Micrologic 2.0X protection fast MTZ (LV847280)

Schneider Electric · Electrical Components · Circuit Breaker Accessories · France · se.com
Part Number
LV847280  ·  HS 8536.90
Micrologic 2.0X protection fast MTZ (LV847280)

Schneider Electric LV847280 Micrologic 2.0X protection for fixed-mounted Masterpact MTZ circuit breaker.

Technical Specifications

Manufacturer part number (MPN)LV847280
EAN / GTIN3606480811227
HS code8536.90
Sales unitpcs
Trip unitMicrologic 2.0X
RangeMasterPacT
Device short nameMicroLogic 2.0 X
Product or component typeControl unit
Device applicationEquipment protection, monitoring and control
Circuit breaker applicationDistribution IEC standard
Range compatibilityMasterPact MTZ1 circuit breaker; MasterPact MTZ2 circuit breaker; MasterPact MTZ3 circuit breaker
Poles3P; 4P
Protected poles description3P 3d; 4P 3d; 4P 3d + N/2; 4P 4d; 4P 3d + OSN
[Ue] rated operational voltage690 V AC, +/- 10 %
Network typeAC
Network frequency50/60 Hz
Trip unit technologyElectronic
Trip unit protection functionsLI
Protection typeOverload protection (long time) conforming to ANSI 49; Instantaneous short-circuit protection conforming to ANSI 50
Trip unit rating400 A; 630 A; 800 A; 1000 A; 1250 A; 1600 A; 2000 A; 2500 A; 3200 A; 4000 A; 5000 A; 6300 A
mounting modeFixed
Neutral protection setting1 x Ir (4P 4d); 0.5 x Ir (4P 3d + N/2); 1.6 x Ir (4P 3d + OSN); No protection (4P 3d)
[Ir] long time pick-up adjustment range0.4...1 x In adjustable in step of 1 A
Long time delay adjustment typeAdjustable in step of 0.5 s
[tr] long-time delay adjustment range12.5…600 s at 1.5 x Ir; 0.5…24 s at 6 x Ir; 0.7…16.6 s at 7.2 x Ir
Thermal memoryYes
Instantaneous pick-up adjustment type IiAdjustable
[Ii] instantaneous pick-up adjustment range1.5...10 x Ir adjustable in step of 0.5 x Ir with embedded HMI; 1.5...10 x Ir adjustable in step of 0.1 x Ir with Ecoreach software or MasterPact MTZ mobile app
[li mode] instantaneous delay adjustment range20 ms in standard
Zone selective interlocking ZSIWithout
Network and machine diagnosis typeSystem (HMI) health state overview: circuit breaker health state; Contacts state: circuit breaker health state; MicroLogic service life: circuit breaker health state; Tripping cause indication: circuit breaker tripping cause; Identification card: diagnostic data; Configured alarms synthesis: diagnostic data; Monitored function: diagnostic data; Operation: diagnostic data; MicroLogic test: test; Protection test: test; Selectivity test: test; Trip context information: crisis management; Operation: advanced diagnostic; Breaker service life: circuit breaker health state
Type of measurementPower meter
Energy managementMeasurement ,active, reactive and apparent energy; Measurement ,electrical network; Measurement ,energy
Metering typeCurrent I1, I2, I3, Iavg RMS; Neutral current IN RMS; Ground fault current Ig RMS; Voltage V12, V23, V31, VLLavg RMS; Voltage V1N, V2N, V3N, VLNavg RMS; Active power P, P1, P2, P3 total; Reactive power Q, Q1, Q2, Q3 total; Apparent power S, S1, S2, S3 total; Power factor; Active energy Ep IN/OUT/tot; Reactive energy Eq IN/OUT/tot; Apparent energy Es IN/OUT/tot; Demand current I1, I2, I3, In, Iavg; Demand power P, Q, S; Frequency; Phase sequence; Earth leakage current; Total current harmonic distortion THD (I); Total voltage harmonic distortion THD (V); Unbalance current; Unbalance voltage
Measurement voltage208…828 V AC 50/60 Hz phase to phase; 120…480 V AC 50/60 Hz phase to neutral
Frequency measurement range40…70 Hz
Measurement accuracyCurrent I1, I2, I3, Iavg
Idemand for MTZ1+/- 0.5 % 40...1600 x 1.2 A; Current I1, I2, I3, Iavg
Idemand for MTZ2+/- 0.5 % 40...4000 x 1.2 A; Current I1, I2, I3, Iavg
Idemand for MTZ3+/- 0.5 % 80...6300 x 1.2 A; Neutral current IN: +/- 1 %; Ground fault current Ig: +/- 5 %; Voltage V12, V23, V31
VLLavg+/- 0.5 % 208...690 x 1.2 V; Voltage V1N, V2N, V3N
VLNavg+/- 0.5 % 120...400 x 1.2 V; Active power P, P1, P2, P3
Pdemand+/- 1 %; Reactive power Q, Q1, Q2, Q3
Qdemand+/- 2 %; Apparent power S, S1, S2, S3
Sdemand+/- 1 %; Power factor: +/- 2 %; Active energy Ep IN/OUT/tot: +/- 1 %; Reactive energy Ep IN/OUT/tot: +/- 2 %; Apparent energy Es IN/OUT/tot: +/- 1 %; Frequency: +/- 0.005 Hz; Earth leakage current: +/- 10 %; Unbalance current: +/- 0.5 %
Accuracy classClass 5: total current harmonic distortion THD (I); Class 0.5: unbalance voltage; Class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h); Class 2: total voltage harmonic distortion THD (V)
Display typeLCD display - 128 x 96 pixels
Communication port protocolBluetooth 4.0 LE peer to peer 30 kbit/s; NFC peer to peer 28800 bauds conforming to ISO 15963; USB peer to peer 115 kbauds
Data recordingAlarm logs; Data logs; Min/max of instantaneous values; Event logs; Time stamping; Maintenance logs
StandardsEN/IEC 60255-1; EN/IEC 60947-2; EN/IEC 60092-202; EN/IEC 60947-1; EN/IEC 61010-1
Mounting locationIndoor use only
Environmental characteristicWet location not approved for use conforming to IEC 61010-1
Electromagnetic compatibilityElectrostatic discharge immunity test conforming to IEC 61000-4-2; Susceptibility to electromagnetic fields conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test conforming to IEC 61000-4-4; 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5; Conducted RF disturbances conforming to IEC 61000-4-6; Conducted and radiated emissions A conforming to CISPR 22
Overvoltage categoryIV conforming to IEC 61010-1
Measurement categoryCategory IV conforming to IEC 61010-2-30
Pollution degree3 conforming to IEC 60947-1
Ambient air temperature for operation-25…70 °C (operating); -35 °C (for start-up of product)
Relative humidity95 % at 55 °C conforming to IEC 60068-2-30
Operating altitude<= 2000 m without derating; <= 4000 m with operational voltage derating 600 V AC; <= 5000 m with operational voltage derating 560 V AC
Number of Units in Package 11
Country of originFR
Warranty (in months)18

Properties

MOQ1

Cross-References