Schneider Electric Illuminated selector switch, Harmony XB4, metal, red handle, 30mm, universal LED, 3 positions, 1NO + 1NC, 230...240V AC XB4FK134M5

Schneider Electric · Control & Automation · Pushbuttons & Pilot Lights · France · se.com
Part Number
XB4FK134M5  ·  HS 8536.50
Schneider Electric Illuminated selector switch, Harmony XB4, metal, red handle, 30mm, universal LED, 3 positions, 1NO + 1NC, 230...240V AC XB4FK134M5

Schneider Electric XB4FK134M5 — Harmony XB4 22 mm command actuator. Metal or plastic 22 mm cutout push-button, selector or indicator. Selector switch flush with 3 fixed positionsitions and LED in orange colour 1xNO+1xNC 24VAC/DC.

Technical Specifications

Manufacturer part number (MPN)XB4FK134M5
EAN / GTIN3606489580421
Sales unitpcs
Voltage24 V
Range of productHarmony XB4
Product or component typeIlluminated selector switch
Device short nameXB4F
Bezel materialChromium plated metal
Fixing collar materialZamak
Head typeBuilt-in-flush
Mounting diameter30.5 mm
Sale per indivisible quantity1
Shape of signaling unit headRound
Type of operatorstay put
Operator profileRed standard handle
Operator position information3 positions +/- 45°
Contacts type and composition1 NO + 1 NC
Contact operationSlow-break
Connections - terminalsScrew clamp terminals, = 1 x 0.22 mm² without cable end conforming to IEC 60947-1
Light sourceUniversal LED
Bulb baseIntegral LED
[Us] rated supply voltage230...240 V AC at 50/60 Hz
Height53 mm
Width36.6 mm
Depth69.5 mm
Terminals description ISO n°1(13-14)NO; (21-22)NC
Product weight0.151 kg
Resistance to high pressure washer7000000 Pa at 55 °C, distance : 0.1 m
Device mountingBuilt-in - diameter: 30.75 mm +/- 0.25 mm
Fixing modeBy screws recommended torque: 0.8 N.m (0.8...1.2 Nm)
Contacts usageStandard contacts
Positive openingWith NC contact conforming to IEC 60947-5-1 appendix K
Operating torque0.14 N.m NO changing electrical state
Mechanical durability500000 cycles
Tightening torque0.8…1.2 N.m conforming to IEC 60947-1
Shape of screw headCross compatible with Philips no 1 screwdriver; Cross compatible with pozidriv No 1 screwdriver; Slotted compatible with flat Ø 4 mm screwdriver; Slotted compatible with flat Ø 5.5 mm screwdriver
Contacts materialSilver alloy (Ag/Ni)
Short-circuit protection10 A cartridge fuse type gG conforming to IEC 60947-5-1
[Ith] conventional free air thermal current10 A conforming to IEC 60947-5-1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1; 6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1; 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1; 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1; 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1; 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1
Electrical durability1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C; 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C; 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C; 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C; 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C
Electrical reliabilityΛ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to IEC 60947-5-4; Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to IEC 60947-5-4
Signalling typeSteady
Supply voltage limits195…264 V AC
Current consumption14 mA
Service life100000 h at rated voltage and 25 °C
Surge withstand1 kV conforming to IEC 61000-4-5
Device presentationComplete product
Protective treatmentTH
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-40…70 °C
Electrical shock protection classClass I conforming to IEC 60536
IP degree of protectionIP66 conforming to IEC 60529; IP67 conforming to IEC 60529; IP69 conforming to IEC 60529; IP69K conforming to ISO 20653; Type 13 conforming to UL 50 E; Type 12 conforming to UL 50 E; Type 4 conforming to UL 50 E; Type 4X conforming to UL 50 E
IK degree of protectionIK04 conforming to IEC 50102
StandardsCSA C22.2 No 14; IEC 60947-5-1; IEC 60947-5-4; UL 508; IEC 60947-1; JIS C8201-5-1; CE; JIS C8201-1
Product certificationsUL listed; CSA; CCC; EAC
Vibration resistance5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6; 2 mm peak to peak (f= 2…10 Hz) conforming to IEC 60068-2-6
Shock resistance30 gn (duration = 18 ms) for half its wave acceleration conforming to IEC 60068-2-27; 50 gn (duration = 11 ms) for half its wave acceleration conforming to IEC 60068-2-27; 25 gn (duration = 6 ms) for 1000 shocks on each axis conforming to IEC 60068-2-27
Resistance to fast transients2 kV conforming to IEC 61000-4-4
Resistance to electromagnetic fields10 V/m conforming to IEC 61000-4-3
Resistance to electrostatic discharge6 kV on contact (on metal parts) conforming to IEC 61000-4-2; 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2
Electromagnetic emissionClass B conforming to IEC 55011
Number of Units in Package 11
Warranty (in months)18

Properties

MOQ1

Cross-References