| Manufacturer part number (MPN) | LTMR100EBD |
| EAN / GTIN | 3389119404907 |
| Sales unit | pcs |
| Package quantity | 10 pcs |
| Voltage | 24 V DC |
| Setting range | 5-100 A |
| Range | TeSys |
| Product name | TeSys T |
| Device short name | LTMR |
| Product or component type | Motor controller |
| Device application | Equipment monitoring and control |
| Measurement current | 5…100 A |
| [Us] rated supply voltage | 24 V DC |
| Current consumption | 56...127 mA |
| Supply voltage limits | 20.4…26.24 V DC |
| Communication port protocol | Modbus TCP/EtherNet/IP |
| Bus type | Ethernet IEEE 802.3 interface, addressing 0...159, transmission rate 10...100 Mbit/s, RJ45 with 2 shielded twisted pairs |
| [Ui] rated insulation voltage | 690 V conforming to EN/IEC 60947-1; 690 V conforming to CSA C22.2 No 14; 690 V conforming to UL 508 |
| [Uimp] rated impulse withstand voltage | 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1; 0.8 kV communication circuit conforming to EN/IEC 60947-4-1; 0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 |
| Short-circuit withstand | 100 kA conforming to EN/IEC 60947-4-1 |
| Associated fuse rating | 4 A gG for output; 0.5 A gG for control circuit |
| Protection type | Locked rotor; Overload; Thermal overload protection; Earth-leakage protection; Reverse polarity protection; Overload (long time); Power factor variation; Phase unbalance; Load fluctuation; Phase failure; Thermal protection |
| Network and machine diagnosis type | Fault recording; Trip context information; Waiting time after overload tripping; Trip history information; Running hours counter/operating time; Motor control command recording; Starting current and time; Phase fault and earth fault trip counters; Event recording; Remaining operating time before overload tripping |
| Logic input number | 6 |
| Input current | 7 mA |
| Current state 0 guaranteed | Logic input: < 5 V and <= 15 mA for 5 ms |
| Current state 1 guaranteed | Logic input: < 15 V and 2...15 mA for 15 ms |
| maximum output switching frequency | 2 Hz |
| Load current | 5 A at 250 V AC for logic output; 5 A at 30 V DC for logic output |
| Permissible power | 480 VA (AC-15), Ie = 2 A, 500000 cycles (output); 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output) |
| maximum operating rate | 1800 cyc/h |
| Contacts type and composition | 1 NO + 1 NC fault signal; 3 NO |
| Metering type | Average current Iavg; Earth-fault current; Temperature; Phase current I1, I2, I3 RMS; Imbalance current |
| Measurement accuracy | 5...15 % earth fault current internal measurement; 1 % voltage (100...830 V); 3 % power factor; 5 % earth fault current external measurement; +/- 30 min/year internal clock; 0,02 temperature; 5 % active and reactive power; 0,02 current |
| Overvoltage category | III |
| Connection pitch | 5.08 mm |
| Connections - terminals | Control circuit: connector 1 cable(s) 0.25…2.5 mm² (24 AWG...14 AWG) flexible with cable end; Control circuit: connector 1 cable(s) 0.2…2.5 mm² (24 AWG...14 AWG) flexible without cable end; Control circuit: connector 1 cable(s) 0.25…2.5 mm² (24 AWG...14 AWG) flexible without cable end; Control circuit: connector 1 cable(s) 0.2…2.5 mm² (24 AWG...14 AWG) solid without cable end; Control circuit: connector 2 cable(s) 0.2…1 mm² (24 AWG...14 AWG) flexible with cable end; Control circuit: connector 2 cable(s) 0.2…1.5 mm² (24 AWG...14 AWG) flexible without cable end; Control circuit: connector 2 cable(s) 0.5…1.5 mm² (24 AWG...14 AWG) flexible without cable end; Control circuit: connector 2 cable(s) 0.2…1 mm² (24 AWG...14 AWG) solid without cable end |
| Tightening torque | Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm |
| Pollution degree | 3 |
| Electromagnetic compatibility | Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2; Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3; Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4; Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4; Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11; Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6; Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5; Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5; Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5; Control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5; Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5; Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5; Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 |
| Width | 91 mm |
| Height | 61 mm |
| Depth | 122.5 mm |
| Product weight | 0.53 kg |
| Web services | Web server |
| Compatibility code | LTMR |
| Standards | IEC 60947-4-1; UL 508; IACS E10; EN 60947-4-1; CSA C22.2 No 14 |
| Product certifications | C-Tick; KERI; BV; ABS; NOM; LROS (Lloyds register of shipping); RMRoS; RINA; GL; DNV; ATEX; CCC; EAC; UL; CSA |
| Protective treatment | 12 x 24 hour cycles conforming to EN/IEC 60068-2-30; 48 h conforming to EN/IEC 60070-2-11; TH conforming to EN/IEC 60068 |
| Fire resistance | 650 °C conforming to EN/IEC 60695-2-12; 960 °C conforming to UL 94 |
| Ambient air temperature for operation | -20…60 °C |
| Ambient air temperature for storage | -40…80 °C |
| Operating altitude | <= 2000 m without derating |
| Mechanical robustness | Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6; Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6; Shocks half its wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27 |
| IP degree of protection | IP20 |
| Country of origin | CN |
| Warranty (in months) | 18 |
| Supply voltage DC | 20.4–26.24 V |
| Voltage type (supply voltage) | DC |
| Rated operation current Ie | 5–100 A |
| Rated voltage Ue at DC | 20.4–26.24 V |
| Current detection module | Yes |
| Voltage detection module | No |
| Type of connection system | Screw connection |
| Rated control supply voltage DC | 24 V |
| Voltage type for actuating | DC |
| Number of outputs, with contact | 5 |
| Number of electronic outputs | 3 |
| Input for thermistor connection | Yes |
| Input for earth fault detection | Yes |
| Input for analogue temperature sensor | Yes |
| Degree of protection (IP) | IP20 |
| Number of digital inputs | 6 |