| Manufacturer part number (MPN) | XPSMCMCO0000UBG |
| EAN / GTIN | 3606480748530 |
| Sales unit | pcs |
| Range of product | Modicon MCM |
| Product or component type | Non-safe communication module |
| Device short name | XPSMCM |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
| Power dissipation in W | 3 W |
| Quality labels | CE |
| Range compatibility | Preventa XPSMCM |
| Connector type | mini B USB |
| Number of port | 1 |
| Method of access | Server |
| Transmission rate | 12 Mbit/s |
| Communication port protocol | USB |
| Current consumption | 0.125 mA |
| Maximum cable distance between devices | 5 m |
| Local signalling | LED green with CONNECT marking for operating |
| Connections - terminals | 2 spring clamp terminals, removable terminal block |
| Cable cross section | 0.2…2.5 mm² - 24 AWG...14 AWG flexible cablewithout cable end; 0.25…2.5 mm² - 23 AWG...14 AWG flexible cablewith cable end, with bezel; 0.25…2.5 mm² - 23 AWG...14 AWG flexible cablewith cable end, without bezel; 0.2…2.5 mm² - 24 AWG...14 AWG solid cablewithout cable end; 0.5…1 mm² - 20 AWG...18 AWG flexible cablewith cable end, with double bezel |
| Mounting support | Omega 35 mm DIN rail conforming to EN 50022 |
| Width | 22.5 mm |
| Height | 99 mm |
| Depth | 114.5 mm |
| Product weight | 0.3 kg |
| Product certifications | cULus; RCM; TÜV |
| IP degree of protection | IP20 |
| Ambient air temperature for operation | -10…55 °C |
| Ambient air temperature for storage | -20…85 °C |
| Relative humidity | 10…95 % |
| Pollution degree | 2 |
| Insulation | 250 V AC between power supply and housing conforming to IEC 61800-5-1 |
| Overvoltage category | II |
| Electromagnetic compatibility | Electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2; Electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2; Susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 61000-4-3; Susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3 |
| Vibration resistance | +/-0.35 mm (f= 10…55 Hz) conforming to IEC 61496-1 |
| Shock resistance | 10 gn (duration = 16 ms) for 1000 shocks on each axis conforming to IEC 61496-1 |
| Operating altitude | 2000 m |
| service life | 20 year(s) |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.5 cm |
| Package 1 Width | 12.8 cm |
| Package 1 Length | 16.4 cm |
| Package 1 Weight | 194.0 g |
| Unit Type of Package 2 | S01 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 15.0 cm |
| Package 2 Width | 15.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 1.337 kg |
| Warranty (in months) | 18 |
| Power consumption | 1.1 W |
| Certified for UL hazardous location division 1 | No |
| Certified for UL hazardous location division 2 | No |
| Certified for UL hazardous location group A (acetylene) | No |
| Certified for UL hazardous location group B (hydrogen) | No |
| Certified for UL hazardous location group C (ethylene) | No |
| Certified for UL hazardous location group D (propane) | No |
| Certified for UL hazardous location group E (metal dusts) | No |
| Certified for UL hazardous location class I | No |
| Certified for UL hazardous location class II | No |
| Certified for UL hazardous location class III | No |
| Supporting protocol for EtherCAT | No |
| Number of HW-interfaces USB | 1 |
| With optical interface | No |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for ASI | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | No |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for LON | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for other bus systems | Yes |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Mobile communications standard 3G (UMTS) | No |
| IO link master | No |
| Redundancy | No |
| Type of data transmission | Serial |
| With potential separation | No |
| SIL according to IEC 61508 | None |
| Suitable for safety functions | No |
| Performance level according to EN ISO 13849-1 | None |
| Appendant operation agent (Ex ia) | No |
| Explosion safety category for gas | None |
| Explosion safety category for dust | None |
| Country of origin | Italy |