M12 male recept. A-cod. front (1276369)

Murrelektronik · Tools · Power Tools
Part Number
5424576306  ·  HS 8544.42
Image not available for this product

Murrelektronik 1276369 — M12 male recept. A-cod. front. Flange male M12, 4-pole Front mounting with multi-strand wire

Technical Specifications

Manufacturer part number (MPN)7000-13501-9710020
Distributor article number1276369
Model designationMSAFV-T971_0.2
EAN / GTIN4048879198738
HS code8544.42
EU customs tariff number85444290
US customs tariff number8544429090
Weight0.015 kg
Country of originDE
Cable length0.20 m
Side 1 - Family construction formM12
Side 1 - No. of poles4
Side 1 - CodingA
Side 1 - Gendermale
Side 1 - Mounting methodinserted, screwed
Side 1 - Threaded holeM12 x 1
Side 1 - Tightening torque0.6 Nm
Side 1 - Width across flatsSW14
Side 1 - MaterialZinc die-casting
Side 1 - Material contactCopper alloy
Side 1 - Coating contactgold plated
Side 1 - Degree of protection (EN IEC 60529)IP67
Electrical data - Conductor resistance (wire)58 Ω/km @ 20 °C
Electrical data | Supply - Operating voltage AC max.250 V
Electrical data | Supply - Operating voltage DC max.250 V
Supply - Current operating per contact max.4 A
Electrical data | Supply - Nominal voltage AC max.300 V
Installation | Connection - Mounting setM16 x 1.5
Device protection | Electrical - Protection NEMA6P, 4, 3
Electrical - Additional condition protection degreeinserted, screwed
Device protection | Electrical - Pollution Degree3
Electrical - Current load capacity (standard)to DIN VDE 0298-4
Electrical - Current load capacity min. wire6 A
Device protection | Electrical - Rated surge voltage2.5 kV
Device protection | Electrical - Isolation resistance20 MΩ × km
Electrical - Withstand voltage (wire - wire)1.5 kV @ 60 s
Electrical - Material group (IEC 60664-1)I
Mechanical data - Amount strands (wire)19
Mechanical data - Diameter of single wires0.15 mm
Mechanical data | Material data - Screw connectionZinc die-casting
Mechanical data | Material data - Coating of fittingnickel plated
Mechanical data | Material data - Locking materialZinc die-casting
Mechanical data | Material data - Coating lockingNickeled
Mechanical data | Material data - Material wire insulationPUR
Material data - Ingredient freeness wire insulationlead-free, CFC-free, halogen-free
Mechanical data | Material data - Material conductor wirecopper stranded wire, tinned
Mechanical data | Mounting data - Mounting methodSchraubgewinde
Mechanical data | Mounting data - Looking techniquesSchraubgewinde
Mechanical data | Mounting data - Cable weigth4.4 g/m
Climatic - Operating temperature min.-30 °C
Climatic - Operating temperature max.85 °C
Climatic - Operating temperature min. (static)-40 °C
Climatic - Operating temperature max. (static)-40 °C … 90 °C
Climatic - Operating temperature min. (dynamic)-25 °C
Climatic - Operating temperature max. (dynamic)-25 °C … 90 °C
Climatic - Additional condition temperature rangedepending on cable quality
Important installation notes - Note on bending radiusAttention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Important installation notes - Note on strain reliefProtect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Conformity - Product standardEN IEC 61076-2-101 (M12)
Approvals - UL 50EYes
General data | Cable - Cable identification971
General data | Cable - Cable weigth33 g/m
Structure | Cable - Stranding1 × 4 wires stranded
Structure | Cable - Wire arrangementBN, WH, BU, BK
Wire data | Cable - Material wire insulationPUR
Wire data | Cable - Amount wires4
Wire data | Cable - Outer diameter insulation1.3 mm ± 0.1 mm
Wire data | Cable - Conductor crosssection (wire)0.34 mm²
Wire data | Cable - Material conductor wirecopper stranded wire, tinned
Wire data | Cable - Core construction (wire)19 × 0.15 mm
Wire data | Cable - Ingredient freeness wire insulationlead-free, CFC-free, halogen-free
Electrical data | Cable - Conductor resistance (wire)58 Ω/km @ 20 °C
Electrical data | Cable - Nominal voltage max.300 V
Electrical data | Cable - Withstand voltage (wire - wire)1.5 kV @ 60 s
Cable - Current load capacity max. (wire)4.8 A
Electrical data | Cable - Current load capacity (standard)to DIN VDE 0298-4
Electrical data | Cable - Isolation resistance20 MΩ × km
Temperature range | Cable - Operating temperature (static)-40 °C … 90 °C
Cable - Operating temperature (dynamic)-25 °C … 90 °C
Resistances | Cable - Flame resistanceIEC 60332-1-2
Resistances | Cable - Oil resistanceIEC 60811-404
Resistances | Cable - Other resistancesresistant to hydrolysis, resistant to microbes
Resistances | Cable - Notesapplication-related testing
ETIM-9.0EC001855
ETIM-10.0EC001855
Packaging unit1
Product typeBuilt-in socket
Product groupAdapters, limit switches, sensor cables, and connector plugs
Number of poles4P
ConnectionM12
TypeHan straight
Cable dimension4 x 0.34 mm2
Carbon footprint (EPD)0.1696 kg CO2e per pcs
Manufacturer part number5424576306

Properties

MOQ1

Cross-References

Attached Documents