| Manufacturer part number (MPN) | C6AFM |
| EAN / GTIN | 3606482098275 |
| HS code | 8536.90 |
| Sales unit | pcs |
| Rated current | 6.0 A |
| Range | ComPacT |
| Range of product | ComPacT NS630b...1600 new generation; ComPacT NS1600b...3200 new generation |
| Product or component type | Control unit |
| Trip unit name | MicroLogic 6.0 A |
| Trip unit technology | Electronic |
| Range compatibility | ComPacT NS630b...1600; ComPacT NS1600b...3200 |
| Device application | Distribution |
| Number of poles | 3P; 4P |
| Protected poles description | 4t; 3t; 3t + N/2 |
| Trip unit protection functions | Selective + earth-fault protection |
| Protection type | L : for overload protection (long time); S : for short time short-circuit protection; I : for instantaneous short-circuit protection; G : for earth fault |
| Trip unit rating | 630 A at 50 °C; 800 A at 50 °C; 1000 A at 50 °C; 1250 A at 50 °C; 1600 A at 50 °C; 2000 A at 50 °C; 2500 A at 50 °C; 3200 A at 50 °C |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Circuit breaker mounting mode | Fixed |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
| [Ir] long-time protection pick-up adjustment range | 0.4...1 x In |
| Long-time protection delay adjustment type tr | Adjustable 9 settings |
| [tr] long-time protection delay adjustment range | 0.7…16.6 s at 7.2 x Ir; 0.7…24 s at 6 x Ir; 12.5…600 s at 1.5 x Ir |
| Thermal memory | 20 mn |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
| Short-time protection delay adjustment type tsd | Adjustable |
| [tsd] Short-time protection delay adjustment range | 0…0.4 s I²t=off; 0.1…0.4 s I²t=on |
| Instantaneous protection pick-up adjustment type Ii | Adjustable 9 settings |
| [Ii] instantaneous protection pick-up adjustment range | 2...15 x In; Off |
| Ground-fault protection pick-up adjustment type Ig | Adjustable 9 settings |
| [Ig] ground-fault protection pick-up adjustment range | 0.2...1 x In for 400 A = 1250 A |
| Ground-fault protection time delay adjustment type tg | Adjustable |
| [tg] ground-fault protection time delay adjustment range | 0…0.4 s I²t=off; 0.1…0.4 s I²t=on |
| Earth-leakage protection | Without |
| Zone selective interlocking ZSI | With |
| Local signalling | 3 LEDs (red) for electrical fault; 1 LED (red) for internal error; 1 LED (yellow) for overload |
| Display type | Digital display |
| Type of measurement | Ammeter |
| Communication of data | Measurement readout; Protection and alarm settings |
| Standards | IEC 60947-4-2 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -25…85 °C |
| Warranty (in months) | 18 |