cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

RJ45 Basic male 0° / RJ45 Basic male 0° shielded TPE 4X2X26AWG SF/UTP CAT6A bu UL/CSA, CMR 0,3M (7700-74315-S4X0030)

Murrelektronik · Cables & Wiring · Data Cables
Part Number
7700-74315-S4X0030  ·  HS 8544.42
RJ45 Basic male 0° / RJ45 Basic male 0° shielded TPE 4X2X26AWG SF/UTP CAT6A bu UL/CSA, CMR 0,3M (7700-74315-S4X0030)

Murrelektronik 7700-74315-S4X0030 — RJ45 Basic male 0° / RJ45 Basic male 0° shielded TPE 4x2x26AWG SF/UTP CAT6a bu UL/CSA, CMR 0,3m. USA Ethernet CAT6A Male straight – male straight RJ45 – RJ45, 8-pole Shielded without cable sleeves

Technical Specifications

Manufacturer part number (MPN)7700-74315-S4X0030
Model designationMSRAL0-RA-8p8c_S4X_0.3
EAN / GTIN4048879794718
HS code8544.42
EU customs tariff number85444210
US customs tariff number8544422000
Weight0.040 kg
Country of originHU
Sales unitpcs
Cable length0.30 m
Side 1 - Family construction formRJ45
Side 1 - No. of poles8
Side 1 - Gendermale
Side 1 - Mounting methodinserted
Side 1 - Cable outletstraight
Side 1 - Degree of protection (EN IEC 60529)IP20
Side 2 - Family construction formRJ45
Side 2 - No. of poles8
Side 2 - Gendermale
Side 2 - Mounting methodinserted
Side 2 - Cable outletstraight
Side 2 - Degree of protection (EN IEC 60529)IP20
Electrical data | Supply - Operating voltage DC max.60 V
Electrical data | Supply - Operating current max.1.5 A
Industrial Communication - Data transmission rate max.10 Gbit/s
Industrial Communication - Transfer parametersCAT6, Class EA (ISO/IEC 11801:2002), (EN 50173-1)
Diagnostics - Status indication LEDNo
Installation | Pin assignment - Configurationfully used
Electrical - Degree of protection (EN IEC 60529)IP20
Electrical - Additional condition protection degreeinserted
Device protection | Electrical - Pollution Degree3
Device protection | Electrical - Rated surge voltage1 kV
Electrical - Material group (IEC 60664-1)I
Mechanical data - Contour for corrugated hosewithout
Mechanical data | Material data - housingPUR
Mechanical data | Material data - Locking materialPA
Mechanical data | Mounting data - Looking techniquesSnap-in connector
Climatic - Operating temperature min.-25 °C
Climatic - Operating temperature max.85 °C
Climatic - Additional condition temperature rangedepending on cable quality
Important installation notes - Note on bending radiusAttention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Important installation notes - Note on strain reliefProtect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
General data | Cable - Cable identificationS4X
General data | Cable - Function cableData
General data | Cable - Cable weigth59.53 g/m
General data | Cable - UL AWM Style2463 / 11547
Structure | Cable - Stranding4 × 2 wires stranded
Structure | Cable - Stranding (type 2)1 × 4 stranding combinations stranded around insulation element
Structure | Cable - BandingFoil
Structure | Cable - FillerInsulation element
Structure | Cable - Wire arrangement(OGWH, OG), (BUWH, BU), (BNWH, BN), (GNWH, GN)
Structure | Cable - Cable typeIndustrial Ethernet Profinet Typ C, CAT6A
Wire data | Cable - Material wire insulationHDPE
Wire data | Cable - Amount wires8
Wire data | Cable - Outer diameter insulation0.9 mm ± 0.05 mm
Wire data | Cable - Conductor crosssection (wire)26 AWG
Wire data | Cable - Material conductor wirecopper stranded wire, tinned
Wire data | Cable - Core construction (wire)7 x 34 AWG
Wire data | Cable - Ingredient freeness wire insulationlead-free, CFC-free
Jacket data | Cable - Material jacketTPE
Jacket data | Cable - Outer-diameter (jacket)7.4 mm ± 5 %
Jacket data | Cable - Jacket Colorblue / RAL 5018
Jacket data | Cable - Freedom from ingredients (jacket)lead-free, CFC-free
Electrical data | Cable - Conductor resistance (wire)212 Ω/km @ 20 °C
Electrical data | Cable - Nominal voltage max.600 V
Electrical data | Cable - Withstand voltage (wire - wire)1.5 kV @ 2 s
Cable - Withstand voltage (wire - jacket)1.5 kV @ 2 s
Cable - Current load capacity max. (wire)2 A
Electrical data | Cable - Current load capacity (standard)to DIN VDE 0298-4
Cable - Electrical capacity line constant (wire - wire)84.848 pF/km
Electrical data | Cable - Characteristic impedance100 Ω
Electrical data | Cable - Loop resistance424 Ω/km
Electrical data | Cable - Cable length max.66 m
Temperature range | Cable - Operating temperature (static)-40 °C … 80 °C
Cable - Operating temperature (dynamic)-40 °C … 80 °C
Cable - Operating temperature (drag chain)-40 °C … 80 °C
Resistances | Cable - Flame resistanceUL 1581 § 1060, UL 1581 § 1061, UL 1581 § 1080, IEC 60332-1-2
Resistances | Cable - Oil resistanceIEC 60811-404, IRM 902
Resistances | Cable - UV resistanceUL 1581 § 1200
Resistances | Cable - Notesapplication-related testing
Installation | Cable - Bending radius (fixed)4 × Outer diameter
Installation | Cable - Bending radius (dynamic)18 × Outer diameter
Installation | Cable - No. of bending cycles (C-track)35 Mio. @ 25 °C
Installation | Cable - Traversing distance (C-track)0.6 m @ 25 °C
Installation | Cable - Travel speed (C-track)1.2 m/s @ 25 °C
Installation | Cable - Acceleration (C-track)2.4 m/s² @ 25 °C
Installation | Cable - No. of torsion cycles3 Mio. @ 25 °C
Installation | Cable - Torsion stress± 270 °/m
Installation | Cable - Torsion speed60 cycles/min @ 25 °C
ETIM-5.0EC002599
ETIM-6.0EC002599
ETIM-7.0EC002599
ETIM-8.0EC002599
ETIM-9.0EC002599
ETIM-10.0EC002599
Packaging unit1
ECLASS 14.027060307

Properties

MOQ1

Cross-References

Attached Documents