Schneider Electric CANopen diagnostic expansion with spring term XPSMCMCO0000COG

Schneider Electric · Electrical Components · France · se.com
Part Number
XPSMCMCO0000COG  ·  HS 8536.90
Schneider Electric CANopen diagnostic expansion with spring term XPSMCMCO0000COG

Schneider Electric XPSMCMCO0000COG CANopen diagnostic expansion module for Modicon MCM with spring terminals.

Technical Specifications

Manufacturer part number (MPN)XPSMCMCO0000COG
EAN / GTIN3606480748332
Sales unitpcs
Range of productModicon MCM
Product or component typeNon-safe communication module
Device short nameXPSMCM
[Us] rated supply voltage24 V - 20...20 % DC
Power dissipation in W3 W
Quality labelsCE
Range compatibilityPreventa XPSMCM
Connector typemale SUB-D 9
Number of port1
Method of accessServer
Transmission rate10 kbit/s; 20 kbit/s; 50 kbit/s; 100 kbit/s; 125 kbit/s; 250 kbit/s; 500 kbit/s; 800 kbit/s; 1 Mbit/s; Autodetected
Communication port protocolCANopen
Current consumption0.125 mA
Maximum cable distance between devices2500 m; 1000 m; 750 m; 500 m; 250 m; 100 m; 50 m; 25 m
Local signallingLED green with PWR marking for power ON; LED green with RUN marking for operating; LED red with E IN marking for internal error; LED red with E EX marking for external error; LED green/red with OP marking for operating; LED green/red with ERR marking for communication error
Connections - terminals2 spring clamp terminals, removable terminal block
Cable cross section0.2…2.5 mm² - 24 AWG...14 AWG flexible cablewithout cable end; 0.25…2.5 mm² - 23 AWG...14 AWG flexible cablewith cable end, with bezel; 0.25…2.5 mm² - 23 AWG...14 AWG flexible cablewith cable end, without bezel; 0.2…2.5 mm² - 24 AWG...14 AWG solid cablewithout cable end; 0.5…1 mm² - 20 AWG...18 AWG flexible cablewith cable end, with double bezel
Mounting supportOmega 35 mm DIN rail conforming to EN 50022
Width22.5 mm
Height99 mm
Depth114.5 mm
Product weight0.3 kg
Product certificationscULus; RCM; TÜV
IP degree of protectionIP20
Ambient air temperature for operation-10…55 °C
Ambient air temperature for storage-20…85 °C
Relative humidity10…95 %
Pollution degree2
Insulation250 V AC between power supply and housing conforming to EN/IEC 61800-5-1
Overvoltage categoryII
Electromagnetic compatibilityElectrostatic discharge immunity test - test level: 6 kV (on contact) conforming to EN/IEC 61000-4-2; Electrostatic discharge immunity test - test level: 20 kV (on air) conforming to EN/IEC 61000-4-2; Susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to EN/IEC 61000-4-3; Susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3
Vibration resistance+/-0.35 mm (f= 10…55 Hz) conforming to EN/IEC 61496-1
Shock resistance10 gn (duration = 16 ms) for 1000 shocks on each axis conforming to EN/IEC 61496-1
Operating altitude2000 m
service life20 year(s)
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.5 cm
Package 1 Width12.8 cm
Package 1 Length16.2 cm
Package 1 Weight212.0 g
Unit Type of Package 2S01
Number of Units in Package 26
Package 2 Height15.0 cm
Package 2 Width15.0 cm
Package 2 Length40.0 cm
Package 2 Weight1.507 kg
Country of originIT
Warranty (in months)18
Number of HW-interfaces other1
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANYes
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Radio standard GPRSNo
Radio standard GSMNo
Mobile communications standard 3G (UMTS)No
IO link masterNo
RedundancyNo
Type of data transmissionSerial
With potential separationNo
SIL according to IEC 61508None
Suitable for safety functionsNo
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Explosion safety category for gasNone
Explosion safety category for dustNone