Schneider Electric Illuminated emergency stop, Harmony XB5, plastic, 22mm, trigger latching turn to release, white red LED, 24V AC DC, 1 NO + 2 NC XB5AS84W3B41

Schneider Electric · Control & Automation · Pushbuttons & Pilot Lights · France · se.com
Part Number
XB5AS84W3B41  ·  HS 8536.50
Schneider Electric Illuminated emergency stop, Harmony XB5, plastic, 22mm, trigger latching turn to release, white red LED, 24V AC DC, 1 NO + 2 NC XB5AS84W3B41

Schneider Electric XB5AS84W3B41 — Harmony XB4 22 mm command actuator. Metal or plastic 22 mm cutout push-button, selector or indicator. Emergency stop square with push/turn and LED with red and white colour NO+2NC 24V.

Technical Specifications

Manufacturer part number (MPN)XB5AS84W3B41
EAN / GTIN3606489745622
Sales unitpcs
Package quantity40 pcs
Voltage24 V
Contact configurationNO + 2 NC
Range of productHarmony XB5
Product or component typeEmergency stop push-button; Emergency switching off push-button
Device short nameXB5
Bezel materialPlastic
Fixing collar materialPlastic
Head typeStandard
Mounting diameter22 mm
Sale per indivisible quantity1
Local signallingRed LED / white LED 24 V AC/DC
Light sourceProtected LED
Supply voltage24 V
Light source colourWhite; Red
Shape of signaling unit headRound
Type of operatortrigger action and mechanical latching
ResetTurn to release
Operator profileRed square 32 mm, IEC
Contacts type and composition1 NO + 2 NC
Contact operationSlow-break
Connections - terminalsScrew-clamp terminals, = 1 x 0.22 mm² with or without cable end conforming to IEC 60947-1
Device presentationComplete product
[Us] rated supply voltage24 V AC/DC at 50/60 Hz
Height60 mm
Width60 mm
Depth85 mm
Terminals description ISO n°1(1-2)NC; (3-4)NO
Product weight0.117 kg
Electrical insulation classClass II conforming to IEC 61140
Resistance to high pressure washer7000000 Pa at 55 °C, distance : 0.1 m
Device mountingFixing hole - diameter: 22.5 mm +/- 0.2 mm; Fixing hole - diameter: 9 mm +/- 0.5 mm
Fixing modeFixing nut (+/- 0.2)
Contacts usageStandard
Positive openingWith NC contact conforming to IEC 60947-5-1 appendix K
Operating travel1.5 mm (NC changing electrical state); 4.3 mm (total travel)
Mechanical durability300000 cycles
Tightening torque0.8…1.2 N.m conforming to IEC 60947-1
Shape of screw headCross compatible with Philips no 1 screwdriver; Cross compatible with pozidriv No 1 screwdriver; Slotted compatible with flat Ø 4 mm screwdriver; Slotted compatible with flat Ø 5.5 mm screwdriver
Contacts materialSilver alloy (Ag/Ni)
Short-circuit protection10 A cartridge fuse type gG conforming to IEC 60947-5-1
[Ith] conventional free air thermal current10 A conforming to IEC 60947-5-1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to IEC 60947-1
Resistance to electrostatic discharge4 kV on contact (on metal parts) conforming to IEC 61000-4-2; 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1; 6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1; 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1; 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1; 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1; 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1
Electrical durability1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Electrical reliabilityΛ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to IEC 60947-5-4; Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to IEC 60947-5-4
Protective treatmentTH
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-40…70 °C
IP degree of protectionIP66 conforming to IEC 60529; IP67 conforming to IEC 60529; IP69 conforming to IEC 60529; IP69K conforming to ISO 20653; Type 13 conforming to UL 50E; Type 12 conforming to UL 50E; Type 4 conforming to UL 50E; Type 4X conforming to UL 50E
IK degree of protectionIK05 conforming to IEC 50102
StandardsIEC 60947-5-1; IEC 60947-5-4; UL 508; ISO 21702; ISO 22196:2011
Product certificationsUL listed; CSA; EAC; CCC
Vibration resistance5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6; 25 mm peak to peak (f= 2…10 Hz) conforming to IEC 60068-2-6
Shock resistance30 gn (duration = 18 ms) for half its wave acceleration conforming to IEC 60068-2-27; 50 gn (duration = 11 ms) for half its wave acceleration conforming to IEC 60068-2-27; 25 gn (duration = 6 ms) for 1000 shocks on each axis conforming to IEC 60068-2-27
Warranty (in months)18
Unlocking methodTurn-release
Number of contacts as normally closed contact1
Number of contacts as normally open contact2
Degree of protection (IP)IP66
Mounting methodBuilt-in
With lightingYes
Supply voltage lamp24 V
Hole diameter22.5 mm
Connection type auxiliary circuitScrew connection
Diameter cap22 mm
Country of originCzechia

Properties

MOQ1

Cross-References