EOL - M12 male 0° / M12 female 0° A-cod. PUR 4X0.34 gy UL/CSA 0.3M (7000-40021-2240030)

Murrelektronik · Cables & Wiring · Sensor Cables
Part Number
7000-40021-2240030  ·  HS 8544.42
Image not available for this product

Murrelektronik 7000-40021-2240030 — EOL - M12 male 0° / M12 female 0° A-cod. PUR 4x0.34 gy UL/CSA 0.3m. ⚠ NOTICE ⚠ PRODUCT IS DISCONTINUED. PLEASE HAVE A LOOK AT THE ALTERNATIVE PRODUCTS.

Technical Specifications

Manufacturer part number (MPN)7000-40021-2240030
Model designationMSBL0-A-T224_0.3
EAN / GTIN4048879184441
HS code8544.42
EU customs tariff number85444290
Weight0.032 kg
Country of originDE
Sales unitpcs
Packaging unit1
Cable length0.3 m
Side 1 - Tightening torque0.6 Nm
Side 1 - Mounting methodinserted, screwed
Side 1 - Family construction formM12
Side 1 - ThreadM12 x 1
Side 1 - suitable for corrugated tube (internal Ø)10 mm
Side 1 - Gendermale
Side 1 - Cable outletstraight
Side 1 - CodingA
Side 1 - MaterialPUR
Side 1 - No. of poles4
Side 1 - Width across flatsSW13
Side 1 - Degree of protection (EN IEC 60529)IP65, IP66K, IP67
Side 2 - Tightening torque0.6 Nm
Side 2 - Mounting methodinserted, screwed
Side 2 - Family construction formM12
Side 2 - ThreadM12 x 1
Side 2 - Genderfemale
Side 2 - suitable for corrugated tube (internal Ø)10 mm
Side 2 - Cable outletstraight
Side 2 - CodingA
Side 2 - MaterialPUR
Side 2 - No. of poles4
Side 2 - Width across flatsSW13
Side 2 - Degree of protection (EN IEC 60529)IP65, IP66K, IP67
Electrical data | Supply - Operating voltage AC max.250 V
Electrical data | Supply - Operating voltage DC max.250 V
Supply - Current operating per contact max.4 A
Diagnostics - Status indication LEDno
Installation | Connection - Mounting setM12 x 1
Electrical - Additional condition protection degreeinserted, screwed
Device protection | Electrical - Pollution Degree3
Device protection | Electrical - Rated surge voltage2.5 kV
Electrical - Material group (IEC 60664-1)I
Mechanical data | Material data - Coating lockingNickeled
Mechanical data | Material data - Coating of fittingnickel plated
Mechanical data | Material data - Color contact carriergreen
Mechanical data | Material data - Locking materialZinc die-casting
Material data - Material screw connectionZinc die-casting
Mechanical data | Mounting data - Mounting methodinserted, screwed, Shaking protection
Climatic - Operating temperature min.-30 °C
Climatic - Operating temperature max.85 °C
Climatic - Additional condition temperature rangedepending on cable quality
Important installation notes - Note on strain reliefProtect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Important installation notes - Note on bending radiusAttention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Conformity - Product standardDIN EN 61076-2-101 (M12)
Cable - Cable identification224
Cable - Cable Type2 (PUR/PVC)
Cable - Approval (cable)UL (AWM-Style 20549/1731), CSA; CE conform
Cable - Cable weight [g/m]42.68 g
Cable - Material wireCu wire, bare
Cable - Resistor (core)max. 57 Ω/km (20 °C)
Cable - Single wire Ø (core)0.1 mm
Cable - Construction (core)42× 0.1 mm (multi-strand wire class 6)
Cable - Diameter (core)4× 0.34 mm²
Cable - AWGsimilar to AWG 22
Cable - Material wire isolationPVC
Cable - Material property wire insulationCFC-, cadmium-, silicone- and lead-free
Cable - Shore hardness wire isolation43 ±5 D
Cable - Wire-Ø incl. isolation1.25 mm ±5%
Cable - Color/numbering of wiresbr, bk, bl, wh
Cable - Stranding combination4 wires twisted
Cable - Shieldno
Cable - Material jacketPUR/PVC
Cable - Material property (jacket)CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis and microbial resistant
Cable - Shore hardness jacket80 ±5 A (PVC-under jacket); 85 ±5 A (PUR-jacket)
Cable - Outer-Ø (jacket)4.6 mm ±5%
Cable - Color jacketgray
Cable - chemical resistancegood resistance to oil, gasoline and chemicals
Cable - Nominal voltageUL 300 V AC
Cable - Test voltage2000 V AC
Cable - Current load capacityto DIN VDE 0298-4
Cable - Temperature range (fixed)-30...+80 °C
Cable - Temperature range (mobile)-5...+80 °C
Cable - Bending radius (fixed)10× outer Ø
Cable - Bending radius (dynamic)15× outer Ø
Cable - No. of bending cycles (C-track)max. 2 Mio. (25 °C)
Cable - Travel speed (C-track)max. 3.3 m/s
Cable - Acceleration (C-track)max. 5 m/s²
ETIM-5.0EC001855
ECLASS 12.027060311

Properties

MOQ1

Cross-References

Attached Documents