Schneider Electric Circuit breaker, ComPacT NSX100S AC/DC, 70KA/415VAC, 2 poles, TMD trip unit 80A C10S2TM080

Schneider Electric · Electrical Components · Moulded Case Circuit Breakers · France · se.com
Part Number
C10S2TM080  ·  HS 8536.90
Schneider Electric Circuit breaker, ComPacT NSX100S AC/DC, 70KA/415VAC, 2 poles, TMD trip unit 80A C10S2TM080

Schneider Electric C10S2TM080 Circuit breaker ComPacT NSX100S AC/DC, 70 kA/ 415 VAC, with thermomagnetic protection TMD 80 A, 2p.

Technical Specifications

Manufacturer part number (MPN)C10S2TM080
EAN / GTIN3606482034372
HS code8536.90
Sales unitpcs
Package quantity12 pcs
Rated current80 A
Number of poles2P
Breaking capacity70 kA
RangeComPacT
Product nameComPacT NSX
Device short nameNSX100S
Product or component typeCircuit breaker
Device applicationDistribution
Poles description2P
Protected poles description2D
[In] rated current80 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz; 500 V DC
Network typeAC; DC
Network frequency50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Breaking capacity codeS 70 kA 415 V AC
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit protection functionsLI
Control typeToggle
Circuit breaker mounting modeFixed
[Ui] rated insulation voltage750 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947-2
[Ics] rated service breaking capacity100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2; 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2; 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2; 35 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2; 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA at 250 V DC conforming to IEC 60947-2; 100 kA at 500 V DC conforming to IEC 60947-2
Mechanical durability20000 cycles
Electrical durability20000 cycles at 277 V In/2; 10000 cycles at 277 V In
Power dissipation per pole8.77 W
Mounting supportBackplate
Mounting positionHorizontal and vertical; Flat on the back
Upside connectionFront
Downside connectionFront
Connection pitch35 mm
Protection typeL : for overload protection (thermal); I : for short-circuit protection (magnetic)
Trip unit rating80 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Fixed
[Ir] long-time protection pick-up adjustment range1 x In
Long-time protection delay adjustment type trFixed
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range640 A
Earth-leakage protectionWithout
Width (W)70 mm
Height (H)161 mm
Depth (D)86 mm
Product weight1.2 kg
StandardsEN/IEC 60947-2
Overvoltage categoryIII
Electrical shock protection classClass II on front face
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude0...2000 m without derating; 2000 m...5000 m with derating
Warranty (in months)18