M18,ME,VINK,REFL3M,PNP,M12 PLU (E3RB-RP21 Oms)

Omron · Sensors & Instrumentation · Photoelectric Sensors
Part Number
E3RB-RP21 OMS  ·  HS 8536.90
M18,ME,VINK,REFL3M,PNP,M12 PLU (E3RB-RP21 Oms)

Omron E3RB-RP21 OMS Photocell, M18 angled, metal housing, red LED, reflector, 0.1-3m, PNP, L-ON/D-ON selectable, M12 plug.

Technical Specifications

Manufacturer part number (MPN)E3RB-RP21 OMS
EAN / GTIN4548583360853
Sales unitpcs
ConnectionM12 plug
Thread sizeM18
Output typePNP
Sensing methodRetro-reflective
Sensing distance3 m
Pre failure noticeNo
With time functionNo
Rated switching distance3000 mm
Max. switching distance3000 mm
Max. output current100 mA
With reflectorNo
Analogue output 0 V ... 10 VNo
Analogue output 0 mA ... 20 mANo
Analogue output 4 mA ... 20 mANo
Analogue output -10 V ... +10 VNo
With other analogue outputNo
Setting procedureManual adjustment
With communication interface analogueNo
With communication interface AS-InterfaceNo
With communication interface CANOpenNo
With communication interface DeviceNetNo
With communication interface EthernetNo
With communication interface INTERBUSNo
With communication interface PROFIBUSNo
With communication interface RS-232No
With communication interface RS-422No
With communication interface RS-485No
With communication interface SSDNo
With communication interface SSINo
Number of semiconductor outputs with signalling function1
Type of electric connectionConnector M12
Type of switching outputPNP
Type of switch functionProgrammable/configurable
Operation agent-safety classSafety class 0
Explosion safety category for gasNone
Explosion safety category for dustNone
Construction type housingCylinder, screw-thread
Diameter sensor18 mm
Length of sensor57 mm
Sensing modeLight-/dark switching
Material of optical surfacePlastic
Housing materialMetal
Min. reflector distance100 mm
Ambient temperature-25–55 °C
Response time0.5 ms
Switching frequency2000 Hz
Type of safety according to IEC 61496-11
Rated control supply voltage DC10–30 V
Voltage typeDC
With monitoring function downstream switching devicesNo
Laser protection classNone
Wavelength of the sensor624 nm
Type of lightPolarized red light
With restart blockageNo
Suitable for safety functionsNo
Degree of protection (IP)IP67
Country of originIndonesia

Properties