cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Schneider Electric Vigilohm IFL12 Insulation Fault Locator 12-Channel (IMDIFL12)

Schneider Electric · Electrical Components · France · se.com
Part Number
IMDIFL12  ·  HS 9030.39
Schneider Electric Vigilohm IFL12 Insulation Fault Locator 12-Channel (IMDIFL12)

Schneider Electric IMDIFL12 is the Vigilohm IFL12 insulation fault locator for IT and HRG earthing systems on 0-1000 V AC (45-65 Hz) and DC networks. It monitors twelve channels via toroids with common alarm thresholds (high, medium, low) and detects insulation resistance from 200 Ω up to 250 kΩ. The unit performs automatic self-test at start-up and every five hours and mounts flush in a panel or on 35 mm DIN rail with IP54 front and IP20 case protection. Typical application is critical-power installations in marine, offshore, healthcare, infrastructure and industry where an unearthed neutral must be continuously monitored.

Technical Specifications

Manufacturer part number (MPN)IMDIFL12
EAN / GTIN3606489504830
Sales unitpcs
RangeVigilohm
Device short nameIFL12
Product or component typeInsulation fault locator
Earthing systemIT; HRG
ApplicationMarine and offshore; Industry; Infrastructure; Power generation; Port, airport, railway
Network sizeMedium
Electrical circuit typePower circuit
Network capacitanceLightly capacitive
Type of network1P + N; 3P; 3P + N
Network rated voltage0…1000 V - AC at 45...65 Hz; 0…1000 V - DC
Number of channels12
Alarm threshold settingAlarm: high, medium, low
Type of measurementNetwork insulation resistance, range: 200 Ohm...250 kOhm
Channel alarm threshold settingAlarm threshold: common to all feeders
Configurable filtering time5 s; 40 s
Response time1 s 1/5th of set filtering time; 8 s 1/5th of set filtering time
Power quality analysisTransient capture
Monitoring functionDetection of toroids connection automatic; Detection of toroids connection manual mode; Detection of IM400 injection current permanent
Self-testManual; Auto test at start and every 5h
Overvoltage categoryIII 300 V; II 600 V
IP degree of protectionCase: IP20; Front face: IP54
MaterialThermoplastic
Type of installationIndoor
Operating altitude<= 3000 m
Relative humidity5…92 %
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…85 °C
Pollution degree2
Mounting modeFlush-mounted (panel); Clip-on (DIN rail)
Mounting positionHorizontal; Vertical
Connections - terminalsPower supply: removable screw terminal block 0.2…2.5 mm²; Output relay: removable screw terminal block 0.2…2.5 mm²; Toroids inputs: removable screw terminal block 0.2…1.5 mm²
Product weight0.28 kg
Cut-out dimensions92 x 104 mm
Height110 mm
Width108 mm
Depth59 mm
Display typeWithout display
Local signallingYellow indicator light: insulation fault; Green/red indicator light: product status; Green indicator light: satisfactory insulation; Yellow flashing indicator light: transient fault; Green indicator light: configured threshold LED; Green indicator light: configured filtering LED; Yellow steady 1 LED per channel: insulation fault; Yellow flashing 1 LED per channel: transient fault/toroid disconnected
Signal contacts composition1 C/O standard
Signalling circuit voltage250 V - AC at 6 A; 48 V - DC at 1 A
Communication port protocol-
[Us] rated supply voltage100...300 V (LN) AC 50/60 Hz tolerance: +/- 15 %; 100...440 V AC 50/60 Hz tolerance: +/- 15 %; 80…120 V (LN) AC 400 Hz tolerance: +/- 15 %; 100...440 V DC tolerance: +/- 15 %
Power consumption in VA20 VA
Power consumption in W6 W
Overcurrent protection1 A
StandardsIEC 60364-4-41; IEC 61010-1; IEC 60364-5-51; IEC 61557-9; IEC 61557-15; IEC 61326-2-4; UL 61010-1
Product certificationsDNV-GL; CE; EAC; UL; cULus
Environmental characteristicExposure to damp heat not in service conforming to IEC 60068-2-30; Exposure to damp heat in service conforming to IEC 60068-2-56; Salt mist conforming to IEC 60068-2-52; Long-term storage class 1K22 conforming to IEC 60721-3-1; Transport class 2K11 conforming to IEC 60721-3-2; Stationary use at weather protected locations class 3K24 conforming to IEC 60721-3-3
Mechanical robustnessLong-term storage class 1M11 conforming to IEC 60721-3-1; Transport class 2M4 conforming to IEC 60721-3-2; Stationary use class 3M11 conforming to IEC 60721-3-3
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height10.500 cm
Package 1 Width13.500 cm
Package 1 Length18.500 cm
Package 1 Weight526.000 g
Unit Type of Package 2S03
Number of Units in Package 28
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight4.690 kg
Warranty (in months)18
Type of electric connectionScrew connection
Rated control supply voltage AC 50 Hz100–440 V
Rated control supply voltage AC 60 Hz100–440 V
Rated control supply voltage DC100–440 V
Voltage type for actuatingAC
With detachable clampsYes
FunctionFor mixed system
Rated voltage0–1000 V
Rated frequency45–65 Hz
Line capacity150 µF
Indication of insulation valueNo
Error registration possibleNo
Number of contacts as change-over contact1
Country of originIndia

Properties

MOQ1

Cross-References

Attached Documents