Schneider Electric ISFL160 direct 100mm busbar terminal 95mm² - fuse switch-disconnector LV480853

Schneider Electric · Switchgear & Protection · Fuse Switch-Disconnectors · France · se.com
Part Number
LV480853  ·  HS 8536.50
Schneider Electric ISFL160 direct 100mm busbar terminal 95mm² - fuse switch-disconnector LV480853

Schneider Electric LV480853 ISFL160 3P f.rails c-c=100mm.

Technical Specifications

Manufacturer part number (MPN)LV480853
EAN / GTIN3606480341113
Sales unitpcs
Package quantity11 pcs
Number of poles3P
Conductor cross-section95 mm²
RangeFuPacT
Product nameFuPacT ISFL
Device short nameISFL160
Product or component typeFuse-switch disconnector
Device applicationEquipment protection, monitoring and control; Distribution
Signalling functionSeparated fuse monitor
Poles description1 x 3P switchable
Number of fuse carriers3
Fuse typeDIN
Fuse sizeNH00; NH000
Suitability for isolationYes conforming to EN/IEC 60947-3
Visible breakYes
Contact position indicatorYes
[Ith] conventional free air thermal current160 A ( 40 °C ) power dissipation per fuse: 12 W
[Ithe] conventional enclosed thermal current160 A at 40 °C
Power dissipation per fuse12 W
Maximum power dissipation per pole19 W
[Ue] rated operational voltage690 V AC 50/60 Hz; 800 V AC 50/60 Hz AC-20; 800 V DC DC-20
[Ui] rated insulation voltage1000 V AC 50/60 Hz; 1000 V DC
[Uimp] rated impulse withstand voltage8 kV
[Ie] rated operational currentAC-22B: 160 A at 220/240 V AC 50/60 Hz; AC-22B: 160 A at 380/415 V AC 50/60 Hz; AC-22B: 160 A at 440/480 V AC 50/60 Hz; AC-22B: 160 A at 500 V AC 50/60 Hz; AC-22B: 100 A at 660/690 V AC 50/60 Hz; AC-23B: 160 A at 220/240 V AC 50/60 Hz; AC-23B: 160 A at 380/415 V AC 50/60 Hz
[Iq] Breaking capacity with fuses (kA RMS)100 kA at 415 V (AC); 100 kA at 500 V (AC); 100 kA at 690 V (AC)
[Icw] rated short-time withstand current5 kA for 1 s
[Icm] Rated short-circuit making capacity7.65 kA at 690 V
Rated dutyUninterrupted
Control typeFuse carriers handle
Provision for padlocking3 padlocks
Mounting positionHorizontal; Vertical
mounting modeFixed
Mounting supportBusbars
Mounting locationOne above the other
Contact operationSingle-break
Mechanical durability1400 cycles
Electrical durabilityAC-21B: 200 cycles 690 V AC 50/60 Hz; AC-22B: 200 cycles 500 V AC 50/60 Hz; AC-23B: 200 cycles 415 V AC 50/60 Hz
Connections - terminalsCable connectors 95 mm²
Tightening torque14 N.m
Width50 mm
Height405 mm
Depth123 mm
Product weight1.3 kg
StandardsEN/IEC 60947-1; EN/IEC 60947-3
Product certificationsCE; CCC; EAC
Electrical shock protection classClass II front face
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Ambient air temperature for operation-20…70 °C
Ambient air temperature for storage-50…85 °C
Warranty (in months)18
Rated permanent current Iu160 A
Conditioned rated short-circuit current Iq100 kA
Degree of protection (IP), front sideIP20
Suitable for fusesNH000, NH00
Type of electrical connection of main circuitScrew connection
Rated short-time withstand current lcw5 kA
Suitable for floor mountingNo
Suitable for front mountingYes
Max. rated operation voltage Ue AC690 V
Position control elementFront side
Country of originGermany

Properties

MOQ1

Cross-References