Schneider Electric cam changeover switch - 4-Pole - 60° - 32 A - screw mounting K30H004UP

Schneider Electric · Switchgear & Protection · Disconnect Switches · France · se.com
Part Number
K30H004UP  ·  HS 8536.50
Schneider Electric cam changeover switch - 4-Pole - 60° - 32 A - screw mounting K30H004UP

Schneider Electric K30H004UP Cam Switch 2 pos.0 still.4-pole.

Technical Specifications

Manufacturer part number (MPN)K30H004UP
EAN / GTIN3389110083422
Sales unitpcs
Package quantity30 pcs
Number of poles4
Range of productHarmony K
Product or component typeComplete cam switch
Component nameK30
[Ith] conventional free air thermal current32 A
Mounting locationFront
fixing mode4 holes
Cam switch head typeWith front plate 64 x 64 mm
Type of operatorBlack handle
Rotary handle padlockingWithout
Presentation of legendWith metallic legend, 1 - 0 - 2 black marking
Cam switch functionChangeover switch
ReturnWithout
Off positionWith Off position
Poles description4P
Switching positionsLeft: 0° - 300°; Right: 0° - 60°
IP degree of protectionIP40 conforming to IEC 60529
Switching angle60 °
[Ui] rated insulation voltage690 V (pollution degree 3) conforming to IEC 60947-1
Short-circuit current5000 A
Short-circuit protection50 A cartridge fuse, type gG
[Uimp] rated impulse withstand voltage6 kV conforming to EN 947-1; 6 kV conforming to IEC 947-1
Contact operationSlow-break
positive openingWith
Electrical connectionCaptive screw clamp terminals flexible, clamping capacity: 2 x 4 mm²; Captive screw clamp terminals solid, clamping capacity: 2 x 6 mm²
Tightening torque1.2 N.m
Switching capacity in mA11000 mA DC at 120 V 2 contact(s) for inductive load (T = 50 ms); 11000 mA DC at 180 V 3 contact(s) for inductive load (T = 50 ms); 11000 mA DC at 60 V 1 contact(s) for inductive load (T = 50 ms); 1200 mA DC at 220 V 1 contact(s) for resistive load (T = 1 ms); 1200 mA DC at 440 V 2 contact(s) for resistive load (T = 1 ms); 1200 mA DC at 660 V 3 contact(s) for resistive load (T = 1 ms); 16000 mA DC at 140 V 3 contact(s) for inductive load (T = 50 ms); 16000 mA DC at 48 V 1 contact(s) for inductive load (T = 50 ms); 16000 mA DC at 95 V 2 contact(s) for inductive load (T = 50 ms); 23000 mA DC at 120 V 2 contact(s) for resistive load (T = 1 ms); 23000 mA DC at 180 V 3 contact(s) for resistive load (T = 1 ms); 23000 mA DC at 60 V 1 contact(s) for resistive load (T = 1 ms); 25000 mA DC at 30 V 1 contact(s) for inductive load (T = 50 ms); 25000 mA DC at 60 V 2 contact(s) for inductive load (T = 50 ms); 25000 mA DC at 90 V 3 contact(s) for inductive load (T = 50 ms); 3200 mA DC at 110 V 1 contact(s) for inductive load (T = 50 ms); 3200 mA DC at 220 V 2 contact(s) for inductive load (T = 50 ms); 3200 mA DC at 330 V 3 contact(s) for inductive load (T = 50 ms); 32000 mA DC at 140 V 3 contact(s) for resistive load (T = 1 ms); 32000 mA DC at 24 V 1 contact(s) for inductive load (T = 50 ms); 32000 mA DC at 24 V 1 contact(s) for resistive load (T = 1 ms); 32000 mA DC at 48 V 1 contact(s) for resistive load (T = 1 ms); 32000 mA DC at 48 V 2 contact(s) for inductive load (T = 50 ms); 32000 mA DC at 48 V 2 contact(s) for resistive load (T = 1 ms); 32000 mA DC at 70 V 3 contact(s) for inductive load (T = 50 ms); 32000 mA DC at 70 V 3 contact(s) for resistive load (T = 1 ms); 32000 mA DC at 95 V 2 contact(s) for resistive load (T = 1 ms); 400 mA DC at 440 V 1 contact(s) for resistive load (T = 1 ms); 400 mA DC at 660 V 2 contact(s) for resistive load (T = 1 ms); 6500 mA DC at 110 V 1 contact(s) for resistive load (T = 1 ms); 6500 mA DC at 220 V 2 contact(s) for resistive load (T = 1 ms); 6500 mA DC at 330 V 3 contact(s) for resistive load (T = 1 ms)
Mechanical durability300000 cycles
CAD overall width64 mm
CAD overall height64 mm
CAD overall depth119 mm
Product weight0.485 kg
StandardsIEC 60947-3
Product certificationsCULus 120 V 2 hp 1 phase; CULus 240 V 5 hp 1 phase; CULus 240 V 5 hp 3 phases; CULus 480 V 20 hp 3 phases
Protective treatmentTC
Ambient air temperature for operation-25…55 °C
Ambient air temperature for storage-40…70 °C
Overvoltage categoryClass II conforming to IEC 60536; Class II conforming to NF C 20-030
Number of Units in Package 11
Number of Units in Package 230
Country of originAT
Warranty (in months)18
ModelReverser
Rated permanent current Iu32 A
With zero (off) positionYes
With retraction in 0-positionNo
Degree of protection (IP), front sideIP40
Type of electrical connection of main circuitScrew connection
Type of control elementLong rotary handle
Suitable for floor mountingNo
Suitable for front mountingYes
Suitable for distribution board installationNo
Suitable for intermediate mountingYes
Complete device in housingYes