| Manufacturer part number (MPN) | 7000-74701-7770300 |
| Model designation | MSRAL0-RA-8p4c777_3.0 |
| EAN / GTIN | 4048879569972 |
| HS code | 8544.42 |
| EU customs tariff number | 85444210 |
| US customs tariff number | 8544422000 |
| Weight | 0.278 kg |
| Country of origin | HU |
| Sales unit | pcs |
| Cable length | 3.00 m |
| Side 1 - Family construction form | RJ45 |
| Side 1 - No. of poles | 4 |
| Side 1 - Gender | male |
| Side 1 - Mounting method | inserted |
| Side 1 - Cable outlet | straight |
| Side 1 - Degree of protection (EN IEC 60529) | IP20 |
| Side 2 - Family construction form | RJ45 |
| Side 2 - No. of poles | 4 |
| Side 2 - Gender | male |
| Side 2 - Mounting method | inserted |
| Side 2 - Cable outlet | straight |
| Side 2 - Degree of protection (EN IEC 60529) | IP20 |
| Electrical data | Supply - Operating voltage DC max. | 60 V |
| Supply - Current operating per contact max. | 1.76 A |
| Industrial Communication - Data transmission rate max. | 100 Mbit/s |
| Industrial Communication - Transfer parameters | CAT5e, Class D (ISO/IEC 11801:2002), (EN 50173-1) |
| Industrial communication | Ethernet functionality - duplex | Full duplex |
| Diagnostics - Status indication LED | No |
| Electrical - Degree of protection (EN IEC 60529) | IP20 |
| Electrical - Additional condition protection degree | inserted |
| Device protection | Electrical - Pollution Degree | 3 |
| Device protection | Electrical - Rated surge voltage | 1 kV |
| Electrical - Material group (IEC 60664-1) | I |
| Mechanical data - Contour for corrugated hose | without |
| Mechanical data | Material data - housing | PUR |
| Mechanical data | Material data - Locking material | PA |
| Mechanical data | Mounting data - Looking techniques | Snap-in connector |
| Climatic - Operating temperature min. | -25 °C |
| Climatic - Operating temperature max. | 85 °C |
| Climatic - Additional condition temperature range | depending on cable quality |
| Important installation notes - Note on bending radius | Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces. |
| Important installation notes - Note on strain relief | Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties. |
| General data | Cable - Cable identification | 777 |
| General data | Cable - Cable weigth | 28.8 g/m |
| Structure | Cable - Stranding | 2 Wires |
| Structure | Cable - Stranding (type 2) | 1 Stranded joints |
| Structure | Cable - Wire arrangement | WH, BU, WH, OG |
| Wire data | Cable - Material wire insulation | FRNC |
| Wire data | Cable - Amount wires | 4 |
| Wire data | Cable - Conductor crosssection (wire) | 26 AWG |
| Wire data | Cable - Material conductor wire | Stranded copper wire, bare |
| Jacket data | Cable - Material jacket | FRNC |
| Jacket data | Cable - Outer-diameter (jacket) | 5 mm ± 5 % |
| Jacket data | Cable - Jacket Color | gray / RAL 7040 |
| Temperature range | Cable - Operating temperature (static) | -20 °C … 60 °C |
| Cable - Operating temperature (dynamic) | -20 °C … 60 °C |
| Installation | Cable - Bending radius (fixed) | 7.5 × Outer diameter |
| ETIM-5.0 | EC002599 |
| ETIM-6.0 | EC002599 |
| ETIM-7.0 | EC002599 |
| ETIM-8.0 | EC002599 |
| ETIM-9.0 | EC002599 |
| ETIM-10.0 | EC002599 |
| Packaging unit | 1 |
| ECLASS 14.0 | 27060307 |