| Manufacturer part number (MPN) | A9TDE3616 |
| EAN / GTIN | 3606481906502 |
| HS code | 8536.90 |
| Sales unit | pcs |
| Package quantity | 24 pcs |
| Rated current | 16 A |
| Range | Acti9 |
| Product name | Acti9 iCV40 ARC |
| Product or component type | Arc fault detection RCBO |
| Device short name | iCV40N ARC |
| Product specific application | Arc fault detection |
| Standards | EN/IEC 62606; EN/IEC 61009-1; EN/IEC 60947-2; EN/IEC 61009-2-1 |
| Poles description | 1P + N |
| Number of protected poles | 1 |
| Curve code | B |
| Breaking capacity code | N |
| Breaking capacity | 6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1; 10 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2 |
| Rated breaking and making capacity | Idm 3000 A at 230 V AC 50 Hz conforming to IEC 61009-2-1 |
| Neutral position | Left |
| Network type | AC |
| Earth-leakage protection time delay | Instantaneous |
| Earth-leakage protection class | Type A-SI (Super Immunised) |
| Electrical data recording | Date and time; Maintenance indicators |
| Suitability for isolation | Yes |
| Residual current tripping technology | Voltage independent |
| Trip unit technology | Thermal-magnetic |
| Earth-leakage protection | Integrated |
| [In] rated current | 16 A |
| Network frequency | 50 Hz |
| [Ue] rated operational voltage | 230 V AC 50 Hz |
| Device location in system | Outgoer |
| Magnetic tripping limit | 3...5 x In |
| [Ics] rated service breaking capacity | 6000 A AC 50 Hz conforming to EN/IEC 61009-2-1; 7.5 kA AC 50 Hz conforming to EN/IEC 60947-2 |
| Limitation class | 3 |
| [Ui] rated insulation voltage | 250 V AC 50 Hz between phase and neutral |
| Threshold tripping voltage | 275 V for +/- 5 V |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Contact position indicator | Yes |
| Control type | Toggle |
| Local signalling | ON, OFF, fault trip; LED arc fault diagnostic |
| mounting mode | Clip-on |
| Mounting support | DIN rail |
| Colour | White (RAL 9003) |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles 230 V AC 50 Hz |
| Overvoltage category | III |
| Locking options description | Padlocking device |
| cable entry | Top and bottom |
| Connections - terminals | Tunnel type terminal 1…16 mm² rigid; Tunnel type terminal 1…10 mm² flexible |
| Wire stripping length | 14 mm |
| Tightening torque | 2 N.m |
| Comb busbar and distribution block compatibility | YES |
| 9 mm pitches | 4 |
| Height | 91 mm |
| Width | 36 mm |
| Depth | 73 mm |
| Product weight | 220 g |
| Total power losses | 3.408 W |
| Power losses per pole | 2.65 W |
| Power losses on neutral | 0.763 W |
| Earth-leakage sensitivity | 30 mA |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Pollution degree | 2 conforming to EN/IEC 62606 |
| Tropicalisation | Severity B conforming to IEC 60068-2-30 for 28 d |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 2000 m |
| Ambient air temperature for operation | -25…50 °C |
| Ambient air temperature for storage | -40…80 °C |
| Quality labels | OVE |
| Warranty (in months) | 18 |