 3 A; 5 A; 10 A
Earth-leakage protection specific modeOFF using the IΔn rotary switch
Earth-leakage protection time delay adjustement type ΔtAdjustable
[Δt] Earth-leakage protection time delay adjustment range0 ms; 60 ms; 150 ms; 500 ms; 1 s
Zone selective interlocking ZSIWithout
Local signallingFlashing LED (green) for ready to operate; LED 105 % Ir (red) for overload; LED 90 % Ir (orange) for overload; Color indicator (yellow) for residual current
StandardsEN/IEC 60947-2
Electrical shock protection classClass II
Pollution degree3 conforming to IEC 60947-1
IP degree of protectionIP40 conforming to IEC 60529
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Warranty (in months)18