M12 male 0° / M12 female 0° A-cod. PUR 4X0.34 gy UL/CSA+drag ch. 2M (7000-40021-2340200)

Murrelektronik · Cables & Wiring · Sensor Cables
Part Number
7000-40021-2340200  ·  HS 8544.42
Image not available for this product

Murrelektronik 7000-40021-2340200 M12 straight male for M12 straight female, PUR 4X0.34 UL/CSA, drag ch 2m.

Technical Specifications

Manufacturer part number (MPN)7000-40021-2340200
Model designationMSBL0-A-T234_2.0
EAN / GTIN4048879184151
HS code8544.42
EU customs tariff number85444290
US customs tariff number8544429090
Weight0.099 kg
Country of originDE
Sales unitpcs
Cable length2.00 m
Side 1 - Family construction formM12
Side 1 - No. of poles4
Side 1 - CodingA
Side 1 - Gendermale
Side 1 - Mounting methodinserted, screwed
Side 1 - Threaded holeM12 x 1
Side 1 - Tightening torque0.6 Nm
Side 1 - Width across flatsSW13
Side 1 - Cable outletstraight
Side 1 - suitable for corrugated tube (internal Ø)10 mm
Side 1 - MaterialPUR
Side 1 - Material contactCopper alloy
Side 1 - Coating contactgold plated
Side 1 - Degree of protection (EN IEC 60529)IP67, IP66K, IP65
Side 2 - Family construction formM12
Side 2 - No. of poles4
Side 2 - CodingA
Side 2 - Genderfemale
Side 2 - Mounting methodinserted, screwed
Side 2 - Threaded holeM12 x 1
Side 2 - Tightening torque0.6 Nm
Side 2 - Width across flatsSW13
Side 2 - Cable outletstraight
Side 2 - suitable for corrugated tube (internal Ø)10 mm
Side 2 - MaterialPUR
Side 2 - Material contactCopper alloy
Side 2 - Coating contactgold plated
Side 2 - Degree of protection (EN IEC 60529)IP67, IP66K, IP65
Electrical data | Supply - Operating voltage AC max.250 V
Electrical data | Supply - Operating voltage DC max.250 V
Supply - Current operating per contact max.4 A
Diagnostics - Status indication LEDNo
Installation | Connection - Mounting setM12 x 1
Electrical - Additional condition protection degreeinserted, screwed
Device protection | Electrical - Pollution Degree3
Device protection | Electrical - Rated surge voltage2.5 kV
Electrical - Material group (IEC 60664-1)I
Mechanical data | Material data - Color contact carriergreen
Mechanical data | Material data - Screw connectionZinc die-casting
Mechanical data | Material data - Coating of fittingnickel plated
Mechanical data | Material data - Locking materialZinc die-casting
Mechanical data | Material data - Coating lockingNickeled
Mechanical data | Mounting data - Mounting methodinserted, screwed, Shaking protection
Climatic - Operating temperature min.-30 °C
Climatic - Operating temperature max.85 °C
Climatic - Additional condition temperature rangedepending on cable quality
Important installation notes - Note on bending radiusAttention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Important installation notes - Note on strain reliefProtect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Conformity - Product standardEN IEC 61076-2-101 (M12)
General data | Cable - Cable identification234
General data | Cable - Cable Type3
General data | Cable - Cable weigth33 g/m
General data | Cable - UL AWM Style20549 / 10493
Structure | Cable - Stranding1 × 4 wires stranded
Structure | Cable - Wire arrangementBN, BK, BU, WH
Wire data | Cable - Material wire insulationPP
Wire data | Cable - Amount wires4
Wire data | Cable - Outer diameter insulation1.25 mm ± 0.05 mm
Wire data | Cable - Conductor crosssection (wire)0.34 mm²
Wire data | Cable - Material conductor wireStranded copper wire, bare
Wire data | Cable - Core construction (wire)42 × 0.1 mm
Wire data | Cable - Ingredient freeness wire insulationlead-free, cadmium-free, CFC-free, halogen-free, silicone-free
Jacket data | Cable - Material jacketPUR
Jacket data | Cable - Outer-diameter (jacket)4.5 mm ± 5 %
Jacket data | Cable - Jacket Colorgray / RAL 7040
Jacket data | Cable - Freedom from ingredients (jacket)lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
Jacket data | Cable - Material property (jacket)abrasion-resistant, low adhesion, good machinability, matte
Electrical data | Cable - Conductor resistance (wire)57 Ω/km @ 20 °C
Electrical data | Cable - Nominal voltage max.300 V
Electrical data | Cable - Withstand voltage (wire - wire)2.5 kV @ 60 s
Cable - Withstand voltage (wire - jacket)2.5 kV @ 60 s
Cable - Current load capacity max. (wire)4.8 A
Electrical data | Cable - Current load capacity (standard)to DIN VDE 0298-4
Temperature range | Cable - Operating temperature (static)-40 °C … 80 °C / 90 °C @ 10000 h Operation
Cable - Operating temperature (dynamic)-25 °C … 80 °C / 90 °C @ 10000 h Operation
Cable - Operating temperature (drag chain)-25 °C … 80 °C / 90 °C @ 10000 h Operation
Resistances | Cable - Flame resistanceUL 1581 § 1090, CSA FT2, IEC 60332-2-2
Resistances | Cable - Oil resistanceIEC 60811-404
Resistances | Cable - Chemical resistancegood
Resistances | Cable - Other resistancesgood resistance to gasoline, resistant to hydrolysis, resistant to microbes
Resistances | Cable - Notesapplication-related testing
Installation | Cable - Bending radius (fixed)5 × Outer diameter
Installation | Cable - Bending radius (dynamic)10 × Outer diameter
Installation | Cable - No. of bending cycles (C-track)10 Mio. @ 25 °C
Installation | Cable - Traversing distance (C-track)10 m @ 25 °C | horizontal
Installation | Cable - Travel speed (C-track)3 m/s @ 25 °C
Installation | Cable - Acceleration (C-track)10 m/s² @ 25 °C
Installation | Cable - No. of torsion cycles5 Mio.
Installation | Cable - Torsion stress± 360 °/m
Installation | Cable - Torsion speed35 cycles/min
ETIM-9.0EC001855
ETIM-10.0EC001855
Packaging unit1

Properties

MOQ1

Cross-References