| Manufacturer part number (MPN) | LV848499 |
| EAN / GTIN | 3606480811326 |
| HS code | 8536.90 |
| Sales unit | pcs |
| Range | MasterPacT |
| Device short name | MicroLogic 5.0 X |
| Product or component type | Control unit |
| Device application | Equipment protection, monitoring and control |
| Circuit breaker application | Distribution IEC standard |
| Range compatibility | MasterPact MTZ2 circuit breaker; MasterPact MTZ3 circuit breaker |
| Poles | 3P; 4P |
| Protected poles description | 3P 3d; 4P 3d; 4P 3d + N/2; 4P 4d; 4P 3d + OSN |
| [Ue] rated operational voltage | 690 V AC, +/- 10 % |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Trip unit technology | Electronic |
| Trip unit protection functions | LSI |
| Protection type | Overload protection (long time) conforming to ANSI 49; Instantaneous short-circuit protection conforming to ANSI 50; Short time short-circuit protection conforming to ANSI 51 |
| Trip unit rating | 400 A; 630 A; 800 A; 1000 A; 1250 A; 1600 A; 2000 A; 2500 A; 3200 A; 4000 A; 5000 A; 6300 A |
| mounting mode | Drawout |
| Neutral protection setting | 1 x Ir (4P 4d); 0.5 x Ir (4P 3d + N/2); 1.6 x Ir (4P 3d + OSN); No protection (4P 3d) |
| [Ir] long time pick-up adjustment range | 0.4...1 x In adjustable in step of 1 A |
| Long time delay adjustment type | Adjustable in step of 0.5 s |
| [tr] long-time delay adjustment range | 12.5…600 s at 1.5 x Ir; 0.5…24 s at 6 x Ir; 0.7…16.6 s at 7.2 x Ir |
| Thermal memory | Yes |
| [Isd] short-time pick-up adjustment range | 1.5...10 x Ir adjustable in step of 0.5 x Ir with embedded HMI; 1.5...10 x Ir adjustable in step of 0.1 x Ir with Ecoreach software or MasterPact MTZ mobile app |
| Short-time delay adjustment type | Adjustable |
| [tsd] short-time delay adjustment range | 0.1…0.4 s I²t=on; 0…0.4 s I²t=off |
| Instantaneous pick-up adjustment type Ii | Adjustable |
| [Ii] instantaneous pick-up adjustment range | 2...15 x In adjustable in step of 0.5 x In with embedded HMI; 2...15 x In adjustable in step of 0.1 x In with Ecoreach software or MasterPact MTZ mobile app; Ii enable on/off |
| [li mode] instantaneous delay adjustment range | 0 ms in fast; 20 ms in standard |
| Zone selective interlocking ZSI | With |
| Network and machine diagnosis type | System (HMI) health state overview: circuit breaker health state; Contacts state: circuit breaker health state; MicroLogic service life: circuit breaker health state; Tripping cause indication: circuit breaker tripping cause; Identification card: diagnostic data; Configured alarms synthesis: diagnostic data; Monitored function: diagnostic data; Operation: diagnostic data; MicroLogic test: test; Protection test: test; Selectivity test: test; Trip context information: crisis management; Operation: advanced diagnostic; Breaker service life: circuit breaker health state |
| Type of measurement | Power meter |
| Energy management | Measurement ,active, reactive and apparent energy; Measurement ,electrical network; Measurement ,energy |
| Metering type | Current I1, I2, I3, Iavg RMS; Neutral current IN RMS; Ground fault current Ig RMS; Voltage V12, V23, V31, VLLavg RMS; Voltage V1N, V2N, V3N, VLNavg RMS; Active power P, P1, P2, P3 total; Reactive power Q, Q1, Q2, Q3 total; Apparent power S, S1, S2, S3 total; Power factor; Active energy Ep IN/OUT/tot; Reactive energy Eq IN/OUT/tot; Apparent energy Es IN/OUT/tot; Demand current I1, I2, I3, In, Iavg; Demand power P, Q, S; Frequency; Phase sequence; Earth leakage current; Total current harmonic distortion THD (I); Total voltage harmonic distortion THD (V); Unbalance current; Unbalance voltage |
| Measurement voltage | 208…828 V AC 50/60 Hz phase to phase; 120…480 V AC 50/60 Hz phase to neutral |
| Frequency measurement range | 40…70 Hz |
| Measurement accuracy | Current I1, I2, I3, Iavg |
| Idemand for MTZ1 | +/- 0.5 % 40...1600 x 1.2 A; Current I1, I2, I3, Iavg |
| Idemand for MTZ2 | +/- 0.5 % 40...4000 x 1.2 A; Current I1, I2, I3, Iavg |
| Idemand for MTZ3 | +/- 0.5 % 80...6300 x 1.2 A; Neutral current IN: +/- 1 %; Ground fault current Ig: +/- 5 %; Voltage V12, V23, V31 |
| VLLavg | +/- 0.5 % 208...690 x 1.2 V; Voltage V1N, V2N, V3N |
| VLNavg | +/- 0.5 % 120...400 x 1.2 V; Active power P, P1, P2, P3 |
| Pdemand | +/- 1 %; Reactive power Q, Q1, Q2, Q3 |
| Qdemand | +/- 2 %; Apparent power S, S1, S2, S3 |
| Sdemand | +/- 1 %; Power factor: +/- 2 %; Active energy Ep IN/OUT/tot: +/- 1 %; Reactive energy Ep IN/OUT/tot: +/- 2 %; Apparent energy Es IN/OUT/tot: +/- 1 %; Frequency: +/- 0.005 Hz; Earth leakage current: +/- 10 %; Unbalance current: +/- 0.5 % |
| Accuracy class | Class 5: total current harmonic distortion THD (I); Class 0.5: unbalance voltage; Class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h); Class 2: total voltage harmonic distortion THD (V) |
| Display type | LCD display - 128 x 96 pixels |
| Communication port protocol | Bluetooth 4.0 LE peer to peer 30 kbit/s; NFC peer to peer conforming to ISO 15963; USB peer to peer 115 kbauds |
| Data recording | Event logs; Data logs; Time stamping; Alarm logs; Min/max of instantaneous values; Maintenance logs |
| Standards | EN/IEC 60947-2; EN/IEC 60947-1; EN/IEC 60255-1; EN/IEC 60092-202; EN/IEC 61010-1 |
| Mounting location | Indoor use only |
| Environmental characteristic | Wet location not approved for use conforming to IEC 61010-1 |
| Electromagnetic compatibility | Electrostatic discharge immunity test conforming to IEC 61000-4-2; Susceptibility to electromagnetic fields conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test conforming to IEC 61000-4-4; 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5; Conducted RF disturbances conforming to IEC 61000-4-6; Conducted and radiated emissions A conforming to CISPR 22 |
| Overvoltage category | IV conforming to IEC 61010-1 |
| Measurement category | Category IV conforming to IEC 61010-2-30 |
| Pollution degree | 3 conforming to IEC 60947-1 |
| Ambient air temperature for operation | -25…70 °C (operating); -35 °C (for start-up of product) |
| Relative humidity | 95 % at 55 °C conforming to IEC 60068-2-30 |
| Operating altitude | <= 2000 m without derating; <= 4000 m with operational voltage derating 600 V AC; <= 5000 m with operational voltage derating 560 V AC |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.7 cm |
| Package 1 Width | 7.9 cm |
| Package 1 Length | 21.6 cm |
| Package 1 Weight | 369.0 g |
| Country of origin | FR |
| Warranty (in months) | 18 |