| Manufacturer part number (MPN) | A9XMC1D3 EAN / GTIN: 3606489749118 Sales unit: pcs Package quantity: 80 pcs Voltage: 230 V Range: PowerTag Product or component type: Input and ouput module Device short name: PowerTag C IO 230V Product name: PowerTag Control Concentrator compatibility: Acti9 PowerTag Link C; Wiser IP module; Acti9 PowerTag Link; Acti9 PowerTag Link HD Range compatibility: Acti9 impulse relay; Acti9 contactor; Acti9 iACTs remote indication auxiliary; Acti9 iATLs remote indication auxiliary Communication mode: Radio frequency 2.4…2.4835 GHz IEEE 802.15.4 [Us] rated supply voltage: 230 V AC (+/- 20 %) Network frequency: 50/60 Hz Power consumption in VA: 2 VA digital input number: 1 Input type: Dry contact 230 V AC 2 mA Voltage state 1 guaranteed: >= 164 V for digital input Voltage state 0 guaranteed: <= 40 V for digital input Current state 1 guaranteed: >= 2 mA (digital input) Current state 0 guaranteed: <= 0.5 mA (digital input) digital output number: 1 Output type: Dry contact 230 V 0.01...2 A AC Discrete output type: Configurable relay logic Output function: NO/NC programmable Mechanical durability: 100000 cycles for output mounting mode: Clip-on Mounting support: DIN rail Local signalling: Green, orange and red LED for product status Impulse duration: 300 ms by default - 0 ms, + 300 ms Time between 2 impulse: 100 ms minimum - tolerance: - 0 ms, + 300 ms Colour: White (RAL 9003) 9 mm pitches: 2 Height: 85 mm material: PA6 GF30 Width: 18 mm Depth: 62 mm Product weight: 80 g Connections - terminals: Tunnel type terminals (top) - 1 cable(s) 1…16 mm² (18 AWG...16 AWG) - rigid; Tunnel type terminals (top) - 1 cable(s) 0.5…10 mm² (21 AWG...8 AWG) - flexible; Tunnel type terminals (bottom) - 1 cable(s) 1…6 mm² (18 AWG...10 AWG) - rigid; Tunnel type terminals (bottom) - 1 cable(s) 0.5…4 mm² (21 AWG...12 AWG) - flexible; Tunnel type terminals (bottom) - 1 cable(s) 0.5…4 mm² (21 AWG...12 AWG) - flexible with ferrule; Tunnel type terminals (bottom) - 2 cable(s) 1.5…2.5 mm² (16 AWG...14 AWG) - rigid; Tunnel type terminals (bottom) - 2 cable(s) 1.5…2.5 mm² (16 AWG...14 AWG) - flexible Wire stripping length: 14 mm for top connection; 9 mm for bottom connection Tightening torque: Power supply: 2 N.m top; digital input/output: 1 N.m bottom Standards: EN/IEC 61010-1; ETSI EN 300 328; EN/IEC 62479; ETSI EN 301 489-17; ETSI EN 301 489-1; EN/IEC 61010-2-201; EN/IEC 61326-1 IP degree of protection: IP20 casing: conforming to IEC 60529; IP40 front face: conforming to IEC 60529 Pollution degree: 3 Overvoltage category: III conforming to IEC 61010-1 IK degree of protection: IK05 Relative humidity: 0…93 % at 40 °C conforming to IEC 60068-2-78 Operating altitude: 0...2000 m Ambient air temperature for operation: -25…60 °C Ambient air temperature for storage: -40…85 °C Fire resistance: 960 °C / 30 s conforming to UL 94 V0 Number of Units in Package 1: 1 Number of Units in Package 2: 80 Warranty (in months): 18 Certified for UL hazardous location division 1: No Certified for UL hazardous location division 2: No Certified for UL hazardous location group A (acetylene): No Certified for UL hazardous location group B (hydrogen): No Certified for UL hazardous location group C (ethylene): No Certified for UL hazardous location group D (propane): No Certified for UL hazardous location group E (metal dusts): No Certified for UL hazardous location class I: No Certified for UL hazardous location class II: No Certified for UL hazardous location class III: No Supporting protocol for EtherCAT: No Voltage type (supply voltage): AC Number of digital inputs: 1 Number of digital outputs: 1 digital outputs configurable: Yes Input current at signal 1: 2 mA Type of voltage (input voltage): AC Type of digital output: Relay Output current: 2 A Type of output voltage: AC Number of HW-interfaces wireless: 1 With optical interface: No Supporting protocol for TCP/IP: No Supporting protocol for PROFIBUS: No Supporting protocol for CAN: No Supporting protocol for INTERBUS: No Supporting protocol for ASI: No Supporting protocol for KNX: No Supporting protocol for Modbus: No Supporting protocol for Data-Highway: No Supporting protocol for DeviceNet: No Supporting protocol for SUCONET: No Supporting protocol for LON: No Supporting protocol for PROFINET IO: No Supporting protocol for PROFINET CBA: No Supporting protocol for SERCOS: No Supporting protocol for Foundation Fieldbus: No Supporting protocol for EtherNet/IP: No Supporting protocol for AS-Interface Safety at Work: No Supporting protocol for DeviceNet Safety: No Supporting protocol for INTERBUS-Safety: No Supporting protocol for PROFIsafe: No Supporting protocol for SafetyBUS p: No Supporting protocol for other bus systems: No Radio standard Bluetooth: No Radio standard WLAN 802.11: No Radio standard GPRS: No Radio standard GSM: No Mobile communications standard 3G (UMTS): No IO link master: No System accessory: No Degree of protection (IP): IP20 Type of electric connection: Screw connection Fieldbus connection over separate bus coupler possible: No Suitable for rail mounting: Yes Wall mounting/direct mounting: Yes Front built-in possible: No Rack-assembly possible: No Suitable for safety functions: No SIL according to IEC 61508: None Performance level according to EN ISO 13849-1: None Appendant operation agent (Ex ia): No Explosion safety category for gas: None Explosion safety category for dust: None Country of origin: Estonia |