Schneider Electric RM22TR33 Modular 3-Phase control relay, 8 A, 2 CO, 380...480 V AC

Schneider Electric · Control & Automation · Relays & Timers · France · se.com
Part Number
RM22TR33  ·  HS 8536.49
Schneider Electric RM22TR33 Modular 3-Phase control relay, 8 A, 2 CO, 380...480 V AC

Schneider Electric RM22TR33 — Modular 3-phase control relay, 8 A, 2 CO, 380.480 V AC.

Technical Specifications

Manufacturer part number (MPN)RM22TR33 EAN / GTIN: 3606480792199 Sales unit: pcs Package quantity: 40 pcs Range of product: Harmony Control Relays Relay type: Control relay Product or component type: 3-phase control relay Network number of phases: 3 phases Relay name: RM22TR Relay monitored parameters: Overvoltage and undervoltage detection; Phase sequence; Phase failure detection Time delay type: Adjustable 0.1...30 s, +/- 10 % of the full scale value Tt- time delay upon fault Switching capacity in VA: 2000 VA Measurement range: 380...480 V voltage AC Contacts type and composition: 2 C/O Reset time: 1500 ms at maximum voltage Maximum switching voltage: 250 V AC minimum switching current: 10 mA at 5 V DC Maximum switching current: 8 A AC Supply voltage limits: 304…576 V AC Power consumption in VA: 15 VA at 480 V AC 60 Hz Voltage detection threshold: < 100 V AC supply voltage frequency: 50...60 Hz +/- 10 % Output contacts: 2 C/O nominal output current: 8 A Setting accuracy of the switching threshold: +/- 10 % of the full scale Setting accuracy of time delay: 10 % Maximum measuring cycle: 150 ms measurement cycle as true rms value Threshold adjustment voltage: 2...20 % of Un selected Repeat accuracy: +/- 0.5 % for input and measurement circuit; +/- 3 % for time delay Measurement error: < 1 % over the whole range with voltage variation; < 0.05 %/°C with temperature variation Response time: <= 300 ms Overvoltage category: III conforming to IEC 60664-1; III conforming to UL 508 Insulation resistance: > 100 MOhm at 500 V DC conforming to IEC 60255-27 Connections - terminals: Screw terminals, 2 x 0.5...2 x 2.5 mm² (20 AWG...14 AWG) solid without cable end; Screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) flexible with cable end; Screw terminals, 1 x 0.5...1 x 3.3 mm² (20 AWG...12 AWG) solid without cable end; Screw terminals, 1 x 0.2...1 x 2.5 mm² (24 AWG...14 AWG) flexible with cable end Tightening torque: 0.6…1 N.m conforming to IEC 60947-1 Housing material: Polycarbonate Local signalling: LED (yellow) relay ON; LED (green) power ON Mounting support: 35 mm DIN rail conforming to IEC 60715 Electrical durability: 100000 cycles Mechanical durability: 10000000 cycles Utilisation category: AC-15 conforming to IEC 60947-5-1; DC-13 conforming to IEC 60947-5-1; AC-1 conforming to IEC 60947-4-1; DC-1 conforming to IEC 60947-4-1 [Un] rated nominal voltage: self-powered Reliability data: MTTFd = 388.1 years; B10d = 350000 Contacts material: Cadmium free Control type: With test button Width: 22.5 mm; 22.9 mm Height: 90 mm; 88.9 mm Depth: 73 mm; 73.7 mm Product weight: 0.095 kg; 0.10 kg Electromagnetic compatibility: Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1; Immunity for industrial environments conforming to IEC 61000-6-2; Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3; Emission standard for industrial environments conforming to IEC 61000-6-4; Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2; Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Standards: IEC 60255-1 Product certifications: GL; CSA; RCM; CE; EAC; CCC; UL Ambient air temperature for storage: -40…70 °C; -40…70 °C Ambient air temperature for operation: -20…50 °C at 60 Hz; -20…60 °C at 50 Hz AC/DC Relative humidity: 93…97 % at 25…55 °C conforming to IEC 60068-2-30 Vibration resistance: 0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6; 1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6; 0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6; 0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6 Shock resistance: 15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27; 5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27 IP degree of protection: IP20 (terminals) conforming to IEC 60529; IP40 (housing) conforming to IEC 60529; IP50 (front panel) conforming to IEC 60529 Pollution degree: 3 conforming to IEC 60664-1; 3 conforming to UL 508 Dielectric test voltage: 2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27 Unit Type of Package 1: PCE Number of Units in Package 1: 1 Package 1 Height: 3.100 cm Package 1 Width: 8.800 cm Package 1 Length: 10.000 cm Package 1 Weight: 106.000 g Unit Type of Package 2: S02 Number of Units in Package 2: 40 Package 2 Height: 15.000 cm Package 2 Width: 30.000 cm Package 2 Length: 40.000 cm Package 2 Weight: 4.692 kg Unit Type of Package 3: P06 Number of Units in Package 3: 640 Package 3 Height: 75.000 cm Package 3 Width: 60.000 cm Package 3 Length: 80.000 cm Package 3 Weight: 81.060 kg Country of origin: ID Warranty (in months): 18 Type of electric connection: Screw connection With detachable clamps: No Rated control supply voltage AC 50 Hz: 380–480 V Rated control supply voltage AC 60 Hz: 380–480 V Voltage type for actuating: AC Phase sequence monitoring: Yes Phase failure detection: Yes Function under voltage detection: Yes Function overvoltage detection: Yes Phase imbalance monitoring: No Voltage measuring range: 304–576 V Min. adjustable delay-on energization time: 0.1 s Max. permitted delay-on energization time: 30 s Min. adjustable off-delay time: 0.1 s Max. permitted off-delay time: 30 s Number of contacts as change-over contact: 2

Properties

MOQ1

Cross-References

Attached Documents