| Manufacturer part number (MPN) | CJ2MCPU32 |
| EAN / GTIN | 4547648802031 |
| Sales unit | pcs |
| Width | 62 mm |
| Model | Modular |
| Height | 90 mm |
| Depth | 84.5 mm |
| With display | No |
| Suitable for safety functions | No |
| Voltage type (supply voltage) | AC/DC |
| Type of memory | FLASH |
| Memory size | 284 kByte |
| Processing time (1K, binary operation) | 0.04 ms |
| Supporting protocol for LON | No |
| Number of HW-interfaces industrial Ethernet | 1 |
| Number of HW-interfaces USB | 1 |
| Number of HW-interfaces other | 1 |
| With optical interface | No |
| Additional program memory possible | No |
| Supporting protocol for TCP/IP | Yes |
| Supporting protocol for ASI | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | No |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for other bus systems | No |
| Redundancy | No |
| Suitable for rail mounting | Yes |
| Explosion safety category for gas | None |
| Explosion safety category for dust | None |
| System accessory | No |
| Appendant operation agent (Ex ia) | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for INTERBUS-Safety | No |
| Front built-in possible | No |
| Rack-assembly possible | No |
| Wall mounting/direct mounting | No |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| IO link master | No |
| Max. number of time switches | 4090 |
| Performance level according to EN ISO 13849-1 | Level a |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for EtherNet/IP | Yes |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supply voltage AC 50 Hz | 85–264 V |
| Supply voltage AC 60 Hz | 85–264 V |
| Supply voltage DC | 24 V |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Mobile communications standard 3G (UMTS) | No |
| SIL according to IEC 61508 | None |
| Supporting protocol for IEC 61850 Ethernet | No |
| Supporting protocol for DNP3 | No |
| Supporting protocol for IEC 60870 | No |
| Supporting protocol for EtherCAT | No |
| Certified for UL hazardous location class I | No |
| Certified for UL hazardous location class II | No |
| Certified for UL hazardous location class III | No |
| Certified for UL hazardous location division 1 | No |
| Certified for UL hazardous location division 2 | No |
| Certified for UL hazardous location group A (acetylene) | No |
| Certified for UL hazardous location group B (hydrogen) | No |
| Certified for UL hazardous location group C (ethylene) | No |
| Certified for UL hazardous location group D (propane) | No |
| Certified for UL hazardous location group E (metal dusts) | No |
| Country of origin | Netherlands |