| Manufacturer part number (MPN) | ATV340D18N4 EAN / GTIN: 3606480966965 Sales unit: pcs Voltage: 400 V Power: 18.5 kW Range of product: Altivar Machine ATV340 Product or component type: Variable speed drive Product specific application: Machine mounting mode: Cabinet mount Variant: Standard version Communication port protocol: Modbus serial Option card: Communication module, Profibus DP V1; Communication module, PROFINET; Communication module, DeviceNet; Communication module, CANopen; Communication module |
| EtherCAT Network number of phases | 3 phases Supply frequency: 50...60 Hz +/- 5 % [Us] rated supply voltage: 380...480 V - 15...10 % nominal output current: 39.0 A Motor power kW: 22 kW for normal duty; 18.5 kW for heavy duty Motor power hp: 30 hp for normal duty; 25 hp for heavy duty EMC filter: Class C3 EMC filter integrated IP degree of protection: IP20 Discrete input number: 5 Discrete input type: PTI programmable as pulse input: 0…30 kHz, 24 V DC (30 V); DI1...DI5 safe torque off, 24 V DC (30 V), impedance: 3.5 kOhm; programmable number of preset speeds: 16 preset speeds Discrete output number: 2.0 Discrete output type: Programmable output DQ1, DQ2 30 V DC 100 mA Analogue input number: 2 Analogue input type: AI1 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits; AI1 software-configurable temperature probe or water level sensor; AI1 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits; AI2 software-configurable voltage: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits Analogue output number: 1 Analogue output type: Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits; Software-configurable current AQ1: 0...20 mA impedance 500 Ohm, resolution 10 bits Relay output number: 2 output voltage: <= power supply voltage Relay output type: Relay outputs R1A; Relay outputs R1C electrical durability 100000 cycles; Relay outputs R2A; Relay outputs R2C electrical durability 100000 cycles Maximum switching current: Relay output R1C on resistive load, cos phi = 1: 3 A at 250 V AC; Relay output R1C on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC; Relay output R2C on resistive load, cos phi = 1: 5 A at 250 V AC; Relay output R2C on resistive load, cos phi = 1: 5 A at 30 V DC; Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC minimum switching current: Relay output R1B: 5 mA at 24 V DC; Relay output R2C: 5 mA at 24 V DC Physical interface: 2-wire RS 485 Connector type: 1 RJ45 Method of access: Slave Modbus RTU Transmission rate: 4.8 kbit/s; 9.6 kbit/s; 19.2 kbit/s; 38.4 kbit/s Transmission frame: RTU Number of addresses: 1…247 Data format: 8 bits, configurable odd, even or no parity Type of polarization: No impedance 4 quadrant operation possible: True Asynchronous motor control profile: Optimized torque mode; Variable torque standard; Constant torque standard Synchronous motor control profile: Reluctance motor; Permanent magnet motor Pollution degree: 2 conforming to IEC 61800-5-1 Maximum output frequency: 0.599 kHz Acceleration and deceleration ramps: S, U or customized; Linear adjustable separately from 0.01...9999 s Motor slip compensation: Adjustable; Automatic whatever the load; Can be suppressed; Not available in permanent magnet motor law Switching frequency: 2...16 kHz adjustable; 4...16 kHz with derating factor Nominal switching frequency: 4 kHz Braking to standstill: By DC injection Brake chopper integrated: True Line current: 43.4 A at 380 V (normal duty); 35.0 A at 480 V (normal duty); 54.7 A at 380 V (heavy duty); 43.4 A at 480 V (heavy duty) Maximum input current: 54.7 A Maximum output voltage: 480 V Apparent power: 33.4 kVA at 480 V (normal duty); 36.1 kVA at 480 V (heavy duty) Maximum transient current: 50.6 A during 60 s (normal duty); 59 A during 60 s (heavy duty); 62.1 A during 2 s (normal duty); 70 A during 2 s (heavy duty) Electrical connection: Screw terminal, clamping capacity: 0.2...2.5 mm² for control; Screw terminal, clamping capacity: 10...25 mm² for line side; Screw terminal, clamping capacity: 10...25 mm² for DC bus; Screw terminal, clamping capacity: 6...25 mm² for motor Prospective line Isc: 22 kA Base load current at high overload: 39.0 A Base load current at low overload: 46.0 A Power dissipation in W: Natural convection: 21 W at 380 V, switching frequency 4 kHz (heavy duty); Forced convection: 410 W at 380 V, switching frequency 4 kHz (heavy duty); Natural convection: 23 W at 380 V, switching frequency 4 kHz (normal duty); Forced convection: 464 W at 380 V, switching frequency 4 kHz (normal duty) With safety function Safely Limited Speed (SLS): True With safety function Safe brake management (SBC/SBT): True With safety function Safe Operating Stop (SOS): False With safety function Safe Position (SP): False With safety function Safe programmable logic: False With safety function Safe Speed Monitor (SSM): False With safety function Safe Stop 1 (SS1): True With sft fct Safe Stop 2 (SS2): False With safety function Safe torque off (STO): True With safety function Safely Limited Position (SLP): False With safety function Safe Direction (SDI): False Protection type: Thermal protection: motor; Safe torque off: motor; Motor phase loss: motor; Thermal protection: drive; Safe torque off: drive; Overheating: drive; Overcurrent: drive; Output overcurrent between motor phase and earth: drive; Output overcurrent between motor phases: drive; Short-circuit between motor phase and earth: drive; Short-circuit between motor phases: drive; Motor phase loss: drive; DC Bus overvoltage: drive; Line supply overvoltage: drive; Line supply undervoltage: drive; Input supply loss: drive; Exceeding limit speed: drive; Break on the control circuit: drive Width: 180.0 mm Height: 385.0 mm Depth: 249.0 mm Product weight: 10.2 kg Continuous output current: 46 A at 4 kHz for normal duty; 39 A at 4 kHz for heavy duty Operating altitude: <= 3000 m with current derating above 1000m Operating position: Vertical +/- 10 degree Product certifications: UL; CSA; TÜV; EAC; CTick Marking: CE Standards: IEC 61800-3; IEC 61800-5-1; IEC 60721-3; IEC 61508; IEC 13849-1; UL 618000-5-1; UL 508C Assembly style: With heat sink Electromagnetic compatibility: Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Environmental class (during operation): Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3 Maximum acceleration under shock impact (during operation): 70 m/s² at 22 ms Maximum deflection under vibratory load (during operation): 1.5 mm at 2...9 Hz Permitted relative humidity (during operation): Class 3K5 according to EN 60721-3 Volume of cooling air: 128.0 m3/h Type of cooling: Forced convection Overvoltage category: Class III Regulation loop: Adjustable PID controller Noise level: 56.7 dB Ambient air transport temperature: -40…70 °C Ambient air temperature for operation: -15…50 °C without derating (vertical position); 50…60 °C with derating factor (vertical position) Ambient air temperature for storage: -40…70 °C Isolation: Between power and control terminals Number of Units in Package 1: 1 Number of Units in Package 2: 2 Country of origin: ID Warranty (in months): 18 With control element: No Number of digital inputs: 5 Number of digital outputs: 2 Number of analogue inputs: 2 Number of analogue outputs: 1 Supporting protocol for LON: No Number of HW-interfaces RS-485: 1 Number of HW-interfaces other: 1 With optical interface: No Supporting protocol for TCP/IP: No Supporting protocol for ASI: No Supporting protocol for PROFIBUS: Yes Supporting protocol for CAN: Yes Supporting protocol for INTERBUS: No Supporting protocol for KNX: No Supporting protocol for Modbus: Yes Supporting protocol for Data-Highway: No Supporting protocol for DeviceNet: Yes Supporting protocol for SUCONET: No Supporting protocol for other bus systems: Yes Degree of protection (IP): IP20 With PC connection: Yes Supporting protocol for SERCOS: No Supporting protocol for INTERBUS-Safety: No Mains voltage: 380–480 V Mains frequency: 50/60 Hz Type of converter: U converter Number of phases output: 3 Number of phases input: 3 Integrated breaking resistance: No Application in industrial area permitted: Yes Application in domestic- and commercial area permitted: No Max. output frequency: 599 Hz Max. output at linear load at rated output voltage: 18.5 kW Max. output at quadratic load at rated output voltage: 18.5 kW Relative symmetric net voltage tolerance: 10 % Relative symmetric net frequency tolerance: 5 % Supporting protocol for AS-Interface Safety at Work: No Supporting protocol for DeviceNet Safety: No Supporting protocol for EtherNet/IP: No Supporting protocol for Foundation Fieldbus: No Supporting protocol for PROFINET CBA: No Supporting protocol for PROFINET IO: Yes Supporting protocol for PROFIsafe: No Supporting protocol for SafetyBUS p: No Max. output voltage: 480 V Nominal output current I2N: 49.9 A Supporting protocol for BACnet: No |