cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

RJ45 male 0° / RJ45 male 0° shielded FRNC/LS0H 4X2XAWG27 shielded rd UL 10M (7000-74711-5781000)

Murrelektronik · Cables & Wiring · Data Cables
Part Number
7000-74711-5781000  ·  HS 8544.42
RJ45 male 0° / RJ45 male 0° shielded FRNC/LS0H 4X2XAWG27 shielded rd UL 10M (7000-74711-5781000)

Murrelektronik 7000-74711-5781000 — RJ45 male 0° / RJ45 male 0° shielded FRNC/LS0H 4x2xAWG27 shielded rd UL 10m. Ethernet CAT6A Male straight – male straight RJ45 – RJ45, 8-pole Shielded without cable sleeves

Technical Specifications

Manufacturer part number (MPN)7000-74711-5781000
Model designationMSRAL0-RA-8p8c578_10.0
EAN / GTIN4048879594752
HS code8544.42
EU customs tariff number85444210
US customs tariff number8544422000
Weight0.481 kg
Country of originHU
Sales unitpcs
Cable length10.00 m
Side 1 - Family construction formRJ45
Side 1 - No. of poles8
Side 1 - Gendermale
Side 1 - Mounting methodinserted
Side 1 - Cable outletstraight
Side 1 - Degree of protection (EN IEC 60529)IP20
Side 2 - Family construction formRJ45
Side 2 - No. of poles8
Side 2 - Gendermale
Side 2 - Mounting methodinserted
Side 2 - Cable outletstraight
Side 2 - Degree of protection (EN IEC 60529)IP20
Electrical data | Supply - Operating voltage DC max.60 V
Supply - Current operating per contact max.1.5 A
Supply - Operating voltage DC max. (UL-listed)25 V
Industrial Communication - Data transmission rate max.10 Gbit/s
Industrial Communication - Transfer parametersCAT6A
Diagnostics - Status indication LEDNo
Electrical - Degree of protection (EN IEC 60529)IP20
Electrical - Additional condition protection degreeinserted
Device protection | Electrical - Pollution Degree3
Device protection | Electrical - Rated surge voltage1 kV
Electrical - Material group (IEC 60664-1)I
Mechanical data - Contour for corrugated hosewithout
Mechanical data | Material data - housingPUR
Mechanical data | Material data - Locking materialPA
Mechanical data | Mounting data - Looking techniquesSnap-in connector
Climatic - Operating temperature min.-25 °C
Climatic - Operating temperature max.85 °C
Climatic - Additional condition temperature rangedepending on cable quality
Important installation notes - Note on bending radiusAttention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Important installation notes - Note on strain reliefProtect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
General data | Cable - Cable identification578
General data | Cable - Cable weigth43 g/m
Structure | Cable - Stranding4 × 2 wires stranded
Structure | Cable - Stranding (type 2)1 × 4 stranding combinations stranded
Structure | Cable - Cable shielding (type)copper braiding, bare
Structure | Cable - Pair shielding (type)Metal foil
Structure | Cable - BandingFoil
Structure | Cable - Wire arrangement(WH, BN), (WH, BU), (WH, OG), (WH, GN)
Structure | Cable - Shieldshielded
Structure | Cable - Cable typeIndustrial Ethernet CAT7
Wire data | Cable - Material wire insulationcell polyethylene
Wire data | Cable - Amount wires8
Wire data | Cable - Outer diameter insulation1 mm ± 0.05 mm
Wire data | Cable - Conductor crosssection (wire)27 AWG
Wire data | Cable - Material conductor wireStranded copper wire, bare
Wire data | Cable - Core construction (wire)7 x 35 AWG
Wire data | Cable - Ingredient freeness wire insulationlead-free, CFC-free, halogen-free
Jacket data | Cable - Material jacketFRNC
Jacket data | Cable - Outer-diameter (jacket)6 mm ± 5 %
Jacket data | Cable - Jacket Colorred / RAL 3000
Jacket data | Cable - Freedom from ingredients (jacket)lead-free, CFC-free, halogen-free
Shield | Cable - Cable shielding (type)copper braiding, bare
Shield | Cable - Pair shielding (type)Metal foil
Electrical data | Cable - Nominal voltage max.125 V
Electrical data | Cable - Withstand voltage (wire - wire)2.5 kV @ 2 s
Cable - Withstand voltage (wire - jacket)2.5 kV @ 2 s
Cable - Withstand voltage (wire - shield)2.5 kV @ 2 s
Cable - Current load capacity max. (wire)1.3 A
Electrical data | Cable - Current load capacity (standard)to DIN VDE 0298-4
Electrical data | Cable - Electric capacitance44.000 pF/km
Electrical data | Cable - Isolation resistance5 GΩ × km
Electrical data | Cable - Characteristic impedance100 Ω ± 5 % @ 100 MHz
Temperature range | Cable - Operating temperature (static)-20 °C … 60 °C
Cable - Operating temperature (dynamic)-20 °C … 60 °C
Resistances | Cable - Flame resistanceIEC 60332-1-2, IEC 60332-2-2, IEC 60332-3-24, IEC 60754-2, IEC 61034-1, IEC 61034-2, UL 2556 § 9.4
Resistances | Cable - Notesapplication-related testing
Installation | Cable - Bending radius (dynamic)4 × Outer diameter
ETIM-5.0EC002599
ETIM-6.0EC002599
ETIM-7.0EC002599
ETIM-8.0EC002599
ETIM-9.0EC002599
ETIM-10.0EC002599
Packaging unit1
ECLASS 14.027060307

Properties

MOQ1

Cross-References

Attached Documents