cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Schneider Electric TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 230 V AC coil LC2D65AP7

Schneider Electric · Electrical Components · Contactors · France · se.com
Part Number
LC2D65AP7  ·  HS 8536.49
Schneider Electric TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 230 V AC coil LC2D65AP7

Schneider Electric LC2D65AP7 Dreieretnv. 65A Elink 230VAC.

Technical Specifications

Manufacturer part number (MPN)LC2D65AP7 EAN / GTIN: 3389119409674 Sales unit: pcs Voltage: 230 V AC Range: TeSys; TeSys Deca Product name: TeSys D; TeSys Deca Product or component type: Reversing contactor Device short name: LC2D Contactor application: Motor control; Resistive load Utilisation category: AC-1; AC-3; AC-3e Device presentation: Preassembled with reversing power busbar Poles description: 3P power pole contact composition: 3 NO [Ue] rated operational voltage: Power circuit: <= 690 V AC 25...400 Hz; Power circuit: <= 300 V DC [Ie] rated operational current: 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit; 65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit Motor power kW: 18.5 kW at 220...230 V AC 50 Hz; 30 kW at 380...400 V AC 50 Hz; 37 kW at 415...440 V AC 50 Hz; 37 kW at 500 V AC 50 Hz; 37 kW at 660...690 V AC 50 Hz Motor power hp: 40 hp at 460/480 V AC 60 Hz for 3 phases motors; 5 hp at 115 V AC 60 Hz for 1 phase motors; 10 hp at 230/240 V AC 60 Hz for 1 phase motors; 20 hp at 200/208 V AC 60 Hz for 3 phases motors; 20 hp at 230/240 V AC 60 Hz for 3 phases motors; 50 hp at 575/600 V AC 60 Hz for 3 phases motors Control circuit type: AC at 50/60 Hz [Uc] control circuit voltage: 230 V AC 50/60 Hz Auxiliary contact composition: 1 NO + 1 NC [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947 Overvoltage category: III [Ith] conventional free air thermal current: 10 A (at 60 °C) for signalling circuit; 80 A (at 60 °C) for power circuit Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 1000 A at 440 V for power circuit conforming to IEC 60947 Rated breaking capacity: 1000 A at 440 V for power circuit conforming to IEC 60947 [Icw] rated short-time withstand current: 520 A 40 °C - 10 s for power circuit; 900 A 40 °C - 1 s for power circuit; 110 A 40 °C - 10 min for power circuit; 260 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit Associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1; 125 A gG at <= 690 V coordination type 1 for power circuit; 125 A gG at <= 690 V coordination type 2 for power circuit Average impedance: 1.5 mOhm - Ith 80 A 50 Hz for power circuit [Ui] rated insulation voltage: Power circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified Electrical durability: 1.45 Mcycles 65 A AC-3 at Ue <= 440 V; 1.4 Mcycles 80 A AC-1 at Ue <= 440 V; 1.45 Mcycles 65 A AC-3e at Ue <= 440 V Power dissipation per pole: 9.6 W AC-1; 6.3 W AC-3; 6.3 W AC-3e Front cover: With Interlocking type: Mechanical Mounting support: Rail; Plate Standards: CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60335-2-40:Annex JJ; IEC 60335-1 Product certifications: UL; CSA; RINA; GOST; CCC; DNV; LROS (Lloyds register of shipping); GL; BV; UKCA Connections - terminals: Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid; Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid; Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible without cable end; Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible without cable end; Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible with cable end; Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible with cable end; Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²solid; Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²solid Tightening torque: Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2; Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm; Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2; Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 Operating time: 4...19 ms opening; 12...26 ms closing Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 Mechanical durability: 6 Mcycles Maximum operating rate: 3600 cyc/h 60 °C Coil technology: Without built-in suppressor module Control circuit voltage limits: 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz Inrush power in VA: 140 VA 60 Hz cos phi 0.75 (at 20 °C); 160 VA 50 Hz cos phi 0.75 (at 20 °C) Hold-in power consumption in VA: 13 VA 60 Hz cos phi 0.3 (at 20 °C); 15 VA 50 Hz cos phi 0.3 (at 20 °C) Heat dissipation: 4…5 W at 50/60 Hz Auxiliary contacts type: type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 Signalling circuit frequency: 25...400 Hz minimum switching current: 5 mA for signalling circuit minimum switching voltage: 17 V for signalling circuit Non-overlap time: 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact Insulation resistance: > 10 MOhm for signalling circuit IP degree of protection: IP20 front face conforming to IEC 60529 Climatic withstand: conforming to IACS E10; conforming to IEC 60947-1 Annex Q category D Protective treatment: TH conforming to IEC 60068-2-30 Pollution degree: 3 Ambient air temperature for operation: -40…60 °C; 60…70 °C with derating Ambient air temperature for storage: -60…80 °C Operating altitude: 0...3000 m Fire resistance: 850 °C conforming to IEC 60695-2-1 Mechanical robustness: Vibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed: 4 Gn, 5...300 Hz; Shocks contactor open: 10 Gn for 11 ms; Shocks contactor closed: 15 Gn for 11 ms Height: 122 mm Width: 119 mm Depth: 120 mm Product weight: 1.89 kg Unit Type of Package 1: PCE Number of Units in Package 1: 1 Package 1 Height: 14.000 cm Package 1 Width: 16.500 cm Package 1 Length: 19.500 cm Package 1 Weight: 2.074 kg Unit Type of Package 2: S03 Number of Units in Package 2: 4 Package 2 Height: 30.000 cm Package 2 Width: 30.000 cm Package 2 Length: 40.000 cm Package 2 Weight: 8.777 kg Unit Type of Package 3: P06 Number of Units in Package 3: 16 Package 3 Height: 45.000 cm Package 3 Width: 60.000 cm Package 3 Length: 80.000 cm Package 3 Weight: 44.110 kg Country of origin: FR Warranty (in months): 18 Function: Reversing contactor Rated operation power at AC-3, 400 V: 30 kW Number of normally open contacts as main contact: 3 Number of auxiliary contacts as normally open contact: 1 Number of auxiliary contacts as normally closed contact: 1 Rated operation current Ie at AC-3, 400 V: 65 A Rated operation current Ie at AC-1, 400 V: 80 A Suitable for rail mounting: Yes Rated control supply voltage AC 50 Hz: 230 V Rated control supply voltage AC 60 Hz: 230 V Voltage type (operating voltage): AC Degree of protection (IP): IP20 Type of electrical connection of main circuit: Screw connection Operating voltage AC 50 Hz: 440 V Operating voltage AC 60 Hz: 440 V Voltage type for actuating: AC Rated operation power NEMA: 29.8 kW

Properties

MOQ1

Cross-References

Attached Documents