cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Passiva filter 6A 460V 60Hz (VW3A46158)

Schneider Electric · Filters & Strainers · Filter Elements · France · se.com
Part Number
VW3A46158  ·  HS 8548.90
Passiva filter 6A 460V 60Hz (VW3A46158)

Schneider Electric VW3A46158 Passiva filter 6A 460V 60Hz 5%THDi.

Technical Specifications

Manufacturer part number (MPN)VW3A46158
EAN / GTIN3606480652561
Sales unitpcs
Voltage460 V
Rated current6 A
Frequency60 Hz
Product or component typePassive filter
Product specific applicationReduction of current harmonics
Range compatibilityAltivar 71; Altivar 61; Altivar Process ATV600; Altivar Process ATV900
[Us] rated supply voltage480 V +/- 10 %
Supply frequency60 Hz +/- 2 %
Quantity per drive1 filter per drive for variable speed drive ATV61W motor: 0.75 kW/1 hp; 1 filter per drive for variable speed drive ATV61W motor: 1.5 kW/2 hp; 1 filter per drive for variable speed drive ATV61W motor: 2.2 kW/3 hp; 1 filter per drive for variable speed drive ATV61W motor: 3 kW; 1 filter per drive for variable speed drive ATV61H motor: 0.75 kW/1 hp; 1 filter per drive for variable speed drive ATV61H motor: 1.5 kW/2 hp; 1 filter per drive for variable speed drive ATV61H motor: 2.2 kW/3 hp; 1 filter per drive for variable speed drive ATV61H motor: 3 kW; 1 filter per drive for variable speed drive ATV71H motor: 0.75 kW/1 hp; 1 filter per drive for variable speed drive ATV71H motor: 1.5 kW/2 hp; 1 filter per drive for variable speed drive ATV71H motor: 2.2 kW/3 hp; 1 filter per drive for variable speed drive ATV71H motor: 3 kW; 1 filter per drive for variable speed drive ATV71P motor: 0.75 kW/1 hp; 1 filter per drive for variable speed drive ATV71P motor: 1.5 kW/2 hp; 1 filter per drive for variable speed drive ATV71P motor: 2.2 kW/3 hp; 1 filter per drive for variable speed drive ATV71P motor: 3 kW; 1 filter per drive for variable speed drive ATV71W motor: 0.75 kW/1 hp; 1 filter per drive for variable speed drive ATV71W motor: 1.5 kW/2 hp; 1 filter per drive for variable speed drive ATV71W motor: 2.2 kW/3 hp; 1 filter per drive for variable speed drive ATV71W motor: 3 kW; 1 filter per drive for variable speed drive ATV630 wall mount, motor: 0.75 kW/1 hp; 1 filter per drive for variable speed drive ATV630 wall mount, motor: 1.5 kW/2 hp; 1 filter per drive for variable speed drive ATV630 wall mount, motor: 2.2 kW/3 hp; 1 filter per drive for variable speed drive ATV630 wall mount, motor: 3 kW; 1 filter per drive for variable speed drive ATV650 wall mount, motor: 0.75 kW/1 hp; 1 filter per drive for variable speed drive ATV650 wall mount, motor: 1.5 kW/2 hp; 1 filter per drive for variable speed drive ATV650 wall mount, motor: 2.2 kW/3 hp; 1 filter per drive for variable speed drive ATV650 wall mount, motor: 3 kW; 1 filter per drive for variable speed drive ATV930 wall mount, motor: 0.75 kW/1 hp; 1 filter per drive for variable speed drive ATV930 wall mount, motor: 1.5 kW/2 hp; 1 filter per drive for variable speed drive ATV930 wall mount, motor: 2.2 kW/3 hp; 1 filter per drive for variable speed drive ATV930 wall mount, motor: 3 kW; 1 filter per drive for variable speed drive ATV950 wall mount, motor: 0.75 kW/1 hp; 1 filter per drive for variable speed drive ATV950 wall mount, motor: 1.5 kW/2 hp; 1 filter per drive for variable speed drive ATV950 wall mount, motor: 2.2 kW/3 hp; 1 filter per drive for variable speed drive ATV950 wall mount, motor: 3 kW
[In] rated current6 A for input; 6.2 A for output
Network number of phases3 phases
THDI10 % for variable speed drive ATV61H motor: 0.75 kW/1 hp; 10 % for variable speed drive ATV61H motor: 1.5 kW/2 hp; 10 % for variable speed drive ATV61H motor: 2.2 kW/3 hp; 10 % for variable speed drive ATV61H motor: 3 kW; 10 % for variable speed drive ATV71H motor: 0.75 kW/1 hp; 10 % for variable speed drive ATV71H motor: 1.5 kW/2 hp; 10 % for variable speed drive ATV71H motor: 2.2 kW/3 hp; 10 % for variable speed drive ATV71H motor: 3 kW; 10 % for variable speed drive ATV71P motor: 0.75 kW/1 hp; 10 % for variable speed drive ATV71P motor: 1.5 kW/2 hp; 10 % for variable speed drive ATV71P motor: 2.2 kW/3 hp; 10 % for variable speed drive ATV71P motor: 3 kW; 10 % for variable speed drive ATV71W motor: 0.75 kW/1 hp; 10 % for variable speed drive ATV71W motor: 1.5 kW/2 hp; 10 % for variable speed drive ATV71W motor: 2.2 kW/3 hp; 10 % for variable speed drive ATV71W motor: 3 kW; 5 % for variable speed drive ATV61W motor: 0.75 kW/1 hp; 5 % for variable speed drive ATV61W motor: 1.5 kW/2 hp; 5 % for variable speed drive ATV61W motor: 2.2 kW/3 hp; 5 % for variable speed drive ATV61W motor: 3 kW; 5 % for variable speed drive ATV630 motor: 0.75 kW/1 hp; 5 % for variable speed drive ATV630 motor: 1.5 kW/2 hp; 5 % for variable speed drive ATV630 motor: 2.2 kW/3 hp; 5 % for variable speed drive ATV630 motor: 3 kW; 5 % for variable speed drive ATV650 motor: 0.75 kW/1 hp; 5 % for variable speed drive ATV650 motor: 1.5 kW/2 hp; 5 % for variable speed drive ATV650 motor: 2.2 kW/3 hp; 5 % for variable speed drive ATV650 motor: 3 kW; 5 % for variable speed drive ATV930 motor: 0.75 kW/1 hp; 5 % for variable speed drive ATV930 motor: 1.5 kW/2 hp; 5 % for variable speed drive ATV930 motor: 2.2 kW/3 hp; 5 % for variable speed drive ATV930 motor: 3 kW; 5 % for variable speed drive ATV950 motor: 0.75 kW/1 hp; 5 % for variable speed drive ATV950 motor: 1.5 kW/2 hp; 5 % for variable speed drive ATV950 motor: 2.2 kW/3 hp; 5 % for variable speed drive ATV950 motor: 3 kW
Max current1.5 x nominal current (duration = 60 s)
Efficiency98 %
Thermal losses122 W
Cos phi1 (150 % of line current); 0.85 (75 % of line current); 0.99 (100 % of line current)
Electrical connectionX1-1...X2-3 terminal, connection capacity: 0.5...10 mm²; A, B terminal, connection capacity: 2.5 mm²
Electrical insulation classClass F
Product weight16 kg
IP degree of protectionIP20; IP55 (enclosure mounting)
Vibration resistance2 mm peak to peak (f= 5…13.2 Hz) conforming to IEC 60068-2-6; 0.7 gn (f= 13.2…150 Hz) conforming to IEC 60068-2-6
Relative humidity5…85 % without condensation
Ambient air temperature for operation45…60 °C (with current derating 3 % per °C); 5…45 °C (without current derating)
Ambient air temperature for storage-25…55 °C storage in original packaging; -25…65 °C during transport
Operating altitude1000...4000 m with current derating 5 % per 1000 m
StandardsIEC 61000-3-12; IEC 61000-2-4; IEC 61000-3-2; IEC 61000-3-4; G5/4 engineering recommendation; IEC 61000-2-2
Warranty (in months)18
Suitable as sinus filterNo
Suitable as du/dt-filterNo
Suitable as radio interference suppression filterNo
Suitable as audio frequency blockageNo
Number of poles, primary side3
Rated clock frequency8 kHz
Rated operating frequency0–100 Hz
Max. rated operation voltage Ue480 V
Rated current AC6 A
Degree of protection (IP)IP20
Country of originGermany

Properties

MOQ1

Cross-References

Attached Documents