cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Schneider Electric Add-on residual current device, ACTI9 Vigi C120, 3P, 125A, A type, instantaneous, 30MA, 400...415VAC A9N18575

Schneider Electric · Electrical Components · RCDs & RCBOs · France · se.com
Part Number
A9N18575  ·  HS 8536.30
Schneider Electric Add-on residual current device, ACTI9 Vigi C120, 3P, 125A, A type, instantaneous, 30MA, 400...415VAC A9N18575

Schneider Electric A9N18575 Residual current module Vigi C120 3P 125A 30mA A.

Technical Specifications

Manufacturer part number (MPN)A9N18575
EAN / GTIN3606480376382
Sales unitpcs
Package quantity8 pcs
Rated current125 A
Number of poles3P
RangeActi9
Product nameActi9 Vigi C120
Product or component typeAdd-on residual current device
Device short nameVigi C120
Poles description3P
[In] rated current125 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType A
StandardsEN 61009; IEC/EN 61009-2-1
Device location in systemOutgoer; Group incomer
Network frequency50/60 Hz
[Ue] rated operational voltage400...415 V AC 50/60 Hz
Residual current tripping technologyVoltage independent
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
mounting modeClip-on
Mounting support35 mm symmetrical DIN rail
Electrical connection to mcbBy screws
9 mm pitches10
Height95 mm
Width171 mm
Depth73 mm
Product weight0.5 kg
ColourWhite
Mechanical durability20000 cycles
Connections - terminalsTunnel type terminals 1…35 mm² flexible; Tunnel type terminals 1…50 mm² rigid
Wire stripping length15 mm
Tightening torque3.5 N.m
IP degree of protectionIP20
Pollution degree3 conforming to IEC 60947-2
Ambient air temperature for operation-25…60 °C
Ambient air temperature for storage-40…60 °C
Warranty (in months)18
Power loss3.6 W
Nominal voltage400–415 V
Nominal current125 A
Rated fault current adjustableNo
Rated fault current0.03 A
Delay adjustableNo
Leakage current typeA
Surge current capacity0.25 kA
Frequency50/60 Hz
Rated insulation voltage Ui500 V
Rated impulse withstand voltage Uimp6 kV
Connectable conductor cross section solid-core1–50 mm²
Connectable conductor cross section multi-wired1–35 mm²
Anti-nuisance tripping versionNo
With interlocking deviceNo
Degree of protection (IP)IP20
Ambient temperature during operating-25–60 °C
Country of originFrance

Properties

MOQ1

Cross-References

Attached Documents